Desa (V)CB36P(E)の取扱説明書

36ページ 2.69 mb
ダウンロード

ページに移動 of 36

Summary
  • Desa (V)CB36P(E) - page 1

    VENTED GAS FIREPLACE INST ALLA TION AND OWNER’S OPERA TION MANU AL 4" B-VENT DECORA TIVE GAS FIREPLACES MODELS (V)CB36N(E) AND (V)CB36P(E) W ARNING: If the information in this manual is not fol- lowed exactly , a re or explosion may result causing property damage, personal injury or loss of life. — Do not store or use gasoline or other ...

  • Desa (V)CB36P(E) - page 2

    www .desatech.com 1 17437-01B 2 W ARNING: Improper in - stallation, adjustment, alteration, service or maintenance can cause injury or property dam - age. Refer to this manual for correct installation and operational proce - dures. For assistance or additional information consult a qualified in - staller , service agency or the gas supplier . This ...

  • Desa (V)CB36P(E) - page 3

    www .desatech.com 1 17437-01B 3 Do not place clothing or other ammable material on or near the appliance. Never place any objects on or around replace. Firepl ace reaches high tempera - tures. Keep children and adults away from hot surface to avoid burns or clothing ignition. Fire - place will remain hot for a time after shutdown. Allow surfa ...

  • Desa (V)CB36P(E) - page 4

    www .desatech.com 1 17437-01B 4 4. Never install the replace • in a recreational vehicle • in windy or drafty areas where curtains or other combustible (ammable) objects can make contact with the replace front • in high trafc areas 5. Do not modi fy this rep lace und er any circu m - stance s. An y parts removed for servicing m ...

  • Desa (V)CB36P(E) - page 5

    www .desatech.com 1 17437-01B 5 PRODUCT FEA TURES These are a few facts that can help you understand and enjoy your vented decorative replace: • The (V)CB36N(E) and (V)CB36P(E) series of vented decorative replaces may be recessed into an exterior chase, an interior ush wall enclosure or a framed-in corner installation. • Models (V)CB36 ...

  • Desa (V)CB36P(E) - page 6

    www .desatech.com 1 17437-01B 6 • A hear th ext ensio n is n ot re quired with this appliance. If one is installed, it is for aesthetic purposes only and does not have to meet stan- dard requirements for hearth extensions. • If you pla n on inst all ing a telev isi on or enter tai n- ment cente r reces sed abo ve your repla ce, it is rec omm ...

  • Desa (V)CB36P(E) - page 7

    www .desatech.com 1 17437-01B 7 Figure 6 - Framing Clearances for Corner Installation 28 5 / 8 " (72.7 cm) 21" (53.3 cm) T o Center of T op Vent 14 3 / 4 " (37.5 cm) 14 3 / 4 " (37.5 cm) to Nailing Flanges 56 3 / 4 " (144 cm) 12 1 / 4 " (31 cm) to Opening PRE-INST ALLA TION PREP ARA TION Continued Figure 7 - Unit Dimen ...

  • Desa (V)CB36P(E) - page 8

    www .desatech.com 1 17437-01B 8 Figure 9 - Clearances for Combustible Mantels Figure 8 - Side Clearances for Combustible Mantels PRE-INST ALLA TION PREP ARA TION Continued 1 1 / 2 " (3.8 cm) 3 1 / 2 " (8.9 cm) Outer Surround Combustible Material May Be Used Perpendicular Side Wall 5 1 / 4 " (13.3 cm) 1 3 / 4 " (4.4 cm) T o Firep ...

  • Desa (V)CB36P(E) - page 9

    www .desatech.com 1 17437-01B 9 This appliance may be vented through a manu- factured chimney liner system if all are listed, inspected and approved by local codes and/or building authorities. The examples shown in Figure 10 are typical of most B-vent installations and code practices. W AR N IN G: Th is g as r ep la ce a n d v e n t as s e m b l ...

  • Desa (V)CB36P(E) - page 10

    www .desatech.com 1 17437-01B 10 Lowest Discharge Opening Listed V ent Cap 8 Ft. Min. Roof Pitch x/12 Listed Clearance 12 x Listed Gas V ent H (Min) Height From Roof Figure 1 1 - B-V ent Termination Roof Pitch H (Min.) Flat to 6/12 1.0 ft (0.3 m) 6/12 to 7/12 1.25 ft (0.38 m) Over 7/12 to 8/12 1.5 ft (0.46 m) Over 8/12 to 9/12 2.0 ft (0.61 m) Over ...

