    Operating and Installation Instr uctions V entilation System D A 402 T o pr event accidents and machine damage, read these instructions before installation or use. UV M.-Nr . 06 473 980 ...

  • Miele DA 402 - page 2

    IMPORT ANT SAFETY INSTR UCTIONS Functional description Guide to the appliance Operation T urning on the fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Selecting the power level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Delayed Shut Down . . . ...

  • Miele DA 402 - page 3

    Read these Operating Instructions carefully bef ore installing or using the V entilation System. This appliance is intended for residential use only . Use the appliance only for its intended purpose. The manufacturer cannot be held responsible for damages caused by improper use of the hood. This appliance complies with current safety requir ements. ...

  • Miele DA 402 - page 4

    This equipment is not designed for maritime use or for use in mobile installations such as recr eational vehicles or aircraft. However , under certain conditions it may be possible for installation in these applications. Please contact the nearest Miele dealer or the T echnical Service Department with specific requir ements. Before servicing or cle ...

  • Miele DA 402 - page 5

    , W ARNING - T O REDUCE THE RISK OF A COOKT OP GREASE FIRE: Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers may ignite. Heat oils slowly on low or medium settings. Always turn the hood on when cooking at high heat or when cooking flaming foods. Clean ventilation fans frequently . Grease should no ...

  • Miele DA 402 - page 6

    Installation , W ARNING T o reduce the risk of fire only use metal ductwork. When installing the hood, follow the recommended minimum safety distances between a Miele cooktop and the hood: – 22" (55 cm) above electric cooktops, – 26" (65 cm) above gas cooktops, – 26" (65 cm) above an open grill. If local building codes requir e ...

  • Miele DA 402 - page 7

    The ventilation hood works by air extraction. The air is drawn in and cleaned by the grease filters and directed outside. The hood comes equipped with a non-return flap . This flap automatically closes when the hood is turned off so that no exchange of outside air and room air can occur . When the hood is turned on, the air pressure of the exhaust ...

  • Miele DA 402 - page 8

    Guide to the appliance 8 a b c f d e k g h i j dai1664 n s – + 51 5 m n s – + 51 5 m | l ...

  • Miele DA 402 - page 9

    a Chimney e xtension b Chimney c Canopy d Control panel e Grease filter f Overhead lighting g Light button This button turns the light on and off and also dims the light. The lighting can be used independently from the fan. h On/Off button i Fan po wer selection Four fan speed selection j Delay ed shut down This button activates the Delayed Shut Do ...

  • Miele DA 402 - page 10

    T urning on the fan ^ Press the On/Of f button. Selecting the power le vel ^ Use the " – / + " controls to select the desired power level. & = increases the fan speed $ = decreases the fan speed Level "1" to "3" (green indicators) ar e usually sufficient for normal cooking. Intensive setting Level "4" ( ...

  • Miele DA 402 - page 11

    If the power level indicators flash the automatic switch back is not activated. ^ T o activate the automatic switch press the " + " button. The power level indicators light. ^ T o deactivate the automatic switch press the " – " button. ^ T o save the setting press the Delay Shut down button. If the procedur e is not stored wit ...

  • Miele DA 402 - page 12

    Delay ed Shut Down If odors or smoke remain in the kitchen after cooking has been completed, the Delayed Shut Down feature can be selected to allow the hood to continue running for either 5 or 15 minutes. ^ Press the Delayed Shut Down button while the fan is still running. Press once = 5 minute delay (left indicator lights) Press twice = 15 minute ...

  • Miele DA 402 - page 13

    T urning the lighting on/off The overhead lighting can be turned on and off independently fr om the fan. ^ Press the light button briefl y to turn on the lighting. The light button indicator illuminates. ^ Press the light button briefl y again to turn off the lighting. The light button indicator will go out. Dimming the lighting The brightness of t ...

  • Miele DA 402 - page 14

    Filter timers A timer monitors the hours of fan operation. The indicator for the grease filter will light after 30 hours of operation. The grease filters must then be cleaned. After the grease filters have been cleaned and put in place, the grease filter timer must be reset. ^ T o do this, press the gr ease filter button for about 3 seconds. The in ...

  • Miele DA 402 - page 15

    Reprogramming the timer s The grease filter timer is pr eset to 30 hours. This time can be lengthened or shortened to 20, 30, 40, or 50 hours. – A time of 20 hours should be programmed in kitchens with frequent pan or deep frying. – A time of 20 hours should also be programmed if the kitchen is only used occasionally to prevent gr ease which ha ...

  • Miele DA 402 - page 16

    Before cleaning or servicing the hood, disconnect it from the power supply by either removing the fuse, unplugging it from the outlet, or manually "tripping" the circuit breaker . Cleaning the casing W arning: Never use abrasive cleaners, scouring pads, steel wool or caustic (oven) cleaners on the hood. They will damage the surface. ^ All ...

  • Miele DA 402 - page 17

    Grease filters The reusable metal gr ease filters remove solid particles from the vented kitchen air (grease, dust, etc). The grease filters should be cleaned every 3 - 4 weeks or when the grease filter indicator lights. A dirty filter is a fire hazard. ^ T o remove the gr ease filters pull the locking clips, 1 , forward. Lower the filter 45°, 2 , ...

