    Owner's Manual GP 3250 P or table Generator MODEL: 005982-0 ...

  • Generac 005982-0 - page 2

    Owner's Manual Introduction ....................................................................................... 1 Read this Manual Thoroughly ........................................................... 1 Safety Rules ..................................................................................... 2 Standards Index .................... ...

  • Generac 005982-0 - page 3

    INTRODUCTION Thank you for purchasing this model by Generac P ower Systems, Inc. This model is a compact, high per formance, air-cooled, engine driven generator designed to supply electrical power to operate electrical loads where no utility power is available or in place of utility due to a power outage. READ THIS MANUAL THOROUGHL Y If any por tio ...

  • Generac 005982-0 - page 4

    Do not inser t objects through unit’s cooling slots. • When working on this equipment, remain aler t at all times. • Never work on the equipment when physically or mentally fatigued. Never use the generator or any of its par ts as a step. Stepping • on the unit can stress and break par ts, and may result in dangerous operating conditions fr ...

  • Generac 005982-0 - page 5

    ST ANDARDS INDEX In the absence of per tinent standards, codes, regulations and laws, the published information listed below may be used as a guideline for operation of this equipment. Always reference the latest revision available for the standards listed. 1. NFP A No. 70, NFP A HANDBOOK OF NA TIONAL ELECTRIC CODE. 2. Ar ticle X, NA TIONAL BUILDIN ...

  • Generac 005982-0 - page 6

    4 1.1 UNP ACKING Remove all packaging material. • Remove separate accessory box. • Remove the generator from car ton. • 1.1.1 ACCESSOR Y BOX Check all contents. If any par ts are missing or damaged, locate an authorized dealer at 1-888-436-3722. 1 - Owner ’s manual • 1 - Oil SAE 30 • 3 - Product R egistration Cards (English, Spanish, Fr ...

  • Generac 005982-0 - page 7

    5 Figure 3 - Control P anel 9. Muffler – Quiets the engine. 10. Handle – Pivot and retract for storage. 11. Gas Cap – Fuel fill location. 12. Fuel Gauge – Shows fuel level in tank. 13. Oil Check/Fill – Check and fill oil here. 14. Recoil Star ter – Use to star t engine manually . 15. Fuel Shut Off – V alve between fuel tank and carbur ...

  • Generac 005982-0 - page 8

    6 2.2 CORD SETS AND CONNECTION PL UGS 2.2.1 120 VAC DUPLEX RECEPT ACLE This is a 120 V olt outlet protected against overload by a 14 Amp circuit breaker (Figure 7). 14 Amps of current may be drawn from each socket, however , total power drawn must be kept within data plate ratings. Use only high quality , well insulated, 3-wire grounded cord sets r ...

  • Generac 005982-0 - page 9

    7 2.3.2 CONNECTING ELECTRICAL L OADS DO NOT connect 240 V olt loads to 120 V olt receptacles. DO NOT connect 3-phase loads to the generator . DO NOT connect 50 Hz loads to the generator . Let engine stabilize and warm up for a few minutes af ter star ting. • Plug in and turn on the desired 120 or 240 Volt AC, single phase, 60 • Hz electrical lo ...

  • Generac 005982-0 - page 10

    8 2.6 BEFORE ST ARTING THE GENERA TOR Prior to operating the generator , engine oil and gasoline will need to be added, as follows: 2.6.1 ADDING ENGINE OIL All oil should meet minimum American P etroleum Institute (API) Ser vice Class SJ, SL or better . Use no special additives. Select the oil's viscosity grade according to the expected operat ...

  • Generac 005982-0 - page 11

    9 T urn engine ON/OFF switch to • ON position (Figure 11). Move engine CHOKE lever to the • FULL CHOKE position (Figure 11). T o star t engine, fir mly grasp the recoil handle and pull slowly • until increased resistance is felt. Pull rapidly up and away . When engine star ts, move choke lever to • 1/2-CHOKE position until engine r uns smoo ...

  • Generac 005982-0 - page 12

    10 3.3 GENERAL RECOMMENDA TIONS The warranty of the generator does not cover items that have been subjected to operator abuse or negligence. T o receive full value from the warranty , the operator must maintain the generator as instr ucted in this manual. Some adjustments will need to be made periodically to properly maintain the generator . All ad ...

  • Generac 005982-0 - page 13

    11 3.3.6 REPL ACING THE SP ARK PLUG Use spark plug F6TC, NGK BP6IS or Champioin RN11YC. Replace the plug once each year . This will help the engine star t easier and r un better . 1. Stop the engine and pull the spark plug wire off of the spark plug. 2. Clean the area around the spark plug and remove it from the cylinder head. 3. Set the spark plug ...

  • Generac 005982-0 - page 14

    12 3.7 L ONG TERM STORAGE It is impor tant to prevent gum deposits from for ming in essential fuel system par ts such as the carburetor , fuel hose or tank during storage. Also, experience indicates that alcohol-blended fuels (called gasohol, ethanol or methanol) can attract moisture, which leads to separation and formation of acids during storage. ...

  • Generac 005982-0 - page 15

    13 4.1 TROUBLESHOOTING GUIDE PROBLEM CAUSE CORRECTION Engine is running, but no AC output is available. 1. Circuit breaker is open. 2. P oor connection or defective cord set. 3. Connected device is bad. 4. Fault in generator . 1. Reset circuit breaker . 2. Check and repair . 3. Connect another device that is in good condition. 4. Contact Authorized ...

  • Generac 005982-0 - page 16

    14 Notes ...

  • Generac 005982-0 - page 17

    15 Notes ...

  • Generac 005982-0 - page 18

    16 FEDERAL EMISSION CONTROL WARRANTY ST A TEMENT YOUR W ARRANTY RIGHTS AND OBLIGA TIONS The United States Environmental Protection Agency (EP A) and Generac Power Systems, Inc. (Generac) are pleased to explain the Emission Control System warranty on your new 2008 and later equipment. New equipment that use small spark -ignited engines must be desig ...

  • Generac 005982-0 - page 19

    17 EMISSION CONTROL SYSTEM WARRANTY Emission Control System Warranty (ECS warranty) for equipment using small spark -ignited engines: (a) Applicability: This warranty shall apply to equipment that uses small off-road engines. The ECS Warranty period shall begin on the date the new equipment is purchased by/delivered to its original, end-use purchas ...

  • Generac 005982-0 - page 20

    Manual P ar t No. 0H9247 Rev B (10/06/10) Printed in China W arranty GENERAC POWER SYSTEMS “TWO YEAR” LIMITED WARRANTY FOR GP SERIES PORT ABLE GENERA TORS For a period of two years from the date of original sale, Generac P ower Systems, Inc. (Generac) warrants its GP Series generators will be free from defects in materials and workmanship for t ...

メーカー Generac カテゴリー Portable Generator

Generac 005982-0のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 005982-0の取扱説明書
- Generacの製品カード
- パンフレット
- またはGenerac 005982-0の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Generac 005982-0の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Generac 005982-0の取り付け説明書、サービスマニュアル、簡易説明書、またはGenerac 005982-0のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Generac 005982-0の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Generac 005982-0デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがGenerac 005982-0を使用するのを助ける技術的文書のことです。説明書は通常、全てのGenerac 005982-0ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Generacの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Generac 005982-0の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははGenerac 005982-0の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Generac 005982-0に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Generac 005982-0デバイスの基本機能を使うにあたってのヒント。 Generac 005982-0のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Generac 005982-0に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるGenerac 005982-0のメーカー/サービスへの連絡先に関する情報。

Generac 005982-0についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもGenerac 005982-0の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがGenerac 005982-0で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)