  • Fujitsu XG1200 - page 2

    Preface 1 Y ou have purchased the XG1200, a compact, 12 port 10 Gigabit Ethernet layer 2 switch that achieves unsurpassed standards of high throughput and low-latency performance. This manual explains the procedu res required to install your XG1200 and should be read and understood before you start using your XG1200. First edition (September 2 005) ...

  • Fujitsu XG1200 - page 3

    2 Fo r Safe Use of the XG1200 W arnings are included th roughout this manual in order to pre vent injury to the user and/or material damage. There are two levels of wa rnings, both of which are compo sed of a symbol and a message de scribing the issue. For Safe Use of the XG1200 This manual con tains import ant information to ensure the sa fe use o ...

  • Fujitsu XG1200 - page 4

    For Safe Use of the XG1200 3 This symbol indicates the po ssibility of serious or fata l injury if the XG1200 is not used properly. For your safety and that of others , please follow these guidelines. Category Warning Danger of electric shock or fire Never attempt to disassemble, dismantle, upgrade, or recycle the XG1200 by yourself. Do not place o ...

  • Fujitsu XG1200 - page 5

    4 Fo r Safe Use of the XG1200 This symbol indicates the possibility of minor or mod erate personal injury, as well as damage to the XG1200 and/or to other users and their property, if th e XG1200 is not used pro perly. Category Caution Danger of device damage Do not place the XG1200 on it s side or stack up multip le XG1200s. Doing so may damage th ...

  • Fujitsu XG1200 - page 6

    For Safe Use of the XG1200 5 Never attempt to dismantle or modify the XG1200 yourself. This is extremely dangerous since the XG1200 includes both high volt age and high temp erature components. If maintenance is required, contact the vendor's service department. The following warning label may be found on the rear of XG1200. Do not attempt to ...

  • Fujitsu XG1200 - page 7

    6 Fo r Safe Use of the XG1200 FCC Class A CE Marking CAN/CSA C22.2 No. 60950, UL60950 an d EN60950 Under certain conditions, twisted pair cables can become charged with static electricity . Connecting a statically charged twiste d pair cable to a device can cause the device or its LAN port to operate fa lsely or to become da maged. Use a static rem ...

  • Fujitsu XG1200 - page 8

    About This Manual 7 This manual is written for an administrator who has responsib ility for network system configu- ration, maintenance, and management. Understanding of the following knowledge is expected. • Basic knowledge of networks, intrane ts and the internet. • Basic knowledge of system management. • Basic knowledge of system security. ...

  • Fujitsu XG1200 - page 9

    8 About This Manual This manual uses the following symbols. Company names and products names referred in this manual are registered trademarks or trademarks of respective companies. The trademark ™ and ® have been omitted from this manual. The latest product information includ ing technical information, update information, are av ail- able from ...

  • Fujitsu XG1200 - page 10

    3 Content s 9 1 2 A Contents Preface ............... ................... ................... .................... ...................... .......... 1 For Safe Use of the XG1200 .............. ....................... ................... ................ 2 Warning notations .............. ................. ................. ................. ........ ...

  • Fujitsu XG1200 - page 11

    10 Contents Appendix ............ ............................ .......................................... ........... 37 Appendix-A Specifications .... ....................... ................... ....................... .............. 38 A.1 Product Specifications ..... ............................ ....................................... ........ 3 ...

  • Fujitsu XG1200 - page 12

    Before Use This chapter lists the items that should be in the XG1200 packag e, describes the names and functions of the various compo nents of the XG1200. 1-1 Parts List .................................................................................................. 12 1-2 XG1200 Component s ....................................................... ...

  • Fujitsu XG1200 - page 13

    12 Before Use 1-1 Part s List Before proceeding, check that all of the following parts were included in your XG1200 package. Contact the vendor's service department if any part s are missing and/o r the manual has any miss- ing or wrongly coll ated pages. Keep the hardware guide (this manual) and the CD-ROM in a safe place. XG1200 CD-ROM Hardw ...

  • Fujitsu XG1200 - page 14

    Part s List 13 1 • XG1200 The XG1200 itsel f (from zero to eight Xenpak module s may be installed). • Power Cord A 3-pin cabl e to connect the XG1200 to a power supply. • Serial Cross Cable A cable t o connect the XG1200 t o a PC when the s ettings need to be ad justed. • Rack Mounting Bracket L A bracket f or mounti ng the XG1200 in a rack ...

  • Fujitsu XG1200 - page 15

    14 Before Use The following explains the names and functi ons of the components at the front of the XG1200. • Power LED (Green) Lights when the XG1200 is receiving power. • Alarm LED (Orange) Lights when there is a problem with the XG1200. • Status LED (Green) Lights when t he XG1200 is in an operable state. • Serial Port Used when perf orm ...

