Furuno FCV-600Lの取扱説明書

34ページ 0.61 mb
ダウンロード

ページに移動 of 34

Summary
  • Furuno FCV-600L - page 1

    ...

  • Furuno FCV-600L - page 2

    C 9 - 52, Ashihara - cho, Nishinomiya, Japan Telephone: 0798 - 65 - 2111 Telefax: 0798 - 65 - 4200 Your Local Agent/Dealer All rights reserved. PUB. No. O ME - 23 62 0 FCV - 600 L ( DAMI ) FIRST EDITION : APR . 199 8 H 3 : OCT. 7 , 200 2 Printed in Japan ...

  • Furuno FCV-600L - page 3

    i i i i i i i i i i i i i i SAFETY INSTRUCTIONS WARNING Keep heater away from equipment. A heater can melt the equipment’s power cord, which can cause fire or electrical shock. Use the proper fuse. Use only a 3A fuse. Use of a wrong fuse can result in equipment damage and void the warranty. The TFT LCD is constructed using the latest LCD techniqu ...

  • Furuno FCV-600L - page 4

    ii FOREWORD ....................................... iii MENU TREE ....................................... iv SYSTEM CONFIGURA TION ....... v PRINCIPLE OF OPERA TION .... vi OPERA TIONAL OVER VIEW 1.1 Control Description ............................... 1 1.2 Indications, Markers .............................. 2 1.3 T urning On/Of f the Power ....... ...

  • Furuno FCV-600L - page 5

    iii A W ord to FCV -600L Owners Congratulations on your choice of the FURUNO FCV -600L Color LCD Sounder . W e are confident you will see why the FURUNO name has become synonymous with quality and reliability . For over 50 years FURUNO Electric Com- pany has enjoyed an enviable reputation for innovative and dependable marine electron- ics equipment ...

  • Furuno FCV-600L - page 6

    iv MENU TREE MENU ESC NOISE LIMITER ( OFF , NL1, NL2, NL3) CLUTTER (0~16) Default: 9 MARKER ( VRM ,WHITE MARKER) HUE (1~9) Default:1 GAIN ADJ 200kHz (-20~+20) Default: 0 GAIN ADJ 50kHz (-20~+20) Default: 0 GO T O SYSTEM MENU ( s ) SELF TEST ( t ) USER MENU MENU ( 1 , 2, 3) DEPTH UNIT (m, ft , fa, pb) SPEED UNIT ( kt , MPH, km/h) TEMP UNIT ( ° C, ? ...

  • Furuno FCV-600L - page 7

    v SYSTEM CONFIGURA TION Ship's mains 12-24 VDC External equipment (GPS navigator, etc.) TRANSDUCER Speed, temperature sensor (option) DISPLAY UNIT FCV -600L system configuration ...

  • Furuno FCV-600L - page 8

    vi The FCV -600L determines the distance be- tween its transducer and underwater objects such as fish, lake bottom or seabed and dis- plays the results on its screen. It does this by utilizing the fact that an ultrasonic wave trans- mitted through water travels at a nearly con- stant speed of 4800 feet (1500 meters) per second. When a sound wave st ...

  • Furuno FCV-600L - page 9

    1 OPERA TIONAL OVER VIEW 1.1 Control Description All operations of the FCV -600L are carried out with the controls on the front panel of the display unit. All controls respond immediately to your command and the unit emits a beep to signify correct key sequence. (Invalid key input emits several beeps.) MENU ESC SHIFT - SHIFT + RANGE - RANGE + GAIN ...

  • Furuno FCV-600L - page 10

    2 1.2 Indications, Markers The figure below shows all indications and markers which may appear in the normal display . The combination displays (normal display plus marker or zoom display) may additionally dis- play the zoom marker . W ater temperature* Speed* Noise Limiter T r ansducer frequency Alar m icon Activ e alar m Range scale V ariable ran ...

  • Furuno FCV-600L - page 11

    3 1.3 T urning On/Off the Power Press the POWER key to turn the power on/ off. When the unit is turned on it proceeds in the sequence shown below . Sounder display ROM and RAM check; displayed for several seconds. ** Program version no. ROM: OK RAM: OK PROGRAM No: 02522800** 200k 0 20 40 60 80 49.6 0.0 Y ou may press any key to show the sounder dis ...

  • Furuno FCV-600L - page 12

    4 50k 49.6 0.0 Fish school Bottom 0 20 40 60 80 Figur e 1-7 T ypical 50 kHz normal display 200 kHz The higher the frequency of the ultrasonic pulse the better the resolution. Therefore, the 200 kHz frequency is ideal for detailed ob- servation of fish schools. Dual-frequency display The 50 kHz picture appears on the left; the 200 kHz picture on the ...