  • Desa (V)CB36P(E) - page 11

    www .desatech.com 1 17437-01B 1 1 Remote Receiver or Wall Switch to T erminal Marked “TH” Wire Harness From High Limit Switch Male Connector to Remote Receiver or Wall Switch 9. Strip back outer Romex to about 4" and con - nect black, white and green wires accordingly using 3 wire nut connectors. 10. Tu ck ta ili ng wire s int o jun ct io ...

  • Desa (V)CB36P(E) - page 12

    www .desatech.com 1 17437-01B 12 6. Use clips to mount receiver on remote mount - ing bracket as shown in Figure 16. INST ALLING OPTIONAL CONTROLS Continued 9-V olt Battery Battery Housing Battery Cover T erminal Wires Remote Control Unit T owards Front REMOTE ON OFF Figure 16 - Mounting Remote Receiver to Bracket Figure 17 - Installing Battery in ...

  • Desa (V)CB36P(E) - page 13

    www .desatech.com 1 17437-01B 13 Fi gu re 2 0 - Mi ll iv ol t Ig ni ti on W ir in g Di ag ra m Figure 21 - Electronic Ignition Wiring Diagram TH TP TH/TP WHITE RED DO NOT CONNECT TO 120V HIGH LIMIT SWITCH N O T O L P F F O I NC Pilot Burner Incoming Main Gas Supply Thermocouple W all Switch/Remote Receiver Replace factory wiring with 105° C equiva ...

  • Desa (V)CB36P(E) - page 14

    www .desatech.com 1 17437-01B 14 FI REP LA CE I N ST ALL A TI ON CHECK GAS TYPE Use only the correct type of gas (natural or pro - pane/LP). If your gas supply is not the correct gas type, do not install replace. See dealer where you purchased your replace for proper gas type replace or tro purchase gas conversion kit (see Accessories , pa ...

  • Desa (V)CB36P(E) - page 15

    www .desatech.com 1 17437-01B 15 FI REP LA CE I N ST ALL A TI ON Continued W e recommend that you install a sediment trap/ drip leg in supply line as shown in Figure 23. Lo- cate sediment trap/drip leg where it is within reach for cleaning. Install in piping system between fuel suppl y and replace. Locate sedimen t trap/d rip leg where trapped m ...

  • Desa (V)CB36P(E) - page 16

    www .desatech.com 1 17437-01B 16 T est Pressures Equal T o or Less Than 1/2 PSIG (3.5 kPa) 1. Cl os e eq ui pm en t sh ut of f v al ve ( se e Fi gur e 2 5). 2. Pr ess uri ze su pp ly pi pin g sys te m b y e it her opening propane/LP supply tank valve for propane/LP gas replace or opening main gas valve located on or near gas meter for natural ga ...

  • Desa (V)CB36P(E) - page 17

    www .desatech.com 1 17437-01B 17 Figure 28 - Removing Louver Panel Louver Panel Spring Latch Removing/Replacing Glass Door W A RN I N G: H a n dl e g la s s door panel with care. Do not strike, slam or otherwise abuse glass. Do not operate fire - place with glass door removed, cracked or broken. If replacement of glass is necessary , the entire ass ...

  • Desa (V)CB36P(E) - page 18

    www .desatech.com 1 17437-01B 18 INST ALLING LOGS AND GLOWING EMBERS A 4 piece ceramic log set comes packed inside the unit rebox. Removal of glass door is necessary to unpack and assemble logs and add hearth treat - ments. Follow steps under Removing/Replacing Glass Door , page 17 to access logs and burner . Assemble logs and add burner treatme ...

  • Desa (V)CB36P(E) - page 19

    www .desatech.com 1 17437-01B 19 O F F P I L O T O N OPERA TING FIREPLACE MANU AL IGNITION SY STEM FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not fol- low these instructions exactly , a re or explosion may result causing property damage, per - sonal injury or loss of life. A. This appliance has a pilot which must be lighted by hand ...