  • Fujitsu XG1200 - page 16

    XG1200 Comp onents 15 1 The following e xplains the names and functions of the components at t he rear of the XG1200. • Power Switch Used to turn t he XG1200 on/of f. • Power Supply Uni t Supplies powe r to the XG1200 (inc ludes an exhaust fan) . - Power Supply LED (Green) Lights when the XG1200 is on. - Power Fail LED (Orange) Lights when ther ...

  • Fujitsu XG1200 - page 17

    16 Before Use There are th ree main indicato r LEDs on the fr ont of the XG1200: Power LED, Alarm LED, and Status LED. The following explains th e LED display under various conditions. *1: If the XG1200 is operating normally. If a problem occurs, the front panel LEDs an d the LEDs on the individual parts can be used to identify the trouble: *2: Onl ...

  • Fujitsu XG1200 - page 18

    Labels 17 1 Obey the following warning: 1-3 Labels A warning sticker , product nameplate, product ID label, and MAC la bel are to be found in various places on the XG1200. Product Nameplate Rear View of XG1200 Right View of XG1200 T op View of XG1200 Product ID Label MAC Label Warning Sticker FAN Warning sticker ...

  • Fujitsu XG1200 - page 19

    18 Before Use This indicates the model, part number, serial numb er, etc. This indicates the model, serial number, etc. Product nameplate MODEL. PART NO. PA SER NO. P 1 50/60Hz **** Kg 100-240V *** **** A/INPUT 0 1 2 3 4 5 6 7 8 9 a FUJITSU company MADE IN JAPAN 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 ****** ***** Model Part Number Rev. Label PFU L ...

  • Fujitsu XG1200 - page 20

    Labels 19 1 This indicates the MAC address: MAC addresses are allotted relative to the address on the MAC la bel: MAC Label Address on the MAC label Location xx:xx:xx:xx:x x:xx Mng-LAN xx:xx:xx:xx:x x:xx+1 XG1200 xx:xx:xx:xx:x x:xx+2 Port 1 xx:xx:xx:xx:x x:xx+3 Port 2 xx:xx:xx:xx:x x:xx+4 Port 3 xx:xx:xx:xx:x x:xx+5 Port 4 xx:xx:xx:xx:x x:xx+6 Port ...

  • Fujitsu XG1200 - page 21

    20 Before Use ...

  • Fujitsu XG1200 - page 22

    Installation and Operation This chapter explains how the user should proceed from installation to opera tion of the XG1200. 2-1 Installation Overview ............................................................................... 22 2-2 Installation Procedure .............................................................................. 23 2-2-1 In ...

  • Fujitsu XG1200 - page 23

    22 Instal lation and Opera tion Install the XG1200 and the proceed with normal operation as follows: 2-1 Inst allation Overview This section reviews the flow of work as the user proceeds from in stallation to operation of the XG1200. Check that the everything is secure 4 Turn the power on 5 "For Safe Use of the XG1200", "2-2 Installa ...

  • Fujitsu XG1200 - page 24

    Inst allation Procedure 23 2 Before installing the XG1200, read " For Safe U se of the XG1200" (page 2) a nd comply with the installa tion requiremen ts described belo w. When installin g the XG1200, a certai n amount of installation space is necessa ry. When installing the rack, the indicated space (8 00mm of both the front and rear of t ...

  • Fujitsu XG1200 - page 25

    24 Installation and Operation Only use the XG1200 under t he temperature, humidity and other environmental cond itions specified in "A.2 Installation Specifications " (page 38). Using th e XG1200 outside the follow- ing ranges can shorten th e lifetime or cause th e failure of the XG1200. - Temperature (5 - 40°C ) - Humidity (20 - 80%RH) ...

  • Fujitsu XG1200 - page 26

    Inst allation Procedure 25 2 The following explains how to install the XG1200 in a 19-inch rack. 1. Take the XG1200 out of its box. 2. Fix the cage nuts and rails to the rack posts. 2-2-2 Installing the XG1200 in a rack Front Cage Nut Cage Nut [When the rack has square post holes (top view)] Rail Rail Rack Post Rack Post Rack Post Rack Post Rack Sc ...

  • Fujitsu XG1200 - page 27

    26 Installation and Operation 17:100 1:2 Front [When the rack has round post holes] Rack Post Rack Post Rack Post Rack Post Rack Nuts Rack Nuts Rack Nuts Rack Nuts Rail Rail Rack Screws (Large) Rack Screws (Large) Clip the rack nuts onto the rack post so that the holes are lined up. [When the rack has round post holes (top of view)] ¥¹¥±¡¼¥? ...

  • Fujitsu XG1200 - page 28

    Inst allation Procedure 27 2 3. Fix the four rack mounting brackets to t he XG1200. Each of the four rack moun ting bracket s (left, right, back-left, back-righ t) has th ree holes that should line up with matching holes on the sides of the XG1200, as sho wn in the diagram. Attach each rack mounting bracket using the countersunk bracket screws prov ...

