  • Vermont Casting VL24 - page 1

    Installation and Operation Instructions for V ent-Free Gas Log Sets* Models: VL18, VL21 and VL24 (Natural Gas) VL18LP , VL21LP and VL24LP (Propane) CERTIFIED D E S I G N C E R T I F I E D 20002538 1/07 Rev . 8 *These logsets are not for exterior use. W A R N I N G If the information in this manual is not followed exactly , a fire or explosion may ...

  • Vermont Casting VL24 - page 2

    2 20002538 The Logsets have been designed and tested to operate safely when installed according to the installation instructions con- tained in this manual. Read all instructions before starting the installation. In the Commonwealth of Massachusetts, all gas fitting and installation of this heater shall only be done by a licensed gas fitter or li ...

  • Vermont Casting VL24 - page 3

    3 20002538 Installation Requirements The fireplace must meet the minimum dimensions listed below . (Fig. 1) Do not install the logset if the fireplace does not meet these minimums. Pressure T est Points Copreci V alve: 1/8” N.P .T . plugged tapping is provided on the outlet side of the gas control for a test manifold pressure. SIT V alve: Inlet ...

  • Vermont Casting VL24 - page 4

    4 20002538 Planning Planning the installation is an important first step. It will save time and money later in the actual installation. In planning the installation, consider: • Where the heater will be located. • All components needed to complete the installation. • DO NOT use this heater in bedrooms, bathrooms, mobile homes or in recreatio ...

  • Vermont Casting VL24 - page 5

    5 20002538 Installation Requirements WARNING This heater must have fresh air for proper opera- tion. If it does not, poor fuel combustion could result. Read the following instructions to ensure proper fresh air supply for this and other fuel- burning appliances in your home. Modern construction standards have resulted in homes that are highly energ ...

  • Vermont Casting VL24 - page 6

    6 20002538 WARNING This heater shall not be installed in a confined space or unusually tight construction unless provisions are made for adequate combustion and ventilation air . WARNING If the area in which the heater may be operated is smaller than that defined as an unconfined space, or if the building is of unusually tight construction, prov ...

  • Vermont Casting VL24 - page 7

    7 20002538 W ARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns. W ARNING: Do not use a blower insert, heat ex - changer insert or other accessory not approved for use with this gas logset. Do not burn solid fuels in a fireplace where an unvented gas room heater or logset is installed ...

  • Vermont Casting VL24 - page 8

    8 20002538 Damper Stop Installation When installing a decorative gas appliance in a fire- place, some local codes require a damper stop be added so the damper will not close completely . The CFM Corporation damper stop is designed so the damper can be locked in the closed position, and still allow a vent for the pilot gasses. This damper stop is d ...

  • Vermont Casting VL24 - page 9

    9 20002538 Burner Assembly Location Centrally locate the unit in the fireplace, far enough back into the firebox to accomplish adequate draft (if use as a vented appliance is planned). Ensure the front grate feet sit inside the front edge of the fireplace a minimum of 3 ¹⁄₄ ”. (Fig. 6b) Gas Line Connection Check the gas type. Use only the ...

  • Vermont Casting VL24 - page 10

    10 20002538 Check the inlet pressure to the appliance, to ensure that it is as shown in the table on page 3. The minimum is for the purpose of input adjustment. The pressure is controlled by the regulator and should be checked at the pressure test point located in the control valve body . Access to the pressure test point is obtained by removing al ...

  • Vermont Casting VL24 - page 11

    1 1 20002538 LG100 VL18 logset  3/26/99  changed burner 4/3/00 djt Locator Pins Locator Pin Grate LG100 Locator Pin Fig. 7 VL18 log placement. LG102 VL21 logset  3/31/99  modified burner/grate 4/3/00 djt Locator Pins Grate LG102 Locator Pin Locator Pin Fig. 8 VL21 log placement. LG104 VL24 logset  4/1/99  modified burner ...

  • Vermont Casting VL24 - page 12

    12 20002538 3. Open control access panel. 4. Push in gas control knob slightly and turn clock- wise to “OFF”. Do not force. 5. Close control access panel. 1. STOP! Read the safety information above. 2. Turn of f all electrical power to the fireplace. 3. For MN/MP/TN/TP appliances ONL Y , go on to Step 4. For RN/RP appliances turn the On/Of f s ...

