    12/15/05 1 600 Series Industrial Ethernet Switches Hardware Installation Guide ...

  • N-Tron 608MFXE-ST-40 - page 2

    12/15/05 2 Industrial Ethernet Switch In stallation Guide 604MFX-ST 604MFXE-ST-15 604MFXE-ST-40 604MFXE-ST-80 608MFX-ST 608MFXE-ST-15 608MFXE-ST-40 608MFXE-ST-80 ...

  • N-Tron 608MFXE-ST-40 - page 3

    12/15/05 3 Copyright, © N-TR ON Corp., 2002 820 S. University B lvd., Suite 4E Mobile, AL USA 3 6609 All rights reserved. Rep roduction, adaptation , or translation without p rior written permission from N-TRON Co rp. is prohibited, ex cept as allowed u nder copyright laws . Ethernet is a registered trademark of Xerox Corporatio n. All other pro d ...

  • N-Tron 608MFXE-ST-40 - page 4

    12/15/05 4 Safety Warnings ELECTRICAL SAFETY WARNING: Disconnect the power cable before removing the enclosure top. WARNING: Do not operate the unit with the top cover removed. WARNING: Do n ot work o n equipment o r cables du ring periods of lightning activity. WARNING: Do not perform any services on the unit unless qu alified to do so. WARNING: D ...

  • N-Tron 608MFXE-ST-40 - page 5

    12/15/05 5 600 Series Industrial Ethernet Switch The N-TRON 600 Series are product derivatives of the OSM/ESM family jointly manufactured by Siemens and N-TRON. The N-TRON 600 Series switches supports high speed layer 2 switching between ports, and is housed in a ruggedized steel enclosure, and can withstand industrial temperatures, as well as high ...

  • N-Tron 608MFXE-ST-40 - page 6

    12/15/05 6 PACKAGE CONTENTS Please make sure the Ethernet Switch package contains the following items: 1. 600 Series Ethernet Switch 2. This Installation Guide Contact your carrier if any items are damaged. INSTALLATION Read the following warning before beginning the installation: WARNING The FXE units contain a class 1 laser. Do not stare into the ...

  • N-Tron 608MFXE-ST-40 - page 7

    12/15/05 7 600 Series Hazardous Location Installation Requirements 1. WARNING! Do not disconnect while circuit is live, unless area is known to be non-hazardous. 2. WARNING! Install only in accordance with Local & National Codes of .Authorities Having Jurisdiction. 3. Class I, Div 2 installation requires that all devices connected to this produ ...

  • N-Tron 608MFXE-ST-40 - page 8

    12/15/05 8 APPLYING POWER 1. Unscrew the flange & remove the DC Voltage Input Plug from the Header. 2. Install the DC Power Cables into the Plug(s) (observing polarity per the legend on the top of the unit). L1+ and L2+ are the +24V connections. M1 and M2 are the minus (-) returns for the L1 and L2 respectively. F1 and F2 terminals are across t ...

  • N-Tron 608MFXE-ST-40 - page 9

    12/15/05 9 CONNECTING THE STANDARD RING Remove the dust cap from the f iber optic connectors and connect the fiber optic cables. Please refer to the Figure 1. Diagram. To begin the ring, the TX out-port #7 should be connected to the RX in-port #8 of the far end station. The RX in- port #7 should be connected to the TX out-port #8 on the far end sta ...

  • N-Tron 608MFXE-ST-40 - page 10

    12/15/05 10 For 10/100 Base-TX ports, plug a Category 5 (or better) twisted pair cable into one the RJ45 copper ports (1-6 ). Connect the o ther end to the far end st ation. Verify that the Port L ED’s are ON once the connection has been completed. For Switch to Switch o r Switch to Repeater connections, a crossov er cable may be required if the ...

  • N-Tron 608MFXE-ST-40 - page 11

    12/15/05 11 608MF X R I N G MA N A G E R 608 MFX Ne two rk Seg ment R edu nd an cy Figu re 2 608M FX 608M FX Sta n d b y M as t e r FIBER OP T IC P A IR FIBER OP T IC P A IR FIBER OP TIC PA IR #7 #8 #7 #8 # 7 #8 #7 #8 608M FX Stan d by Slave 608M FX 608M FX FIBER OP T IC P A IR FIBER OP TIC PA IR #7 #8 # 7 #8 608M FX 608MF X R I N G MA N A G E R FI ...

  • N-Tron 608MFXE-ST-40 - page 12

    12/15/05 12 DISPLAYS AND OPERATING CONTROLS LED’s Fault (red LED) Status Meaning ON The 604/608MFX has detected an error. The signaling contact opens at the same time. OFF No errors detected by the 604/608MFX. Stby - Standby (green LED, 608MFX Only) Status Meaning ON The 608MFX standby function is activated, indicating the 608MFX is in the standb ...

  • N-Tron 608MFXE-ST-40 - page 13

    12/15/05 13 Port LED’s The display Mode is indicated by the LED pair labeled “Display Mode”, and the state is given by th e legend on the front of the 600 Series Switch. To transition between these Display Modes, the Select/Set button must be pressed briefly (similar to left mouse click). The four states are: Port Status, 100Mbit/s, Full Dupl ...