  • Furuno FCV-600L - page 13

    5 Bottom-zoom display This mode expands bottom and bottom fish echoes two to five times to vertical size of the screen, and is useful for determining bottom hardness. A bottom displayed with a short echo tail usually means it is a soft, sandy bot- tom. A long echo tail means a hard bottom. 0 10 20 30 40 15 20 25 36.4 Normal displa y Zoom marker (ye ...

  • Furuno FCV-600L - page 14

    6 Enlarging a nav data indication Y ou can enlarge and display one of the data indications as follows: 1. Press ▲ or ▼ to select the indication you want to display . A blue cursor circum- scribes your selection. For example, se- lect the waypoint data window . 2. Press s to enlarge the data. 0 20 40 60 80 WP ABC RNG 12.0 nm BRG 123. 4 ° XTE 1. ...

  • Furuno FCV-600L - page 15

    7 1.6 Selecting Display Range The basic range and range shifting functions used together give you the means to select the depth you can see on the screen. The basic range can be thought of as providing a “win- dow” into the water column and range shift- ing as moving the “window” to the desired depth. Display Shift Figur e 1-15 Range and di ...

  • Furuno FCV-600L - page 16

    8 1.8 Automatic Operation Automatic operation is useful when you are preoccupied with other tasks and do not have time to adjust the display . How it works The automatic function automatically selects the proper gain and range scale according to depth. It works as follows: • The range changes automatically to locate the bottom on the lower half o ...

  • Furuno FCV-600L - page 17

    9 1.10 Erasing Weak Echoes Dirty water or reflections from plankton may be painted on the display in green or light- blue. These weak echoes may be erased as follows: 1. Press the SIG LEV key . The following display appears. SIGNAL LEVEL OFF SL1 SL2 SL3 SL4 SL5 SL6 ▲ ▼ SIGNAL LEVEL OFF SL1 SL2 SL3 ▲ ▼ (At 16-color display) (At 8-color displ ...

  • Furuno FCV-600L - page 18

    10 1.12 A-scope Display This display shows echoes at each transmis- sion with amplitudes and tone proportional to their intensities, on the right 1/3 of the screen. It is useful for estimating the kind of fish school and bottom composition. 32.3 10 20 30 40 A-scope displa y Normal displa y 200k 0.0 0 Figur e 1-25 A-scope display 1. Press the A-SCOP ...

  • Furuno FCV-600L - page 19

    11 1.14 Suppressing Interference Interference from other acoustic equipment operating nearby or other electronic equip- ment on your boat may show itself on the dis- play as shown in Figure 1-28. T o suppress interference, do the following: 1. Press the MENU ESC key to display the User menu. 2. Select NOISE LIMITER. 3. Press t or s to select degree ...

  • Furuno FCV-600L - page 20

    12 1.17 Alarms Bottom alarm The bottom alarm sounds when the bottom is within the alarm range set. T o activate the bottom alarm the depth must be displayed. Fish alarm There are two types of fish alarms: bottom- lock and normal. The bottom-lock fish alarm sounds when fish are within a certain distance from the bottom. The normal fish alarm sounds ...

  • Furuno FCV-600L - page 21

    13 1.18 White Marker The white marker functions to display a par - ticular echo color in white. For example, you may want to display the bottom echo (red- dish-brown) in white to discriminate fish ech- oes near the bottom. Note that the bottom must be displayed in reddish-brown for the white marker to function. 1. Press the MENU ESC Key . 2. Press ...

  • Furuno FCV-600L - page 22

    This page is intentionally left blank . ...

  • Furuno FCV-600L - page 23

    15 2.1 Displaying the Optional Mode Menu The Optional mode mainly contains less-of- ten used functions which once preset do not require frequent adjustment. Y ou can access the Optional mode menu as follows: 1. Turn off the equipment. 2. Press the POWER key while pressing any key . The following display appears. t : SELF TEST s : CLEAR MEMORY t : D ...

  • Furuno FCV-600L - page 24

    16 System menu 1 description MENU: Selects system menu desired. DEPTH UNIT : Selects unit of depth mea- surement among meters, feet, fathoms, or passi/braza. Default setting is feet. SPEED UNIT : Selects unit of speed measure- ment among knots, miles per hour , or kilo- meters per hour . Default setting is knots. Requires speed data. TEMP UNIT : Se ...

  • Furuno FCV-600L - page 25

    17 Note 2: Ranges must be set in numerical order . For example, if basic range 3 is 60 feet and basic range 5 is 200 feet, the basic range which can be set for basic range 4 is between 60 and 200 feet. ZOOM RANGE: Select the range to zoom in the marker and bottom zoom modes. Y ou may select a range between 7 and 1500 feet. Default setting is 30 fee ...