  • Vermont Casting VL24 - page 13

    13 20002538 When Used as a Heating Appliance 1. This appliance is equipped with a modulating valve which provides variable control of heat output, from approximately 15,000 or 18,000 BTU/hr at the full counterclockwise LOW position, to 24,000, 32,000 or 35,000 BTU/hr at the HIGH position, depending on your appliance. See page 3 for output of your a ...

  • Vermont Casting VL24 - page 14

    14 20002538 LF103� VL21 flames � 3/31/99 � changed valve 4/14/00 djt HI OFF PILO T LO LF101� VL18 flames � 3/29/99 � changed valve 4/13/00 djt HI OF F PILO T LO 7” - 9” Approx. 7” - 9” Approx. 6” - 8” Ap - prox. LG101 LG103 LG105 VL24 VL21 VL18 LF105� VL24 flames � 4/1/99 � changed valve 4/14/00 djt HI OF F PILO T LO 7 ...

  • Vermont Casting VL24 - page 15

    15 20002538 T roubleshooting With proper installation and maintenance, your new Gas Appliance should provide years of trouble-free ser- vice. If you do experience a problem, this guide will assist a CERTIFIED SERVICE PERSON in the diag- nosis of problems and the corrective action to be taken. Symptom Possible Causes Corrective Action Pilot will not ...

  • Vermont Casting VL24 - page 16

    16 20002538 1 a b c d HI OFF PILO T LO 2 3 4 5 6a,b 10a,b 7 8 9 1 1a,b 12a,b 13a,b 15a,b 2538 VL18,21,24,30 replacement parts 4/4/00 djt 14 16a,b 17 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. 2538 VL18/21/24 Standard V ent Free Gas ...

  • Vermont Casting VL24 - page 17

    17 20002538 Contact the factory for questions concerning prices and policies covering replacement parts. Parts will be shipped at prevailing prices. Normally , all parts can be ordered through your CFM Corporation distributor or dealer . When ordering replacement parts, always give the fol- lowing information: •The model number of the appliance. ...

  • Vermont Casting VL24 - page 18

    18 20002538 Model No. Accessories The following accessories are available from your CFM Corporation dealer . Should you need additional information beyond what your dealer can furnish, contact CFM Corporation, 410 Admiral Blvd. Mississauga, Ontario, Canada L5T 2N6, Attention: T echnical Service. Accessory Description Required to protect wall above ...

  • Vermont Casting VL24 - page 19

    19 20002538 MERCHANT ABILITY OR FITNESS FOR A P ARTICULAR PURPOSE), ALL OF WHICH ARE HEREBY EXPRESSL Y INCLUDED. IN NO EVENT SHALL ANY IMPLIED W AR - RANTY PRESCRIBED BY LA W (NOTWITHST ANDING THE FOREGOING EXPRESS EXCLUSION) REMAIN IN EF- FECT AFTER EXPIRA TIONS OF THE W ARRANTIES SET FORTH IN P ARAGRAPHS A AND B. A. Gas Appliances, electrical and ...

  • Vermont Casting VL24 - page 20

    © CFM Corporation 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 800-668-5323 • www .cfmcorp.com CFM Corporation ...

メーカー Vermont Casting カテゴリー Indoor Fireplace

Vermont Casting VL24のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- VL24の取扱説明書
- Vermont Castingの製品カード
- パンフレット
- またはVermont Casting VL24の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Vermont Casting VL24の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Vermont Casting VL24の取り付け説明書、サービスマニュアル、簡易説明書、またはVermont Casting VL24のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Vermont Casting VL24の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Vermont Casting VL24デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがVermont Casting VL24を使用するのを助ける技術的文書のことです。説明書は通常、全てのVermont Casting VL24ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Vermont Castingの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Vermont Casting VL24の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははVermont Casting VL24の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Vermont Casting VL24に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Vermont Casting VL24デバイスの基本機能を使うにあたってのヒント。 Vermont Casting VL24のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Vermont Casting VL24に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるVermont Casting VL24のメーカー/サービスへの連絡先に関する情報。

Vermont Casting VL24についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもVermont Casting VL24の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがVermont Casting VL24で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)