  • Desa (V)CB36P(E) - page 20

    www .desatech.com 1 17437-01B 20 OPERA TING FIREPLACE Continued MANUAL LIGHTING PROCEDURE 1. Rem ove gla ss doo r (se e Remov in g/Re pl aci ng Glass Door , page 17). 2. Follow steps 1 through 8 under Lighting Instructions , page 19). 3. Press gas control knob and light pilot with match. 4. K ee p ga s co nt r o l k n ob pr es se d i n fo r 30 se c ...

  • Desa (V)CB36P(E) - page 21

    www .desatech.com 1 17437-01B 21 OPERA TING FIREPLACE Continued O F F P I L O T L O I H ON OFF REMOTE ON OFF O N Blower Control Knob (Optional Accessory) V ariable Control Knob Selector Switch in Remote Position Gas Control Knob in ON Position Figure 36 - Setting the Selector Switch, Gas Control Knob and V ariable Control Knob for Remote Operation ...

  • Desa (V)CB36P(E) - page 22

    www .desatech.com 1 17437-01B 22 INSPECTING B URNERS Check pilot ame pattern and burner ame pat - terns often. PILOT ASSEMBL Y The pilot assembly is factory preset for the proper ame height. Alterations may have occurred dur - ing shipping and handling. Call a qualied service person to readjust the pilot if necessary . The position and ...

  • Desa (V)CB36P(E) - page 23

    www .desatech.com 1 17437-01B 23 CLEANING AND MAINTENANCE W ARNING: T urn off replace and let cool before cleaning. CAUTION: Y ou must keep control areas, burners, and cir - cu lat in g air pas sag es of re pla ce clean. Inspect the se areas of replace before each use. Have replace inspected yearly by a qualied service person. Fire - ...

  • Desa (V)CB36P(E) - page 24

    www .desatech.com 1 17437-01B 24 LOGS • If you remove logs for cleaning, refer to In- stalling Logs and Glowing Embers , page 18, to properly replace logs. • Use a vacuum cleaner to remove any carbon buildup on logs. • Replace log(s) if broken. See Replacement Parts, page 34. • Replace ember material periodically as needed. See Replacement ...

  • Desa (V)CB36P(E) - page 25

    www .desatech.com 1 17437-01B 25 TROUBLESHOO TING W ARNING: T urn off heater and let cool before servicing. Only a qualied service person should service and repair heater . CAUTION: Never use a wire, needle or similar object to clean ODS/pilot. This can damage ODS/pilot unit. Note: All troubleshooting items are listed in order of operation. The ...

  • Desa (V)CB36P(E) - page 26

    www .desatech.com 1 17437-01B 26 TROUBLESHOO TING Continued POSSIBLE CAUSE 1. Gas con trol kno b no t fu lly pressed in 2. Gas control knob not pressed in long enough 3. Equipment shutof f valve not fully open 4 . Pilot flame not touching ther moco uple , which allow s th er mo co up le to co ol , cau si ng pilo t to go ou t. Th is pro blem cou ld ...

  • Desa (V)CB36P(E) - page 27

    www .desatech.com 1 17437-01B 27 TROUBLESHOO TING Continued POSSIBLE CAUSE 1. T urning gas control knob to HI position when burner is cold 2. Air in gas line 3. Dirty or partially clogged burner orice 1. Flame impingement on logs 2 . Debris around burner air mixer 1. Metal expanding while heat- ing or contracting while cooling 1. Battery is not ...

  • Desa (V)CB36P(E) - page 28

    www .desatech.com 1 17437-01B 28 TROUBLESHOO TING Continued POSSIBLE CAUSE 1 . No gas supply , or shutoff valve is OFF 2. Air in gas line 3. Constr uction debris clogging pilot orice 4. Low gas pressure 5. Kinked pilot line 6. Cont rol valv e is not ope ning 7. No power to unit or the igni- tion module 1. Lo os e wir ing on ign it or wi re to ig ...

  • Desa (V)CB36P(E) - page 29

    www .desatech.com 1 17437-01B 29 TROUBLESHOO TING Continued W ARNING: If you smell gas • Shut off gas supply . • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor ’ s phone. Fol - low the gas supplier ’ s instructions. • ...