  • Fujitsu XG1200 - page 29

    28 Installation and Operation 5. This completes the rack installation procedure. CAUTION As the XG1200 can weigh as much as 20kg, it should never be installed by a single person acting alone. At least two people sh ould work together to insert and fasten the XG1200 in the rack. The following explains how to unin stall the XG1200 from a rack. 1. Und ...

  • Fujitsu XG1200 - page 30

    Cable Connecti on 29 2 The fiber optic cab les need to be connected to the XG1200’s Xenpak modules . 1. Connect the fiber optic cables to the XG1200 . Connect the fibre optic cables to the Xenpa k mod ules Port 1 - Port 12 on th e front. Attention Attention • An fiber optic connect or is used when connecting two fi ber optic cables. When connec ...

  • Fujitsu XG1200 - page 31

    30 Installation and Operation After connecting the peripheral units, connect the XG1200 power cords. W ARNING • Never touch a po wer plug with wet hands, as there i s a risk of electr ic shock. • Do not damage or remodel a power cord, as this may cause electric sho ck or fire. Placing a heavy ob ject on, pulling, e xcessively bending, t wisting ...

  • Fujitsu XG1200 - page 32

    Cable Connecti on 31 2 2. Connect the power cord to the power ou tlet. Insert the plug at the other end of the power cord into the power strip or wall socket. W ARNING • Unplug the XG1200 du ring thunder-start ing. Continued u se under these condi tions risks lightning damage to the XG1200, and may cause a fire. • When you remove a power plug f ...

  • Fujitsu XG1200 - page 33

    32 Instal lation and Opera tion CAUTION Do not move, s hock, or vibrate th e XG1200 while it is on. 1. Turn the power switch to the "on" position by pressing the [ ] side. The Power LED (Green) on the front of the XG1200 should turn on. The Alarm LED (Orange) should turn on for a moment, then should turn off. The Status LED (Green) should ...

  • Fujitsu XG1200 - page 34

    Troubleshooting This chapter describes what you should do w hen your XG120 0 has problems . 3-1 S tart-up Problems .................................................................................... 34 3-2 Hardware Problems ................................................................................. 35 3 ...

  • Fujitsu XG1200 - page 35

    34 T roubleshoo ting [Symptom]The power switch is turn ed on, but the XG1200 does not po wer up. [Cause] Possible causes: 1: Loose cable, or 2: Hardware failure [Soluti on] 1: Check that all cables are connected prope rly, then (if the XG1200 stil l doesn’t turn on) 2: Contact the vendor' s service department. [Symptom] The XG1200 has not st ...

  • Fujitsu XG1200 - page 36

    Hardware Problems 35 3 When a problem is detected with a fan, the fr ont panel Alarm LED lights up in oran ge, the LED of the fan unit in which the error has occurred lights up in orange, and an error is recorded in the event log. If a fan error occurs, contact the vendor's service department. When XG1200 overheats, the Alarm LED light s up in ...

  • Fujitsu XG1200 - page 37

    36 T roubleshoo ting ...

  • Fujitsu XG1200 - page 38

    Appendix This appendix explains XG1200 specifications. Appendix-A S pecifications ............................................................................. 38 A.1 Product S pecifications ................................................................... 38 A.2 Installation S pecifications ....................................................... ...

  • Fujitsu XG1200 - page 39

    38 Appendix The product specifications of the XG1200 are as follows: The installation specifications of th e XG1200 are as follows: Appendix-A S pecifications This section details the specifications of XG120 0. A.1 Product Specifications Items Overview 10 Gigabit ports Port 1 - Port 12 IEEE802.3ae/ak co mpliant 10 Gigabit Etherne t port × 12 (for ...

  • Fujitsu XG1200 - page 40

    XG1200 Hardware Guide P3N1-E061-01 EN Date of issue: September 2005 Issuing authority: PFU LIMITED Printed in Japan • C ontents of this manual are not to be reproduced without permission from PFU. • The contents of this manual may be updated without notice. • P FU assumes no liability for damages to third party copyrights or other rights aris ...

メーカー Fujitsu カテゴリー Switch

Fujitsu XG1200のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- XG1200の取扱説明書
- Fujitsuの製品カード
- パンフレット
- またはFujitsu XG1200の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Fujitsu XG1200の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Fujitsu XG1200の取り付け説明書、サービスマニュアル、簡易説明書、またはFujitsu XG1200のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Fujitsu XG1200の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Fujitsu XG1200デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがFujitsu XG1200を使用するのを助ける技術的文書のことです。説明書は通常、全てのFujitsu XG1200ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Fujitsuの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Fujitsu XG1200の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははFujitsu XG1200の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Fujitsu XG1200に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Fujitsu XG1200デバイスの基本機能を使うにあたってのヒント。 Fujitsu XG1200のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Fujitsu XG1200に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるFujitsu XG1200のメーカー/サービスへの連絡先に関する情報。

Fujitsu XG1200についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもFujitsu XG1200の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがFujitsu XG1200で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)