    DESCRIPTION YORK Sunline 2000 Heat Pumps are convertible single package units with a common cabinet and common roof curb for the 3, 4 and 5 ton sizes. The units were designed for residential and light commercial applications. They can easily be installed on a roof curb, slab, roof jack or frame. All units are self--contained and assembled on rigid ...

  • York SUNLINE 2000 48 - page 2

    SYSTEM PROTECTION -- Crankcase heaters and internal compressor protection are standard on all compressors. Every unit has a liquid line filter--drier , low pressure switch, high pressure switch and high temperature switch to protect all system components. A suction line freezestat is supplied on all three--phase units to protect against loss of cha ...

  • York SUNLINE 2000 48 - page 3

    036-21564-002-A-0404 Unitary Products Group 3 MODELS BCH 036 048 060 SUPPL Y AIR BLOWER CENTRIFUGAL BLOWER (Dia. x Wd. in.) 12 x 10 12 x 10 12 x 10 F AN MOTOR HP (DIRECT -DRIVE) 1 F AN MOTOR HP (BEL T -DRIVE) 1.5 1.5 1.5 INDOOR COIL ROWS DEEP 4 3 3 FINS PER INCH 16 15 15 F ACE AREA (Sq. Ft.) 4.3 5.1 5.1 OUTDOOR FA N PROPELLER DIA. (in.) 22 22 24 F ...

  • York SUNLINE 2000 48 - page 4

    036-21564-002-A-0404 4 Unitary Products Group COOLING CAP ACITIES - 3 TON (BCH036) Air On Indoor Coil T emperature of Air on Outdoor Coil 85 ° F9 5 ° F To t a l Cap. 1 MBH Power Input 2 KW Sensible Capacity 1 , MBH To t a l Cap. 1 MBH Power Input 2 KW Sensible Capacity 1 , MBH CFM WB ° F Entering Dry Bulb, ° F Entering Dry Bulb, ° F 86 83 80 7 ...

  • York SUNLINE 2000 48 - page 5

    036-21564-002-A-0404 Unitary Products Group 5 COOLING CAP ACITIES - 4 TON (BCH048) Air On Indoor Coil T emperature of Air on Outdoor Coil 85 ° F9 5 ° F To t a l Cap. 1 MBH Power Input 2 KW Sensible Capacity 1 , MBH To t a l Cap. 1 MBH Power Input 2 KW Sensible Capacity 1 , MBH CFM WB ° F Entering Dry Bulb, ° F Entering Dry Bulb, ° F 86 83 80 7 ...

  • York SUNLINE 2000 48 - page 6

    036-21564-002-A-0404 6 Unitary Products Group COOLING CAP ACITIES - 5 TON (BCH060) Air On Indoor Coil T emperature of Air on Outdoor Coil 85 ° F9 5 ° F To t a l Cap. 1 MBH Power Input 2 KW Sensible Capacity 1 , MBH To t a l Cap. 1 MBH Power Input 2 KW Sensible Capacity 1 , MBH CFM WB ° F Entering Dry Bulb, ° F Entering Dry Bulb, ° F 86 83 80 7 ...

  • York SUNLINE 2000 48 - page 7

    036-21564-002-A-0404 Unitary Products Group 7 HEA TING CAP ACITIES BCH036 CFM RET . AIR CAP OUTDOOR AIR TEMPERATURE, ° F (72% RH) ° F & K W - 1 0 0 1 02 03 04 05 06 0 1750 55 MBH 13.1 16.4 23.5 29.1 30.2 41.7 47.0 48.2 KW 2.9 3.0 3.2 3.3 3.5 3.7 3.8 3.9 70 MBH 1 1.9 15.0 21.5 26.7 27.7 38.2 43.1 44.1 KW 3.0 3.1 3.4 3.4 3.6 3.8 3.9 4.1 80 MBH ...

  • York SUNLINE 2000 48 - page 8

    036-21564-002-A-0404 8 Unitary Products Group SUPPL Y AIR BLOWER PERFORMANCE - BCH036 & 048 with Belt-Drive MODEL BCH AIR FLOW CFM Available External S tatic Pressure - IWG* 0.20 0.30 0.40 0.50 0.60 0.70 0.80 RPM W atts RPM W atts RPM W atts RPM Watt s RPM W atts RPM W atts RPM W atts 048 2000 843 860 880 925 919 1005 956 1065 993 1 145 1030 1 ...