  • Miele DA 402 - page 18

    Changing the light bulb Before changing the light bulbs, disconnect the hood from the power supply by either removing the fuse, unplugging it, or manually "tripping" the circuit br eaker . When in use halogen bulbs become extremely hot, and they can burn your hands. Do not attempt to change the bulbs until they have had sufficient time to ...

  • Miele DA 402 - page 19

    In the event of a fault which you cannot correct yourself please contact the Miele T echnical Service Department : U 1-800-999-1360 techserv@mieleusa.com V 1-800-565-6435 service@miele.ca When contacting the T echnical Service Department, please quote the model and serial number of your appliance. These are shown on the data plate which is visible ...

  • Miele DA 402 - page 20

    20 ...

  • Miele DA 402 - page 21

    Installation Instr uctions ...

  • Miele DA 402 - page 22

    22 ...

  • Miele DA 402 - page 23

    Disposal of packing material The cardboar d box and packing materials protect the appliance during shipping. They have been designed to be biodegradable and recyclable. Please recycle. T o prevent suf focation of children, ensure that any plastic wrappings, bags, etc. are disposed of safely and kept out of their reach. Disposal of an old appliance ...

  • Miele DA 402 - page 24

    Installation accessories 24 ...

  • Miele DA 402 - page 25

    a 3 protective shields to pr event scratches to the chimney during installation. b 2 hose clips for securing the ducting. c 1 reducing collar for use with 5" (125 mm) exhaust ducting. d T elescopic retaining plate secures the chimney extension Caution: During the installation process, please be car eful of sharp edges. 8 large headed screws 5 ...

  • Miele DA 402 - page 26

    The majority of the weight of the installed ventilation system will be supported by the lower retaining plate. It must be firmly attached to the stud framing behind the drywall. If studs are not available in the requir ed locations, a plywood backing (min. 1 / 2 " (13 mm) thick) spanning at least two studs must be installed. Failure to adequat ...

  • Miele DA 402 - page 27

    All electrical work should be perfor med by a qualified electrician in strict accordance with national and local safety regulations. Installation, repairs and other work by unqualified persons could be dangerous. The manufactur er cannot be held responsible for unauthorized work. Ensure that power to the appliance is off while installation or r epa ...

  • Miele DA 402 - page 28

    1) and 2) Installation area W all/ceiling area r espectively for vent hole and outlet installation. V ent hole 5 7 / 8 " (150 mm) with r educing collar 5" (125 mm). Appliance dimensions 28 ...

  • Miele DA 402 - page 29

    Do not install this exhaust hood over cooktops burning solid fuel. When installing the hood, make sure that the following minimum distance ( S ) between the top of a Miele cooking surface and the bottom of the hood is: - 22" (55 cm) above electric cooktops - 26" (65 cm) above gas cooktops - 26" (65 cm) above an open grill For non-Mie ...

  • Miele DA 402 - page 30

    Installation instructions See the enclosed installation instruction sheet. Please read the "Important Safety Instructions" and Installation instructions before installing this hood. Protective film The casing is covered with a pr otective film to prevent scratching during transport. Peel off the film befor e installing the casing parts. D ...

  • Miele DA 402 - page 31

    , W ARNING Danger of toxic fumes. Gas cooking appliances release carbon mono xide that can be harmful or fatal if inhaled. The exhaust gases extracted b y the hood should be vented outside of the building onl y . Do not terminate the exhaust ducts in attics, garages, crawlspaces, etc. T o reduce the risk of fire, onl y use metal ductwork. Please re ...

  • Miele DA 402 - page 32

    If the exhaust is ducted into an inactive flue, the air must be expelled parallel to the flow direction of the flue. Never connect an exhaust hood to an active chimney , dryer vent, vent flue, or room venting ductwork. Seek professional advice befor e connecting an exhaust hood vent to an existing, inactive chimney or vent flue. Important! If the d ...

  • Miele DA 402 - page 33

    33 ...

  • Miele DA 402 - page 34

    34 ...

  • Miele DA 402 - page 35

    35 ...

  • Miele DA 402 - page 36

    M.-Nr . 06 473 980 / 00 - Alteration rights reserved / 0805 ...

メーカー Miele カテゴリー Ventilation Hood

Miele DA 402のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- DA 402の取扱説明書
- Mieleの製品カード
- パンフレット
- またはMiele DA 402の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Miele DA 402の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Miele DA 402の取り付け説明書、サービスマニュアル、簡易説明書、またはMiele DA 402のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Miele DA 402の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Miele DA 402デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがMiele DA 402を使用するのを助ける技術的文書のことです。説明書は通常、全てのMiele DA 402ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Mieleの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Miele DA 402の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははMiele DA 402の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Miele DA 402に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Miele DA 402デバイスの基本機能を使うにあたってのヒント。 Miele DA 402のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Miele DA 402に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるMiele DA 402のメーカー/サービスへの連絡先に関する情報。

Miele DA 402についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもMiele DA 402の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがMiele DA 402で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)