MHP EWF36Aの取扱説明書

32ページ 2.64 mb
ダウンロード

ページに移動 of 32

Summary
  • MHP EWF36A - page 1

      Homeowner ’ s Installation and Operating Manual  20005167 5/1 1 Rev . 18 5167 EP A36 cover 3/02 ? ...

  • MHP EWF36A - page 2

    2 V er mont Castings EWF36A 20005167  Thank you for purchasing a V ermont Castings, EWF36A replace. An efcient replace carefully engineered to bring you the latest in wood combustion principles and modern foundry technology . Y ou can count on years of comfortable heating and pleasurable re viewing if ...

  • MHP EWF36A - page 3

    3 V er mont Castings EWF36A 20005167      Read all instructions and warnings car ...

  • MHP EWF36A - page 4

    4 V er mont Castings EWF36A 20005167  Range of heat output*................ 1 1,300 - 75,500 Btu/hr Maximum heat output** ..... in excess of 100,000 Btu/hr EP A emissions rating (g/h, catalytic) .......................2.4* Area heated*** ............... Up to 2500 sq. ft. (558 sq. m) Size of wood splits ...... ...

  • MHP EWF36A - page 5

    5 V er mont Castings EWF36A 20005167  Fireplace and chase parts identication. FP554a FP554a BFC Fireplace and chase parts identification circulating model 8/21/00 djt  Insulation methods shown are optional for cold climate, not a requirement for unit operation. T ermination ...

  • MHP EWF36A - page 6

    6 V er mont Castings EWF36A 20005167 D Rise B G H B Offset C E 6 FT . G H A Hearth Floor Chimney Section CHIMNEY FLUE EXIT Elbow FP269 MBUF 5/16/96 rev . 5/25 TCS8A Support Example 1 Example 2 Example 3  ? ...

  • MHP EWF36A - page 7

    7 V er mont Castings EWF36A 20005167  Determine how the chimney will be run, length of run and chimney components required to complete the job. (Fig. 4)  install a chimney below minimum heights. In planning a chimney system, it is important to know: 1. The height of a chimne ...

  • MHP EWF36A - page 8

    8 V er mont Castings EWF36A 20005167  The chimney system is supported by the replace for vertical chimney heights less than 30’ (9m) above the hearth. Chimney supports are required if the vertical height exceeds 30’ (9m). Locate chimney supports at ceiling holes or other structural framing at 3 ...

  • MHP EWF36A - page 9

    9 V er mont Castings EWF36A 20005167  Framing can be constructed before or after the replace is set in place, however , most installers build the frame before setting the replace. Frame replace with 2 x 4 lumber or heavier materi- als. Refer to framing dimensions in Figure 1 for basic replace specications.  ...

  • MHP EWF36A - page 10

    10 V er mont Castings EWF36A 20005167   The size of the hole in ceiling will vary with the angle at which the chimney passes through ceiling. Drive a nail up through ceiling at marked chimney center point. Go to oor ab ...

  • MHP EWF36A - page 11

    1 1 V er mont Castings EWF36A 20005167   An outside air kit may be installed on the EWF36A. If desired, or if local codes mandate the use of an air kit, then two (2) AK-MST s are required to complete the installation (from air kit to the outdoors). If the outside ai ...

  • MHP EWF36A - page 12

    12 V er mont Castings EWF36A 20005167  Start by attaching the rst chimney section to the collar on top of the replace.  Install the pipe as pictured in Figure 16. When you get a good lock, you will hear the pipe clearly snap together . Once sections a ...

  • MHP EWF36A - page 13

    13 V er mont Castings EWF36A 20005167   A restop spacer is used to keep pipe spaced properly and required for safety . Nail the restop spacer (at each corner) to the framing members of the ceili ...

  • MHP EWF36A - page 14

    14 V er mont Castings EWF36A 20005167  Run pipe to rooine. Since chimney system must be vented to the out-of-doors, you  use an approved MHSC termination. If a chase is used, refer to the installation manual pro- vided with the termination cap.  ...

  • MHP EWF36A - page 15

    15 V er mont Castings EWF36A 20005167   Finish the wall with material of your choice.   ? ...

  • MHP EWF36A - page 16

    16 V er mont Castings EWF36A 20005167  1. Manville - CERAFORM 126, K=.27, 1/2 inches thick 2. EH2416, K = .458, 1 inch thick required.  A hearth extension is required to protect a combusti ...

  • MHP EWF36A - page 17

    17 V er mont Castings EWF36A 20005167 FP1201  Combustible side wall protection and hearth extension dimensions. Minimum W all Clearances WITH Noncombustible Surround Facing WITHOUT Noncombustible Surround Facing Minimum Hearth Extension Dimensions (for On-Site Construction) G H G J Seal cracks between the fireplace and hearth e ...

  • MHP EWF36A - page 18

    18 V er mont Castings EWF36A 20005167   The fallaway handles are used to open and close the front doors. Remove after each use so they will not get hot. Keep in convenient location for each use. (Fig. 27) Assemble the primary air control and damper handles by passing the 3 ³⁄? ...