  • York SUNLINE 2000 48 - page 9

    036-21564-002-A-0404 Unitary Products Group 9 SUPPL Y AIR BLOWER PERFORMANCE - BCH036, 048 & 060 with Direct-Drive SUPPL Y AIR BLOWER PERFORMANCE - BCH060 with Belt-Drive MODEL BCH AIR FLOW CFM Available External S tatic Pressure - IWG* 0.20 0.30 0.40 0.50 0.60 0.70 0.80 RPM W atts RPM W atts RPM W atts RPM Watt s RPM W atts RPM W atts RPM W at ...

  • York SUNLINE 2000 48 - page 10

    036-21564-002-A-0404 10 Unitary Products Group HEA TER / CFM LIMIT ATIONS HEA TER SIZE NOM. KW VOL TAGE 1 UNIT MODEL SIZE, NOMINAL TONS 345 MINIMUM SUPPL Y AIR CFM 5 7 10 15 20 30 208 / 230-1-60 1,100 1,100 1,200 1,200 1,300 2 - 1,300 1,300 1,300 1,300 1,300 2 - 1,600 1,600 1,600 1,600 1,600 1,600 5 7 10 15 20 30 208 / 230-3-60 1,100 1,100 1,200 1, ...

  • York SUNLINE 2000 48 - page 11

    036-21564-002-A-0404 Unitary Products Group 11 ELECTRICAL DA T A - Basic Unit (Direct-Drive) MODEL BCH POWER SUP - PL Y VOL TAGE LIMIT ATIONS (SEE NOTE 1) COMPRESSOR OUTDOOR FA N MOTOR, FLA SUPPL Y AIR BLOWER MOTOR, FLA MINIMUM CIRCUIT AMP ACITY MAX. FUSE SIZE, (SEE NOTE 2) AMPS MAX. HACR BREAKER SIZE, AMPS MIN. MAX. RLA LRA 036 208/230-1-60 208/23 ...

  • York SUNLINE 2000 48 - page 12

    036-21564-002-A-0404 12 Unitary Products Group MODEL BCH POWER SUPPL Y HEA TER ACCESSORY MODEL NUMBER SUPPL Y AIR BLOWER MOTOR FLA ELECTRIC HEA TERS MINIMUM CIRCUIT AMP ACITY MAX. FUSE SIZE 1 AMPS MAX. SIZE HACR 2 BREAKER AMPS KW ST AGES TO T A L AMPS 048 208-1-60 2CE04500506 2CE04500706 2CE04501006 2CE04501506 2CE04502006 5.0 4.0 5.6 8.0 1 1.9 15. ...

  • York SUNLINE 2000 48 - page 13

    036-21564-002-A-0404 Unitary Products Group 13 ELECTRICAL DA T A - Basic Unit (Belt-Drive) MODEL BCH POWER SUP - PL Y VOL TAGE LIMIT ATIONS (SEE NOTE 1) COMPRESSOR OUTDOOR FA N MOTOR, FLA SUPPL Y AIR BLOWER MOTOR, FLA MINIMUM CIRCUIT AMP ACITY MAX. FUSE SIZE, (SEE NOTE 2) AMPS MAX. HACR BREAKER SIZE, AMPS MIN. MAX. RLA LRA 036 208/230-1-60 208/230- ...

  • York SUNLINE 2000 48 - page 14

    036-21564-002-A-0404 14 Unitary Products Group MODEL BCH POWER SUPPL Y HEA TER ACCESSORY MODEL NUMBER SUPPL Y AIR BLOWER MOTOR FLA ELECTRIC HEA TERS MINIMUM CIRCUIT AMP ACITY MAX. FUSE SIZE 1 AMPS MAX. SIZE HACR 2 BREAKER AMPS KW ST AGES TO T A L AMPS 048 208-1-60 2CE04500525* 2CE04500725* 2CE04501025 2CE04501525 2CE04502025 8.6 4.0 5.6 8.0 1 1.9 1 ...

  • York SUNLINE 2000 48 - page 15

    036-21564-002-A-0404 Unitary Products Group 15 CLEARANCES Front 24" Back 12" (Less Economizer) 36" (With Economizer or Fixed Air/Motorized Air Damper) Left Side (Filter Access) 24" (Less Economizer) 36" (With Economizer) Right Side (OD Coil) 24" Below Unit 1 2 0" Above Unit 2 72" (For Outdoor Air Discharge) N ...

  • York SUNLINE 2000 48 - page 16

    036-21564-002-A-0404 16 Unitary Products Group UNIT DIMENSIONS - CONT'D. (BCH - 3, 4 & 5 TON) REAR VIEW SIDE SUPPL Y AND RETURN AIR DUCT OPENINGS 3 DUCT COVERS - Units are shipped with all air duct openings covered. For side duct applications; 1.Remove and discard the supply and return air duct covers. 2.Connect ductwork to duct flanges on ...

