    323617A-01 May 2003 © 2003 National I nstruments Corp. Al l rights res erved. FieldPoint™, Nati onal Instruments™, NI™, and ni.com™ are trademarks of National Instruments Corporation. Product and company names ment ioned herein are trademark s or trade names of their respecti ve companies. For patents covering National Inst ruments product ...

  • National Instruments CFP-RLY-421 - page 2

    cFP-RLY-421 2 ni.com Before you conf igure a FieldPoint system that uses a cFP-RL Y -421 module, calculate the total power consumption of the I/O modules on the FieldPoint bank. Y ou ca n find the po wer requirement specification in the operating inst ructions for ea ch I/O module . The maximum power the netw ork module can supply is specified in t ...

  • National Instruments CFP-RLY-421 - page 3

    © National Instruments Corp. 3 cFP-RLY-421 Figure 1. Installing the cFP-RL Y -421 Wiring the cFP-RL Y -421 The cFP-CB- x connector block has conne ctions for each of the eight cFP-RL Y -421 relay channels and for an external supply to power f ield devices. If you are using the cFP-RL Y - 421 in a hazardous voltage application, you mu st use the cF ...

  • National Instruments CFP-RLY-421 - page 4

    cFP-RLY-421 4 ni.com T able 1 li sts the terminal assign ments for the signals of each channel. All of the COM terminals are conne cted internally and all of the V SUP terminals are connected inte rnally . NI does not recommend using them with the cFP-RL Y -421. Caution Cascading power between two modules defeats isolation between those modules. Ca ...

  • National Instruments CFP-RLY-421 - page 5

    © National Instruments Corp. 5 cFP-RLY-421 Connecting Loads to the cFP-RL Y -421 W ire an external po wer supply to the load and IC terminal of the individu al channel as shown in Figure 2. This method of wiring keeps the electrical connections of the cFP-RL Y -421 within safe current limits. Figure 2. Connecting a Load The cFP-RL Y -421 has eight ...

  • National Instruments CFP-RLY-421 - page 6

    cFP-RLY-421 6 ni.com In addition, the cFP-RL Y -421 has internal protection MO Vs to pre vent excessiv ely high voltag e from being applied across the contacts. The MO Vs are located between the NO and IC contacts of each relay . Howe ver , National Instruments still recommends the use of a protection circuit across an inductive load. The flyback p ...

  • National Instruments CFP-RLY-421 - page 7

    © National Instruments Corp. 7 cFP-RLY-421 Diode Circuit CR Circuits Varistor Circuit Diagram Notes Use in DC applications only . Compared to RC type, circuit delays release time (2 to 5 times values stated in catalog). For lar ger voltages, use diode with rev erse breakdo wn 10 times circu it voltage an d forward load circuit. For smaller v oltag ...

  • National Instruments CFP-RLY-421 - page 8

    cFP-RLY-421 8 ni.com In-Rush Current The type of l oad and its in-rush current charac teristics, together with switching frequency , can ca use contact welding. For loads with in-rush current, measure the steady state current and in-rush current to determine the proper rela y . Some typical types of loads and the in-rush current they create are sum ...

  • National Instruments CFP-RLY-421 - page 9

    © National Instruments Corp. 9 cFP-RLY-421 Upgrading the FieldPoint Firmware Y ou may need to upgrade the FieldPoint f irmware when you add ne w I/O modules to the FieldPoi nt system. For information on determining which fi rmware you need and ho w to upgrade the firmw are, go to ni.com/info and enter fpmatrix . Isolation and Sa fety Guidelines Ca ...

  • National Instruments CFP-RLY-421 - page 10

    cFP-RLY-421 10 ni.com •D o not share the exter nal supply voltages (the V and C terminals) with other de vices (including othe r FieldPoint de vices), unless those devices ar e isolated from human contact. • Y ou must connect the protecti ve ea rth (PE) ground terminal on the cFP-BP- x backplane to the syst em safety ground. The backplane PE gr ...

  • National Instruments CFP-RLY-421 - page 11

    © National Instruments Corp. 11 cFP-RLY-421 Specifications The follo wing specifications ar e typical for a range of – 40 to 60 °C unless otherwise noted. Relay Characteristics Number of channels ..................... ..... 8 Relay type ......... ...................... .......... 1 SPST , nonlatching Maximum switching ca pacity (resisti ve load ...

  • National Instruments CFP-RLY-421 - page 12

    cFP-RLY-421 12 ni.com Physical Indicators ..... .............. ........... ........... . Green POWER and READY indicators, 8 green output state indicators W eight cFP-RL Y -421 .................... .......... 130 g (4.5 oz) Power Requirements Power from network modul e ............ 1,700 mW Isolation Voltage Maximum isolation v oltage ............. ...

  • National Instruments CFP-RLY-421 - page 13

    © National Instruments Corp. 13 cFP-RLY-421 Safety This product is designed to meet the requirements of the following standards of safety for electric al equipment for measurement, control, and laboratory use: • IEC 61010-1, EN 61010-1 • UL 3121-1, UL 61010C-1 • CAN/CSA C22.2 No. 1010.1 For UL, hazardous location, and othe r safety certifica ...

  • National Instruments CFP-RLY-421 - page 14

    cFP-RLY-421 14 ni.com Where to Go for Support For more information about settin g up the FieldPoint system, refer to these National Instruments documents: • FieldPoint network module user manual • Other FieldPo int I/O m odule operating instructions • FieldPoint connector bl ock operating instructions Go to ni.com/support for the most current ...

メーカー National Instruments カテゴリー Electronic Accessory

National Instruments CFP-RLY-421のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- CFP-RLY-421の取扱説明書
- National Instrumentsの製品カード
- パンフレット
- またはNational Instruments CFP-RLY-421の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、National Instruments CFP-RLY-421の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、National Instruments CFP-RLY-421の取り付け説明書、サービスマニュアル、簡易説明書、またはNational Instruments CFP-RLY-421のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、National Instruments CFP-RLY-421の製品を使用するにあたって最も人気のある説明書を閲覧できます。

National Instruments CFP-RLY-421デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがNational Instruments CFP-RLY-421を使用するのを助ける技術的文書のことです。説明書は通常、全てのNational Instruments CFP-RLY-421ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

National Instrumentsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. National Instruments CFP-RLY-421の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははNational Instruments CFP-RLY-421の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。National Instruments CFP-RLY-421に関してこのドキュメントで見つけることができる全てのヒントの目次
3. National Instruments CFP-RLY-421デバイスの基本機能を使うにあたってのヒント。 National Instruments CFP-RLY-421のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。National Instruments CFP-RLY-421に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるNational Instruments CFP-RLY-421のメーカー/サービスへの連絡先に関する情報。

National Instruments CFP-RLY-421についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもNational Instruments CFP-RLY-421の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがNational Instruments CFP-RLY-421で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)