    Answers for energy . T ype V ector® manual group-operated switch inst r uction manual Installation operation maintenance E50001-F710-A420-X-4A00 ...

  • Siemens E50001-F710-A420-X-4A00 - page 2

    Important The information contained her ein is general in nature and no t intended f or specific application purposes. It does not reliev e the user of responsibility t o use sound practices in application, installation, operation and maintenance of the equipment purc hased. Siemens reserves the right to mak e changes in t he specifications shown h ...

  • Siemens E50001-F710-A420-X-4A00 - page 3

    T able of contents Introduction 4 - 5 General description 6 - 7 Receiving, handling and storage 8 - 10 Installation 11 - 12 Operating handle adjustment procedure 13 Operational check out instructions 14 - 15 Maintenance 16 - 17 Note: These instructions do not purport to cov er all details or variations in equipment, nor to pr ovide f or every possi ...

  • Siemens E50001-F710-A420-X-4A00 - page 4

    Int roduction Introduction The type V ector® manual gr oup-operated switch is designed to mee t all applicable ANSI, NEMA and IEEE standards. Successful application and operation of this equipment depends as much upon proper installation and maintenance b y the user as it does upon the proper design and fabrication by Siemens. The purpose of this ...

  • Siemens E50001-F710-A420-X-4A00 - page 5

    Int roduction Signal words The signal words "dang er ," "warning" and "caution" used in this instruction manual indicate the deg ree of hazard t hat may be encounter ed by the user . These words ar e defined as: Danger - Indicates an imminently hazardous situation which, if no t av oided, will result in death or seriou ...

  • Siemens E50001-F710-A420-X-4A00 - page 6

    General descr iption Introduction Siemens type V ector® manual gr oup- operated air switch is pr ecision built equipment designed to function efficiently under normal operating conditions. It is designed and manufactured t o operate within the paramet ers established in ANSI/ IEEE and NEMA standards for disconnecting and load-interrup ter switches ...

  • Siemens E50001-F710-A420-X-4A00 - page 7

    General descr iption Scope These instructions cover the installation, operation and maintenance of a Siemens type V ector® manual gr oup-operated air switch. The equipment designs described in this instruction manual consists of group-operat ed air switch f or application up to 38.0 kV . A typical type V ector manual group-operat ed air switch is ...

  • Siemens E50001-F710-A420-X-4A00 - page 8

    Receiving, handling and storag e Receiving Each type V ector® manual g roup-operated air switch is securely bloc ked and braced for shipment on a palle t. It is crated, bo xed or cover ed as req uired by shipping conditions. If special handling is requir ed, it is so indicated. The type V ector manual group-operat ed air switch must be handled car ...

  • Siemens E50001-F710-A420-X-4A00 - page 9

    Receiving, handling and storag e 3. Any visible damage must be no ted on the delivery receipt and acknow ledged with the driver’s signature. The damage should be detailed as much as possible. It is es sential that a notation "possible int ernal damage, subject to inspection" be included on delivery receipt. If t he driver will no t sign ...

  • Siemens E50001-F710-A420-X-4A00 - page 10

    Receiving, handling and storag e Lifting and moving There ar e a number of methods that can be used in handling the type V ector® manual group-operat ed switch that, when properly em ployed, will no t damage the type V ector manual gr oup-operated switch. The handling met hod used will be det ermined by conditions and a vailable equipment at the i ...

  • Siemens E50001-F710-A420-X-4A00 - page 11

    Installation Installation Installation instructions for the type V ector manual group-operat ed air switch are detailed in the f ollowing steps: 1. Drill two mounting holes 11/16" in diamet er located per the user's construction standards and spaced per Siemens assembly dra wing. 2. Install the mounting bolts in the holes. Mounting bolts ...

