  • Universal Security Instruments 3304L - page 1

    READ ALL INSTRUCTIONS SMOKE & FIRE ALARM WITH SILENCE FEA TURE AND ALARM ORIGINA TION FEA TURE T able of Contents: Page # Smoke Alarm Limitations and Functions ................................. 2 Recommended Location of Alarms ......................................... 3 Avoid These Locat ions .................................................... ...

  • Universal Security Instruments 3304L - page 2

    Page 2 SMOKE ALARM LIMIT A TIONS AND FUNCTIONS  There are three basic smoke alarm types: IoPhic , Ionization and Photoelectric . IoPhic is an ionization alarm containing a patent-pending Universal Smoke Sensing T echnology . IoPhic alarms are very effective at detecting fast flaming fires and also respond very quickly to slow smoldering fires - ...

  • Universal Security Instruments 3304L - page 3

    RECOMMENDED LOCA TION OF ALARMS • Locate the first smoke alarm in the immediate area of the bedrooms. T ry to protect the escape route as the bedrooms are usually farthest from an exit. If more than one sleeping area exists, locate additional smoke alarms in each sleeping area. If a hall is more than 40 feet (12 meters) long, install a smoke alar ...

  • Universal Security Instruments 3304L - page 4

    THIS SMOKE ALARM WILL NOT WORK WITHOUT 120 V AC POWER AND A GOOD BA TTERY PROPERL Y INST ALLED. THE SMOKE ALARM SHOULD BE TESTED WHEN INST ALLED AND THEN TESTED WEEKL Y AFTER THA T . INST ALLA TION INSTRUCTIONS: CAUTION!! READ CAREFULL Y . Installation of this alarm must conform to the electrical codes in your area; Article 760 of the National Elec ...

  • Universal Security Instruments 3304L - page 5

    DO NOT T AMPER WITH WIRES WHEN POWER IS ON! For alarms that are used as single smoke alarms, do not connect the yellow wire to anything. Insulate this wire (tape it) in place to make certain the yellow wire cannot contact any metal parts. Interconnected alarms can provide earlier warning of fire than stand-alone alarms, especially if a fire starts ...

  • Universal Security Instruments 3304L - page 6

    The yellow wire is used only for multiple station operation with USI ELECTRIC or UNIVERSAL Model alarms only . Connecting this yellow wire to any other circuits may result in damage and smoke alarm malfunction. When alarms are interconnected, all smoke alarms must be powered from a single AC branch circuit. If local codes do not permit, be sure the ...

  • Universal Security Instruments 3304L - page 7

    b. Interconnected alarms will sound and then stop. c. The originating smoke alarm will continue to sound 60 seconds to allow ample time to quickly find originating alarm. RESET : T o reset the QUICK FIND ® Alarm Origination condition, press and hold the T est button on any alarm for at least 10 seconds and then release. Reset after each alarm. The ...

  • Universal Security Instruments 3304L - page 8

    Page 8 OPTIONAL BA TTERY DRA WER T AMPER LOCKING PIN: T o make your battery drawer tamper resistant, a locking pin has been provided (breakaway part on mounting bracket). NOTE: If this feature has been activated, you will need to deactivate it by removing the battery drawer tamper pin located at side of battery drawer . Refer to Page 5. Pull the QU ...

  • Universal Security Instruments 3304L - page 9

    Page 9 THIS PRODUCT IS LISTED TO UL ST ANDARD FOR SAFETY , UL217 BY UNDERWRITERS LABORA T ORIES, INC. Blinks On once approx every 40-45 seconds S tays On AC Power is present. DC Power is present. Blinks On once approx every 40-45 seconds Off AC Power is not present and alarm is receiving DC Power. Check the breaker or fuse box for power . If the br ...

  • Universal Security Instruments 3304L - page 10

    ©2010 UNIVERSAL SECURITY I NSTRUMENTS, INC. Printed in China 288-3452-00 Visit Us on the W eb! w w w .UsiElectric.com 1 1407 Cronhill Drive, Suite A Owings Mills, Maryland 21 1 17 USA FIVE YEAR LIMITED WARRANTY MODELS 3304, 3304L MODELS 3895, 3895L USI ELECTRIC, INC./UNIVERSAL SECURITY INSTRUMENTS, INC. ("USI") warrants your USI product ...

メーカー Universal Security Instruments カテゴリー Smoke Alarm

Universal Security Instruments 3304Lのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 3304Lの取扱説明書
- Universal Security Instrumentsの製品カード
- パンフレット
- またはUniversal Security Instruments 3304Lの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Universal Security Instruments 3304Lの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Universal Security Instruments 3304Lの取り付け説明書、サービスマニュアル、簡易説明書、またはUniversal Security Instruments 3304Lのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Universal Security Instruments 3304Lの製品を使用するにあたって最も人気のある説明書を閲覧できます。

Universal Security Instruments 3304Lデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがUniversal Security Instruments 3304Lを使用するのを助ける技術的文書のことです。説明書は通常、全てのUniversal Security Instruments 3304Lユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Universal Security Instrumentsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Universal Security Instruments 3304Lの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははUniversal Security Instruments 3304Lの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Universal Security Instruments 3304Lに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Universal Security Instruments 3304Lデバイスの基本機能を使うにあたってのヒント。 Universal Security Instruments 3304Lのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Universal Security Instruments 3304Lに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるUniversal Security Instruments 3304Lのメーカー/サービスへの連絡先に関する情報。

Universal Security Instruments 3304Lについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもUniversal Security Instruments 3304Lの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがUniversal Security Instruments 3304Lで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)