    HAL100PID HITACHI INVERTER PID CONTROL USERS ’ GUIDE After reading this manual, keep it for future reference Hitachi America, Ltd. SJ/L100/300 SERIES ...

  • Hitachi L100 300 - page 2

    SJ100/L100 / PID / 2 CONTENTS 1. OVERVIEW 3 2. PID CONTROL ON SJ100/L100 INVERTERS 3 2-1 PID Control 3 (1) P : Proportional Control 4 (2) I : Integral Control 5 (3) D : Differential Control 5 (4) PID Control 5 2-2 PID Gain Adjustments & Control Characteristics 6 3. HOW TO USE 7 3-1 Structure & Parameters 7 (1) Control Mode 7 (2) Parameters ...

  • Hitachi L100 300 - page 3

    SJ100/L100 / PID / 3 1. OVERVIEW SJ100/L100 series inverters have an integrated PID control function as standard. They can be used for controls, such as constant flow control for fan & pump applications, and they have the following features. l Target signal can be given not only by the digital operator but also by an external digital signal, wh ...

  • Hitachi L100 300 - page 4

    SJ100/L100 / PID / 4 SJ100/L100 series inverters have integrated PID control, which is indicated by the dotted line in Fig. 2-1. You can use PID control by setting a target value and providing a feedback signal. The example in Fig. 2-2 shows a connection diagram for ventilation flow control in a fan application. (1) P : Proportional Control This co ...

  • Hitachi L100 300 - page 5

    SJ100/L100 / PID / 5 (2) I: Integral Control This is a control to correct the output frequency by integrating the deviation. In the case of proportional adjustment, a large deviation will result in a large output frequency adjustment, but if the deviation is small, then the resulting adjustment of output frequency will also be small. However, you c ...

  • Hitachi L100 300 - page 6

    SJ100/L100 / PID / 6 2-2 PID Gain Adjustments & Control Characteristics The optimal gain factors of PID vary from condition to condition, and from system to system. That means it is necessary to set those parameters by taking into account the individual control characteristics of your particular system. The following are the characteristics tha ...

  • Hitachi L100 300 - page 7

    SJ100/L100 / PID / 7 3. HOW TO USE 3-1 Structure & Parameters (1) Control Mode Integrated operator A71 : 00 / 01 DOP, DRW F43 : PID SW ON / OFF SJ100/L100 series inverters feature the following two control modes: l Frequency control mode l PID control mode These can be selected by “ PID function selection (A71) ” . Frequency control mode is ...

  • Hitachi L100 300 - page 8

    SJ100/L100 / PID / 8 (3) Deviation Calculation Every calculation in PID control in the SJ100/L100 is based on “ % ” so that it can be used with various applications and units of measure, such as pressure (N/m 2 ), flow (m 3 /min), temperature (degrees) and so on. For example, comparing target value and feedback value is based on % of target and ...

  • Hitachi L100 300 - page 9

    SJ100/L100 / PID / 9 As you can see from Fig 3-3, if you set parameters A11 and A12 other than “0”, you should set the target value inside the valid range of the vertical axis. Otherwise it is not possible to achieve stable performance because there is no feedback value. That means the inverter will either output maximum frequency or stop, or i ...

  • Hitachi L100 300 - page 10

    SJ100/L100 / PID / 10 3-2 Summary of Parameters for PID Control On the SJ100/L100 series inverters, the same function numbers are used for both frequency control mode and PID control mode. The function name for each function is based on frequency control mode, which is normally used for general application. Therefore, some functions have misleading ...

  • Hitachi L100 300 - page 11

    SJ100/L100 / PID / 11 3-3 Example of Set Up (1) Parameter Set Up under Frequency Control Mode Before driving the system in PID mode, you set up each required parameter under frequency control mode. Pay particular attention to the following items. l Acceleration ramp and Deceleration ramp The output of the PID calculation (refer to Fig. 3-1) will no ...

  • Hitachi L100 300 - page 12

    SJ100/L100 / PID / 12 (3) Scale Conversion Factor Setting Set this factor according to your application, e.g. flow, pressure, temperature and so on. For a detailed explanation, please refer to item (6) on page 9. (4) Target Input by Digital Input Signal Please refer to the following when changing the target with the digital input signal ( 4 bit max ...

  • Hitachi L100 300 - page 13

    SJ100/L100 / PID / 13 3-4 Example of Each Gain Adjustment ( K p & T i ) l Check the response of feedback signal or the output frequency of the inverter when making a step change in the target. (Please refer to Fig. 2-4) l Use an oscilloscope or other measuring equipment to observe the waveform of the feedback value or output frequency of the in ...

  • Hitachi L100 300 - page 14

    SJ100/L100 / PID / 14 4. EXAMPLE OF ACTUAL APPLICATION You can find in this chapter some typical setting examples for actual applications. 4-1 Constant Flow Control In this case (targets are 150m 3 /min & 300m 3 /min), the settings would be as follows: Function Number Function Name Input Remarks Integrated Operator DOP, DRW Under PID Control Mo ...

  • Hitachi L100 300 - page 15

    SJ100/L100 / PID / 15 4-2 Constant Temperature Control In the case of constant flow control shown in the previous section, output frequency of the inverter increases if the feedback value is smaller than target value, and output frequency of the inverter decreases if the feedback value is bigger than the target value. However, in the case of consta ...

  • Hitachi L100 300 - page 16

    SJ100/L100 / PID / 16 5. INDEX - A - - R - acceleration ramp 11 response 6 AVR function 13 - S - - C - scale conversion 9 control mode 7, 10 steady state deviation 6 - D - - T - damped oscillation 6 target 8 deceleration ramp 11 target input 12 deviation 3, 8 target origin input 11 differential control 5 differential gain ( Kd : D-gain) 5 divergenc ...

メーカー Hitachi カテゴリー Power Supply

Hitachi L100 300のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- L100 300の取扱説明書
- Hitachiの製品カード
- パンフレット
- またはHitachi L100 300の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Hitachi L100 300の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Hitachi L100 300の取り付け説明書、サービスマニュアル、簡易説明書、またはHitachi L100 300のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Hitachi L100 300の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Hitachi L100 300デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがHitachi L100 300を使用するのを助ける技術的文書のことです。説明書は通常、全てのHitachi L100 300ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Hitachiの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Hitachi L100 300の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははHitachi L100 300の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Hitachi L100 300に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Hitachi L100 300デバイスの基本機能を使うにあたってのヒント。 Hitachi L100 300のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Hitachi L100 300に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるHitachi L100 300のメーカー/サービスへの連絡先に関する情報。

Hitachi L100 300についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもHitachi L100 300の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがHitachi L100 300で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)