Honeywell Y343B1002の取扱説明書

11ページ 1.07 mb
ダウンロード

ページに移動 of 11

Summary
  • Honeywell Y343B1002 - page 1

    Honevwell THE Y343B IGNITION PACKAGE PROVIDES DIRECT SPARK IGNITION (DSI) FOR GAS HEATING SYSTEMS. THE PACKAGE IN- CLUDES THE S87D ELECTRONIC MODULE, Q354A FLAME SENSOR, Q347A SPARK IG- NITER-SENSOR AND 392286-l IGNITION CABLE. DEPENDABLE BURNER IGNITION 0 Spark generated by electronic module and internal step-up transformer. SOLID STATE DESIGN 17 ...

  • Honeywell Y343B1002 - page 2

    SPECIFICATIONS 4 The Y34381002 Direct Soark Gas Burner lanition Package includes the S87D ilectronic Module, 6347A Spark Igniter-Sensor, Q354A Flame Sensor and 392286-l Ignition Cable Assembly. Other controls needed to complete the heating sys- tem include a 24 V, DSI gas valve; 24 V thermostat; 24 V transformer and high temperature limit controlle ...

  • Honeywell Y343B1002 - page 3

    AMBIENT TEMPERATURE RATING: Minus 40 F to plus 175 F [minus 40 C to plus 79 C]. WIRING CONNECTIONS: l/4 in. [6.4 mm] male quick-connect terminals, for all except ALARM ter- minal. ALARM terminal, l/4 in. [6.4 mm] female quick-connect. l/4 in. [6.4 mm] diameter stud base for ignition cable. REPLACEMENT PARTS: 3 A fuse. Q347A SPARK IGNITER-SENSOR The ...

  • Honeywell Y343B1002 - page 4

    TABLE l-GAS CONTROLS. MODEL NO. V845A VR8450A V845C VR8450C VR8540A VR8590A VR8600A TYPE OF PRESSURE REGULATOR Standard Standard Step-open Step-open Two-stage Negative Negative CAPACITY RANGE OF STANDARD MODEL cfh mJ/hr 110to335 3.1 to 9.5 110to290 3.1 to 7.8 11oto335 3.1 to 9.5 110to290 3.1 to 7.8 110to290 3.1 to 7.8 37 to 400 1.oto 11.3 37 to 400 ...

  • Honeywell Y343B1002 - page 5

    Position the Q347 so that only the tips of the elec- trodes are immersed in the burner flame. The burner must ignite smoothly - usually this will be ac- complished with tip of electrodes (spark gap) spaced approximately l/4 in. [6.4 mm] from the surface of the burner. Gas must flow into one of the three open sides of the spark gap (where outer elec ...

  • Honeywell Y343B1002 - page 6

    Q354A FLAME SENSOR 1. Mate quick-connect terminals (l/4 in. [6.4 mmf)’ are provided on both the Q354 and S87D. Connect the SENSOR terminal on the 587 to the terminal on the Q354 as shown in Fig. 4. Use thermoplastic insulated wire with a minimum rating of 105 C [221 F] for the flame sensor leadwire; asbestos insulation is not acceptable. AUXILIAR ...

  • Honeywell Y343B1002 - page 7

    FIG. B-WIRING HOOKUP FOR Y343B PACKAGE IN A TYPICAL TWO-STAGE DSI HEATING SYSTEM. ,, “,, ~ ,,, I ,,,, ,. ,.., :. II ,, , .xI,. j ,,,. ., _ ,-, CI ,x .,,, ., . .x _^.,” ~.. ,, ,IX ^ _, FIG. 7-S67D SIMPLIFIED SCHEMATIC DIAGRAM. 7 66-00?4 ...

  • Honeywell Y343B1002 - page 8

    STARTUP AND CHECKOUT The following start-up and checkout procedures are basic to the S87. If possible, refer to the specific instructions provided by the appliance manufacturer since the application and controls used may differ. NOTE: If one of the system components fails, the S87 will either not operate or it will go into safety lockout (depending ...

  • Honeywell Y343B1002 - page 9

    FIG. a--NORMAL SYSTEM SEQUENCE OF OPERATION. SERVICE l Only persons trained and experienced in DSI systems should service this equipment. If a condition exists that causes the S87D electronic module to go into safety lockout, meter readings must be taken quickly after restart - within trial-for-ignition period. Always de-energize the system for at ...

  • Honeywell Y343B1002 - page 10

    GROUNDING CONNECTIONS A common ground is required for the burner, spark igniter-sensor mounting bracket and the GND terminal of the 587. If ground is poor or erratic, safety shutdown may occur occasionally even though operation is nor- mal at time of checkout. Therefore, if nuisance shut- downs have been reported, be sure to check ground connection ...

  • Honeywell Y343B1002 - page 11

    t TROUBLESHOOTING . Start the system by setting the thermostat (tem- down to the next box. If the condition is not true or not perature controller) to call for heat. Observe the system okay (answer is no), go to the box at right. Continue response and establish the type of malfunction or checking and answering conditions in each box until a deviati ...

メーカー Honeywell カテゴリー Burner

Honeywell Y343B1002のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- Y343B1002の取扱説明書
- Honeywellの製品カード
- パンフレット
- またはHoneywell Y343B1002の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Honeywell Y343B1002の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Honeywell Y343B1002の取り付け説明書、サービスマニュアル、簡易説明書、またはHoneywell Y343B1002のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Honeywell Y343B1002の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Honeywell Y343B1002デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがHoneywell Y343B1002を使用するのを助ける技術的文書のことです。説明書は通常、全てのHoneywell Y343B1002ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Honeywellの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Honeywell Y343B1002の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははHoneywell Y343B1002の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Honeywell Y343B1002に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Honeywell Y343B1002デバイスの基本機能を使うにあたってのヒント。 Honeywell Y343B1002のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Honeywell Y343B1002に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるHoneywell Y343B1002のメーカー/サービスへの連絡先に関する情報。

Honeywell Y343B1002についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもHoneywell Y343B1002の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがHoneywell Y343B1002で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)