  • N-Tron 608MFXE-ST-40 - page 14

    12/15/05 14 “Select/Set” Button The Select/Set” multi-functional button on the front panel of the 604/608MFX performs the following actions: • Pressing the button briefly (similar to left mouse click) transitions the display of the two display mode LED’s. The current display mode is indicated by the status of the display mode LED’s per ...

  • N-Tron 608MFXE-ST-40 - page 15

    12/15/05 15 Aging Time The 604/608MFX monitors the ag e of the addresses it h as learnt, an d addresses that exceed a certain age (aging time, default setting = 40 sec), are deleted again by the sw itch. If a p acket with a source address matching the address entry is received before the aging time elapses, the address entry is retained, and th e a ...

  • N-Tron 608MFXE-ST-40 - page 16

    12/15/05 16 Serial Interface The 604/608MFX provides an EIA-2 32 in terface accessed via a 9 pin male connector (labeled V24 on the unit). This is used to access the Command Line Interpreter (CLI). Functions in clude setting the IP address, and other parameters ( see Network Management Users guide). Th e pin-outs are shown below: DSR Pin 6 RTS Pi n ...

  • N-Tron 608MFXE-ST-40 - page 17

    12/15/05 17 Serial Cable Connect the serial COM port of your PC and the 600 Ser ies Switch u sing a normal n ull modem cable (or a straight through cable with a null modem adapter). You will require a cable with a 9 -pin or 25-pin sub-D female connector for th e PC end , and a 9-pin female su b-D connector for the 608MFX end. The fo llowing table s ...

  • N-Tron 608MFXE-ST-40 - page 18

    12/15/05 18 TROUBLESHOOTING 1. Make sure the Power LED (L1 and/or L2) is ON. 2. Make sure the Voltage is within specifications (18-32V@1A). 3. Make sure the fiber ports and TX ports are properly connected. 4. Verify that Port LED’s are ON for connected ports. 5. Verify the status of the fault (RM) LED. 6. Verify cabling (pin-outs & integrity) ...

  • N-Tron 608MFXE-ST-40 - page 19

    12/15/05 19 KEY SPECIFICATIONS Physical Height: 5.5" (13.65 cm) Width: 8.55" (21.70 cm) Depth: 2.75" (6.90 cm) Weight: 3.08 lbs (1.4 kg ) Electrical Input Voltage: 18-32 VDC (Redundant inputs) Input Current: 1.0A @ 24V Power Consumption: 24 Watts @24V Environmental Operating Temperature: 0°C to 60°C Storage Temperature: -40°C to 8 ...

  • N-Tron 608MFXE-ST-40 - page 20

    12/15/05 20 Key Specifications (Cont.) Emissions and Safety Approvals: FCC Part 15 Class A CE, UL, FM Class 1 Div 2 Groups A,B,C,D Note: Shielded cables must be used to meet emission standards. Ordering Information PN Description 604MFX-ST Industrial Ethernet Switch, ST Fiber Connectors, 608MFX-ST MM, 2km 604MFXE-ST-YY Industrial Ethernet Switch, S ...

  • N-Tron 608MFXE-ST-40 - page 21

    12/15/05 21 N-TRON Limited Warrant y N-TRON, Corp. warra nts to the end user that this hardwa re product will be free from defects in workmanship and materials, under normal use and service, for the applicable war ranty period from the data of purchase from N-TRON or its authorized reseller. If a product does not operate as warranted during the app ...

  • N-Tron 608MFXE-ST-40 - page 22

    12/15/05 22 AND NON-INFRINGEMENT, ALL OF WHICH ARE EXPRESSLY DISCLAIMED. N-TRON NEIT HER ASSUMES NOR AUTHORIZ ES ANY OTHER PERSON TO ASSUME FOR IT ANY OTHER LIAB ILITY IN CONNECTION WITH THE SALE , INSTALLATION, MAINTENANCE OR US E OF ITS PRODUCTS. N-TRON SHALL NOT BE LIABLE UNDER T HIS WARRANTY IF ITS TE STING AND EXAMINATION DISCLOSE THAT THE ALL ...

メーカー N-Tron カテゴリー Switch

N-Tron 608MFXE-ST-40のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 608MFXE-ST-40の取扱説明書
- N-Tronの製品カード
- パンフレット
- またはN-Tron 608MFXE-ST-40の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、N-Tron 608MFXE-ST-40の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、N-Tron 608MFXE-ST-40の取り付け説明書、サービスマニュアル、簡易説明書、またはN-Tron 608MFXE-ST-40のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、N-Tron 608MFXE-ST-40の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

N-Tron 608MFXE-ST-40デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがN-Tron 608MFXE-ST-40を使用するのを助ける技術的文書のことです。説明書は通常、全てのN-Tron 608MFXE-ST-40ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

N-Tronの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. N-Tron 608MFXE-ST-40の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははN-Tron 608MFXE-ST-40の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。N-Tron 608MFXE-ST-40に関してこのドキュメントで見つけることができる全てのヒントの目次
3. N-Tron 608MFXE-ST-40デバイスの基本機能を使うにあたってのヒント。 N-Tron 608MFXE-ST-40のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。N-Tron 608MFXE-ST-40に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるN-Tron 608MFXE-ST-40のメーカー/サービスへの連絡先に関する情報。

N-Tron 608MFXE-ST-40についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもN-Tron 608MFXE-ST-40の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがN-Tron 608MFXE-ST-40で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)