  • York SUNLINE 2000 48 - page 17

    036-21564-002-A-0404 Unitary Products Group 17 ROOF CURB DIMENSIONS BCH - 3, 4 & 5 TON COMPRESSOR AND OUTDOOR COIL END OF UNIT DUCT SIZES: Supply Air = 19" x 19" Return Air = 19" x 19" BACK APPROXIMA TE CENTER OF GRA VITY FRONT CENTER OF GRA VITY CORNER CORNER CORNER OPTIONS / ACCESSORIES Electric Heat (Nominal KW) 5 - 7 KW ...

  • York SUNLINE 2000 48 - page 18

    FIELD--INST ALLED ACCESSORIES SINGLE INPUT ELECTRONIC ENTHALPY ECONOMIZER -- Includes a slide--in/plug--in damper assembly with fully modulating spring return motor actuator capable of introducing up to 100% outdoor air , one outdoor air electronic enthalpy sensor and a rainhood with filters. The rainhood is painted to match the basic unit and must ...

  • York SUNLINE 2000 48 - page 19

    036-21564-002-A-0404 Unitary Products Group 19 TYPICAL APPLICATIONS TYPICAL ROOF-TOP INST ALLA TION ROOF JACK INST ALLA TION ROOF CURB INST ALLA TION SLAB ON GROUND INST ALLA TION FIELD-SUPPLIED DISCONNECT SWITCH TO POWER SUPPL Y CONTROL WIRING TO INDOOR THERMOST A T ROOF CURB SUPPL Y AIR DUCT RETURN AIR DUCT CONDENSA TE TRAP ...

  • York SUNLINE 2000 48 - page 20

    GENERAL DESCRIPTION Units shall be factory--assembled, single packaged Heat Pumps, designed for outdoor mounted inst allation. Units shall have minimum SEER ratings of 10.0. They shall have built in field convertible duct connections for down discharge supply/return or horizontal discharge supply/return, and be available with factory installed opti ...

  • York SUNLINE 2000 48 - page 21

    (1) -- Loss--of--charge/Low--pressure switch. (2) -- High--pressure switch. If any of the above safety devices trip, an LED (light emitting diode) indicator shall illuminate. C. Unit shall incorporate “AUTO RESET” compressor over--temperature, over--current protection. D. Unit shall operate with conventional thermostat designs and have a low vo ...

  • York SUNLINE 2000 48 - page 22

    6. THERMOST A TS -- Multiple models available from A.C.O., M.C.O., Electronic or Electrical Mechanical ver - sions. 7. ANTI--RECYCLE TIMER -- Assures 5--minute off--time between compressor cycles. 8. ELECTRIC HEA T -- Slide--in design, provides single point power and ranges from 5 to 30 KW . OTHER F ACTOR Y INST ALLED OPTIONS 1. HIGH PERFORMANCE BE ...

  • York SUNLINE 2000 48 - page 23

    036-21564-002-A-0404 Unitary Products Group 23 ...

  • York SUNLINE 2000 48 - page 24

    Unitary Products Group 5005 Y ork Drive, Norman, Oklahoma 73069 Subject to change without notice. Printed in U.S.A. 035-21564-002-A-0404 Copyright 2004 by Y ork International Corporation. All Rights Reserved. Supersedes: 036-21564-001-A-0204 ...

メーカー York カテゴリー Heat Pump

York SUNLINE 2000 48のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- SUNLINE 2000 48の取扱説明書
- Yorkの製品カード
- パンフレット
- またはYork SUNLINE 2000 48の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、York SUNLINE 2000 48の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、York SUNLINE 2000 48の取り付け説明書、サービスマニュアル、簡易説明書、またはYork SUNLINE 2000 48のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、York SUNLINE 2000 48の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

York SUNLINE 2000 48デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがYork SUNLINE 2000 48を使用するのを助ける技術的文書のことです。説明書は通常、全てのYork SUNLINE 2000 48ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Yorkの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. York SUNLINE 2000 48の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははYork SUNLINE 2000 48の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。York SUNLINE 2000 48に関してこのドキュメントで見つけることができる全てのヒントの目次
3. York SUNLINE 2000 48デバイスの基本機能を使うにあたってのヒント。 York SUNLINE 2000 48のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。York SUNLINE 2000 48に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるYork SUNLINE 2000 48のメーカー/サービスへの連絡先に関する情報。

York SUNLINE 2000 48についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもYork SUNLINE 2000 48の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがYork SUNLINE 2000 48で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)