  • Siemens E50001-F710-A420-X-4A00 - page 12

    Installation 8. Remove sing le-point lift bracket. 9. Ground the air switc h unit (and surge arresters if r equired) using #2 or lar ger copper wire. A gr ounding point (1/2-13 tapped hole) is provided in the side of the mounting brack et (r efer t o assembly dra wing provided). 10. Mount pipe guides and lock segment assemblies in position per user ...

  • Siemens E50001-F710-A420-X-4A00 - page 13

    Operating handle adjust ment procedur e Operating handle adjustment procedure The next series of steps addr ess adjusting the position of the handle assembly and lock segment assembly so t hat the handle can be inserted into the OPEN and CL OSED slot corr ectly . Important : It is extremely im port ant t o adjust the handle position so it is imposs ...

  • Siemens E50001-F710-A420-X-4A00 - page 14

    Operational chec k out inst ructions Operational check out instructions Operational check out instructions f or the type V ector® manual gr oup-operated switch are de tailed in the follo wing steps: 1. Switches are fully adjusted and inspected before the y lea ve the factory . There should be no need t o adjust the switch unit. 2. Check the r otat ...

  • Siemens E50001-F710-A420-X-4A00 - page 15

    Operational chec k out inst ructions 2. As the blade continues t o ro tate open, the interrup ter le ver must make full me tal-to-me tal contact with the contactor (ref er to Figur e 13: Contactor connection). At this point, t he load then transfers fr om the auxiliar y contacts to the interrup ter's lev er arm so that the interrup ter now car ...

  • Siemens E50001-F710-A420-X-4A00 - page 16

    Maintenance Maintenance Maintenance instructions f or the type V ector® manual gr oup-operated switch ar e detailed in the f ollowing steps: 1. Periodically operate the switc h and check f or actions described in Operational check out instructions on pages 14-15. Lubricate the ja w , auxiliar y contacts and the end of the blade with Dow Corning® ...

  • Siemens E50001-F710-A420-X-4A00 - page 17

    Maintenance T able 2: Remarks 17 ...

  • Siemens E50001-F710-A420-X-4A00 - page 18

    www .usa.siemens.com/energy Published by and copyright © 2011: Siemens AG Energy Sector Fr eyeslebenstras se 1 91058 Erlangen, Germany Siemens Energy , Inc. 99 Bolton Sullivan Drive Heber Springs, AR 72543 For more inf ormation, contact +1 (800) 347-6659 +1 (501) 362-8296 Order No. E50001-F710-A420-X -4A00 Replaces No. VEC4100 10/2/08 Printed in U ...

メーカー Siemens カテゴリー Switch

Siemens E50001-F710-A420-X-4A00のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- E50001-F710-A420-X-4A00の取扱説明書
- Siemensの製品カード
- パンフレット
- またはSiemens E50001-F710-A420-X-4A00の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Siemens E50001-F710-A420-X-4A00の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Siemens E50001-F710-A420-X-4A00の取り付け説明書、サービスマニュアル、簡易説明書、またはSiemens E50001-F710-A420-X-4A00のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Siemens E50001-F710-A420-X-4A00の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Siemens E50001-F710-A420-X-4A00デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがSiemens E50001-F710-A420-X-4A00を使用するのを助ける技術的文書のことです。説明書は通常、全てのSiemens E50001-F710-A420-X-4A00ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Siemensの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Siemens E50001-F710-A420-X-4A00の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははSiemens E50001-F710-A420-X-4A00の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Siemens E50001-F710-A420-X-4A00に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Siemens E50001-F710-A420-X-4A00デバイスの基本機能を使うにあたってのヒント。 Siemens E50001-F710-A420-X-4A00のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Siemens E50001-F710-A420-X-4A00に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるSiemens E50001-F710-A420-X-4A00のメーカー/サービスへの連絡先に関する情報。

Siemens E50001-F710-A420-X-4A00についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもSiemens E50001-F710-A420-X-4A00の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがSiemens E50001-F710-A420-X-4A00で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)