  • MHP EWF36A - page 19

    19 V er mont Castings EWF36A 20005167 KT108b BFC Correct door position 8/23/00 djt KT108b  Correct door position during operation.  Optional Spark Screen   Heated air from the replace is forced into the room by an internal fan. The control for the fan is in the r ...

  • MHP EWF36A - page 20

    20 V er mont Castings EWF36A 20005167   ? ...

  • MHP EWF36A - page 21

    21 V er mont Castings EWF36A 20005167 Different results may be experienced even in the same installation if you switch from burning good, dry wood to wood that is partially rotted or inadequately seasoned. T o compensate for these factors in cold climates, it may be necessary to operate the EWF36A with the air con- trol set to a higher level more o ...

  • MHP EWF36A - page 22

    22 V er mont Castings EWF36A 20005167     An occa sio nal dus ting wit h a dry ra g wi ...

  • MHP EWF36A - page 23

    23 V er mont Castings EWF36A 20005167  The bes t w ay t o e valu ate the per for manc e of yo ur EWF 36A’ s c ombu sto r is to obs erve th e am ount of smo ke lea ving th e ch imn ey - bot h w hen the com bust or has “li ghte d-o ff” and w ...

  • MHP EWF36A - page 24

    24 V er mont Castings EWF36A 20005167  Gasket Size... ...And The Parts It Seals 3/4” The door to the front 3/4” Door to the hearth brick support 3/16” The glass seal to the door 1/2” Cat holder to top plate 1/2” Braided Damper to top plate Should you ...

  • MHP EWF36A - page 25

    25 V er mont Castings EWF36A 20005167 The prefabricated chimney used with your replace should be cleaned from above using an 8” round brush and the appropriate number of extension rods for com- plete access. The chimney cap rst must be removed following the procedure recommended by the manufacturer . After thoroughly cleaning the chimney , ...

  • MHP EWF36A - page 26

    26 V er mont Castings EWF36A 20005167  Component Description Model Number Chimney Support Used to support chimney for each of TCS8A 30’ vertical height and 6’ of angled chimney run (8” ue) Firestop Required at each oor level and attic on FS2A (8” straight ue) multi-story install ...

  • MHP EWF36A - page 27

    27 V er mont Castings EWF36A 20005167 1 3 7 5 6 1 1 46 40 13 13 20 22 15 86 15 10 37 36 47 47 45 41 44 16 16 17 39 52 27 28 29 30 31 19 33 34 35 9 54 32 42 43 2 2 4 56 55 52 48 51 50 49 73 74 EWF36CLK 75 75 65 EWF36CLK EWF36CLK 76 76 EWF36CLK 79 79 80 80 82 83 84 85 81 82 83 84 85 EWF36S 24 25 26 24 25 26 18 24 25 26 87 38 62 63 64 EWF36CFTK 24 25 ...

  • MHP EWF36A - page 28

    28 V er mont Castings EWF36A 20005167 22. Glass Right Door - EP A Front 20005152 23. Right, Door Handle Assy . V ert. Nickel 20006286 24. Damper Steel Handle w/Screw 5004265 25. Handle, Ceramic Blk 2.78 Lg 20006381 26. Ov Hd Sl 1/4-20 x 3/375 Lg 1201294 27. Linkage Assy . 20005307 28. Pawl, T op 20005154 29. Pawl, Bottom 20005155 30. Link, EP A FP ...

  • MHP EWF36A - page 29

    29 V er mont Castings EWF36A 20005167     The FK26 fan helps distribute heated air from within the rebox out into the room. The fan is controlled by a snapstat that turns power on and off as the rebox tem- perature rises above and falls be ...

  • MHP EWF36A - page 30

    30 V er mont Castings EWF36A 20005167 ...

  • MHP EWF36A - page 31

    31 V er mont Castings EWF36A 20005167        ? ...

  • MHP EWF36A - page 32

     149 Cleveland Drive • Paris, Kentucky 40361 www .mhsc.com ...

メーカー MHP カテゴリー Indoor Fireplace

MHP EWF36Aのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- EWF36Aの取扱説明書
- MHPの製品カード
- パンフレット
- またはMHP EWF36Aの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、MHP EWF36Aの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、MHP EWF36Aの取り付け説明書、サービスマニュアル、簡易説明書、またはMHP EWF36Aのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、MHP EWF36Aの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

MHP EWF36Aデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがMHP EWF36Aを使用するのを助ける技術的文書のことです。説明書は通常、全てのMHP EWF36Aユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

MHPの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. MHP EWF36Aの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははMHP EWF36Aの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。MHP EWF36Aに関してこのドキュメントで見つけることができる全てのヒントの目次
3. MHP EWF36Aデバイスの基本機能を使うにあたってのヒント。 MHP EWF36Aのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。MHP EWF36Aに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるMHP EWF36Aのメーカー/サービスへの連絡先に関する情報。

MHP EWF36Aについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもMHP EWF36Aの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがMHP EWF36Aで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)