  • Desa (V)CB36P(E) - page 30

    www .desatech.com 1 17437-01B 30 ILL USTRA TED P ARTS BREAKDOWN FIREPLACE ASSEMBL Y FOR MODELS (V)CB36N, (V)CB36P , (V)CB36NE AND (V)CB36PE 12 14 1-2 1-1 1-4 1-3 20 8 1 1 10 5 6 7 18 9 13 26 27 17 21 22 25 26 3 24 4 16 23 2 15 26 19 ...

  • Desa (V)CB36P(E) - page 31

    www .desatech.com 1 17437-01B 31 P ARTS LIST This list contains replaceable parts used in your replace. When ordering parts, follow the instructions listed under Replacement Parts on page 34 of this manual. KEY NO. P ART NO. DESCRIPTION QTY . 1 1 16108-01 Log Set • • • • 1 1-1 1 16109-01 Burner Base Log • • • • 1 1-2 1 161 10-01 ...

  • Desa (V)CB36P(E) - page 32

    www .desatech.com 1 17437-01B 32 ILL USTRA TED P ARTS BREAKDOWN BURNER ASSEMBL Y FOR MODELS (V)CB36N (V)CB36P , (V)CB36NE AND (V)CB36PE H IG H V O L T A G E 3 4 5 6 7 8 9 1 21 20 24 28 25 26 29 27 30 31 22 15 23 2 Piezo Ignition Models Only Electric Ignition Models Only 19 18 12 13 14 15 16 17 10 1 1 ...

  • Desa (V)CB36P(E) - page 33

    www .desatech.com 1 17437-01B 33 P ARTS LIST This list contains replaceable parts used in your replace. When ordering parts, follow the instructions listed under Replacement Parts on page 34 of this manual. KEY NO. DESCRIPTION QTY . 1 1 16317-01 Remote Ignitor Bracket • • 1 2 14261 Ignitor Piezo • • 1 3 108085-01 Pilot Orice #51(Natur ...

  • Desa (V)CB36P(E) - page 34

    www .desatech.com 1 17437-01B 34 ACCESSORIES NOTE: All accessories may not be available for all replace models. Purchase these replace accessories from your local retailer . If they can not supply these acces- sories, call DESA ’ s Sales Department at 1-866- 672-6040, for information. Y ou can also write to the address listed on the back of ...

  • Desa (V)CB36P(E) - page 35

    www .desatech.com 1 17437-01B 35 RECEIVER AND HAND-HELD ON/OFF REMOTE CONTROL KIT HRC100 SERIES Allows the replace to be turned on and off con - veniently with dual safety lock feature. REMOTE CONTROL KIT - WRC SERIES Standard ON/OFF electronic remote control kit. W ALL MOUNTED ON/OFF SWITCH GWMS2 (Not Shown) Allows burner system to be turned on ...

  • Desa (V)CB36P(E) - page 36

    117437 01 2701 Industrial Drive P .O. Box 90004 Bowling Green, KY 42102-9004 www .desatech.com NOT A UPC WARRANTY INFORMA TION KEEP THIS WARRANTY Always specify model and serial numbers when communicating with the factory . W e reserve the right to amend these specications at any time without notice. The only warranty applicable is our standard ...

メーカー Desa カテゴリー Indoor Fireplace

Desa (V)CB36P(E)のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- (V)CB36P(E)の取扱説明書
- Desaの製品カード
- パンフレット
- またはDesa (V)CB36P(E)の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Desa (V)CB36P(E)の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Desa (V)CB36P(E)の取り付け説明書、サービスマニュアル、簡易説明書、またはDesa (V)CB36P(E)のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Desa (V)CB36P(E)の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Desa (V)CB36P(E)デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがDesa (V)CB36P(E)を使用するのを助ける技術的文書のことです。説明書は通常、全てのDesa (V)CB36P(E)ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Desaの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Desa (V)CB36P(E)の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははDesa (V)CB36P(E)の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Desa (V)CB36P(E)に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Desa (V)CB36P(E)デバイスの基本機能を使うにあたってのヒント。 Desa (V)CB36P(E)のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Desa (V)CB36P(E)に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるDesa (V)CB36P(E)のメーカー/サービスへの連絡先に関する情報。

Desa (V)CB36P(E)についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもDesa (V)CB36P(E)の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがDesa (V)CB36P(E)で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)