  • Furuno FCV-600L - page 26

    18 2.5 TVG Level TVG (T ime V aried Gain) compensates for propagation attenuation of the ultrasonic waves. It does this by equalizing echo pre- sentation so that fish schools of the same size appear in the same density in both shallow and deep waters. In addition, it reduces sur - face noise. Note that if the TVG level is set too high short range e ...

  • Furuno FCV-600L - page 27

    19 3.1 Zero Line The zero line (sometimes referred to as the transmission line) represents the transducer’ s position, and moves of f the screen when a deep phased range is used. Zero line Shift Figur e 3-1 Zer o line 3.2 Fish School Echoes Fish school echoes will generally be plotted between the zero line and the bottom. Usu- ally the fish schoo ...

  • Furuno FCV-600L - page 28

    20 3.4 Surface Noise/Aeration When the waters are rough or the boat passes over a wake, surface noise may appear near the zero line. As surface turbulence is acous- tically equivalent to running into a brick wall, the bottom echo will be displayed intermit- tently . Similar noise sometimes appears when a water temperature dif ference (thermocline) ...

  • Furuno FCV-600L - page 29

    21 MAINTENANCE & TROUBLESHOOTING Do not open the cover. There are no user-serviceable parts inside. Refer any repair work to a qualified technician. WARNING WARNING 4.1 Checking Regular maintenance is essential for good per - formance. Checking the items listed in the table below on a regular basis will keep the equipment in good shape for year ...

  • Furuno FCV-600L - page 30

    22 4.5 T roubleshooting The table below provides simple troubleshooting procedures which you may follow to restore normal operation. If you cannot restore normal operation, contact your dealer . T able 4-2 T roubleshooting . . . f I. . . k c e h c n e h T e l a c s e g n a r d e x i f r o n o h c e r e h t i e n s r a e p p a . e g a t l o v y r e ...

  • Furuno FCV-600L - page 31

    23 4.6 T est The test checks the ROM, RAM, color bar and keyboard for proper operation. Y ou may start the test as follows: 1. Turn on the power while pressing any key . 2. Press t . The following display appears: PROGRAM No. 02522800** ** = V ersion no. ROM: RAM: Figur e 4-1 T est display 3. The ROM and RAM are checked and the results are displaye ...

  • Furuno FCV-600L - page 32

    24 4.8 Clearing the Memory The memory (all menu settings) can be cleared to start afresh. All default menu settings are restored when the memory is cleared. For your reference all default settings are shown in the menu tree at the beginning of this manual. 1. Turn on the power while pressing any key . 2. Press ▲ . The following display appears: s ...

  • Furuno FCV-600L - page 33

    SP - 1 SPECIFI CA TIONS O F COLOR L CD SOUNDER FCV -600L This e quipm e nt is a d ua l -freq ue ncy (50/200 k Hz) co lo r LCD v id eo soun de r wh ich h as a large var i ety o f fu nct ions, a ll cont a ined in a sp las h-p r oof r u gged pla st ic c a se tha t is com p a ct to f it s mall b oa ts . 1. GENERA L (1) T X Freq ue ncy 50 kH z/200 kHz ( ...

  • Furuno FCV-600L - page 34

    SP - 2 3. I/O D ATA (1) Data F o r m a t NMEA 0183(Ve r .1.5/2. 0) (2) Input Da ta RM A , RMB,BWC, GLL,VTG, V HW, MT W (3) Output Data SDDBT ,YCMT W,VWV HW 4. POW ER SUPP LY AND PO W E R CONSUMPTION (1) Vo ltage a n d Curr e nt 12-24 V DC: 1-0.5 A (2 ) P ower Cons u m p t ion 1 5 W or less 5. E NVIRONM E NTAL CO NDI TION (1) T em p e r atu re -15 ? ...

メーカー Furuno カテゴリー Flat Panel Television

Furuno FCV-600Lのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- FCV-600Lの取扱説明書
- Furunoの製品カード
- パンフレット
- またはFuruno FCV-600Lの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Furuno FCV-600Lの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Furuno FCV-600Lの取り付け説明書、サービスマニュアル、簡易説明書、またはFuruno FCV-600Lのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Furuno FCV-600Lの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Furuno FCV-600Lデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがFuruno FCV-600Lを使用するのを助ける技術的文書のことです。説明書は通常、全てのFuruno FCV-600Lユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Furunoの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Furuno FCV-600Lの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははFuruno FCV-600Lの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Furuno FCV-600Lに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Furuno FCV-600Lデバイスの基本機能を使うにあたってのヒント。 Furuno FCV-600Lのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Furuno FCV-600Lに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるFuruno FCV-600Lのメーカー/サービスへの連絡先に関する情報。

Furuno FCV-600Lについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもFuruno FCV-600Lの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがFuruno FCV-600Lで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください