  • Graco Ultra Max 309273 - page 1

    Ultra Max t Electric Airless Sprayers Operating Instructions The intent of these instructions is to provide the new painter with a quick and easy reference to become familiar with airless sprayers. This does not replace the Instruction Manual supplied with this sprayer . Read and understand the instructions and warnings in that manual. Important No ...

  • Graco Ultra Max 309273 - page 2

    2 309273 PRESSURE RELIEF – Do this when cleaning, repairing or shuting down sprayer WASTE RESÍDUOS À JETER DESECHO 1. T urn pressure to lowest setting. T urn power OFF . Unplug sprayer . 2. T rigger gun to relieve pressure. 3. Put drain tube in pail . T urn prime valve down. W ARNING Fire and explosion hazard: Solv ent and pa i nt f um es c an ...

  • Graco Ultra Max 309273 - page 3

    3 309273 Power Switch Pressure Control Component Identification Suction T ube Filter Prime V alve Prime/drain position Paint position Spray Gun T rigger Safety Put trigger safety ON when not spraying. T ake trigger safety OFF before triggering gun. Digital Display (Not available on all models) 15/20A Switch AutoClean V alve (Not available on all mo ...

  • Graco Ultra Max 309273 - page 4

    4 309273 1. Connect Graco airless hose to sprayer . T ighten securely . 2. Connect other end of hose to gun. Setup 3. T ighten securely . 4. Remove tip guard. ...

  • Graco Ultra Max 309273 - page 5

    5 309273 5. Check inlet strainer for clogs and debris. 6. Fill throat packing nut with TSL to prevent premature packing wear . Do this each time you spray . Approximate Fill Level ...

  • Graco Ultra Max 309273 - page 6

    6 309273 P AINT FLUSH 7. T urn power OFF . 8. Plug power supply cord into a properly grounded electrical outlet. 9. T urn prime valve down. 10. Place suction tube and drain tube in grounded metal pail partially filled with flushing fluid. Attach ground wire to pail and to true earth ground. Do 1 . – 5 . of Startup to flush out storage oil shipped ...

  • Graco Ultra Max 309273 - page 7

    7 309273 FLUSH Note: Inspect fittings for leaks. Do not stop leaks with your hand or a rag! If leaks occur , do Pressure Relief . T ighten leaky fittings. Repeat Startup, 1. – 5 . If no leaks, continue to trigger gun until system is thoroughly flushed. Proceed to 6. Startup 15 SEC 1. T urn prime valve down. T urn pressure control to lowest pressu ...

  • Graco Ultra Max 309273 - page 8

    8 309273 FLUSH P AINT General Surfaces T ip Recommendations Chart Wood Interi or C ab- inets , Paneling Interior Walls or Ceilings Dry wall, Plaster Ov er Hang Su rfaces Materi als Filter Mesh 6–8 8–10 10–12 12–14 Orific e Size (in. ) Fan Widt h ( in.) at 12 in . Masonr y Bl ock, Stu cco, Co ncre te Wood Ex terior Shingle, Siding, Shiplap O ...

  • Graco Ultra Max 309273 - page 9

    9 309273 SwitchTip and Guard Assembly 1. Insert SwitchT ip. Insert seat and OneSeal. 2. Screw assembly onto gun. Hand tighten. SwitchT ip OneSeal seat Press SMARTCONTROL button to cycle through PRESSURE – GAL/L TR – TIMER displays D PRESSURE : Fluid pressure at the sprayer D GAL/L TR : Accumulated total of gallons/liters sprayed D TIMER : Durat ...

  • Graco Ultra Max 309273 - page 10

    10 309273 Spray T est Pattern heavy edges Clearing Tip Clogs 1. T rigger gun and spray test pattern. Slowly adjust pressure to eliminate heavy edges. Use smaller tip size if pressure adjustment can not eliminate heavy edges. 2. Hold gun perpendicular , 10–12 in. (25–30 cm) from surface. Spray back and forth. Use strokes overlapped by 50%. Start ...

  • Graco Ultra Max 309273 - page 11

    11 309273 Cleanup P AINT 1. T urn power OFF . 2. T urn pressure to lowest setting. T rigger gun to relieve pressure. 3. T urn prime valve down. 4. Remove filter assembly and assemble gun without filter . Perform AutoClean procedure (Manual 309278) or follow conventional flushing/cleaning procedure that follows: ti2874a Contractor Contractor II ...

  • Graco Ultra Max 309273 - page 12

    12 309273 5. Remove guard and SwitchT ip. 6. Clean filter , guard and SwitchT ip in flushing fluid. P AINT FLUSH 7. Remove siphon tube set from paint and place in flushing fluid. Use water for water base paint and mineral spirits for oil base paint. 8. If sprayer has a filter , unscrew bowl, remove filter . Assemble without filter . Clean filter . ...

  • Graco Ultra Max 309273 - page 13

    13 309273 P AINT FLUSH 9. T urn power ON. 10. T urn prime valve hori- zontal. 1 1. Hold gun against paint pail. T ake trigger safety OFF . T rigger gun until flushing fluid appears. 12. Move gun to flushing pail, hold gun against pail, trigger gun to thoroughly flush system. Release trigger and put trigger safety ON. 13. T urn prime valve down and ...

  • Graco Ultra Max 309273 - page 14

    14 309273 P AINT FLUSH FLUSH 14. Raise siphon tube above flushing fluid and run sprayer for 15 to 30 seconds to drain fluid. T urn power OFF . 15. Make sure plastic center tube is tightened securely . Install filter bowl and filter . Hand tighten filter bowl. Install filter assembly into gun. Hand tighten gun handle. 16. Wipe sprayer , hose and gun ...

  • Graco Ultra Max 309273 - page 15

    15 309273 T rouble Shooting TYPE OF PROBLEM WHA T TO CHECK If check is OK, go to next check WHA T TO D O When check is not OK refer to this column D Sprayer does not respond 1. Check if error code is displayed, page 9. 1. Refer to your repair manual. D Sprayer will not prime or takes too long to prime 1 . Air in paint pump 1. Open prime valve to pu ...

  • Graco Ultra Max 309273 - page 16

    16 309273 Daily: Inspect, clean and replace as needed D Manifold filter , gun filter and inlet stainer D W et cup for leakage, tighten if needed D TSL level D Gun trigger safety D T ip wear , replace if necessary D Electric cord and plug W eekly: D Check tightness of wet cup. D Inspect all high pressure paint hoses. Annually: D Schedule maintenance ...

メーカー Graco カテゴリー Paint Sprayer

Graco Ultra Max 309273のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- Ultra Max 309273の取扱説明書
- Gracoの製品カード
- パンフレット
- またはGraco Ultra Max 309273の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Graco Ultra Max 309273の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Graco Ultra Max 309273の取り付け説明書、サービスマニュアル、簡易説明書、またはGraco Ultra Max 309273のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Graco Ultra Max 309273の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Graco Ultra Max 309273デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがGraco Ultra Max 309273を使用するのを助ける技術的文書のことです。説明書は通常、全てのGraco Ultra Max 309273ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Gracoの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Graco Ultra Max 309273の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははGraco Ultra Max 309273の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Graco Ultra Max 309273に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Graco Ultra Max 309273デバイスの基本機能を使うにあたってのヒント。 Graco Ultra Max 309273のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Graco Ultra Max 309273に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるGraco Ultra Max 309273のメーカー/サービスへの連絡先に関する情報。

Graco Ultra Max 309273についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもGraco Ultra Max 309273の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがGraco Ultra Max 309273で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)