Extron electronic MPA 401-70Vの取扱説明書

24ページ 2.54 mb
ダウンロード

ページに移動 of 24

Summary
  • Extron electronic MPA 401-70V - page 1

    68-1436-01 Rev. C 12 10 MPA 401 Series User Guide Audio Mini Power Amplifiers ...

  • Extron electronic MPA 401-70V - page 2

    This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product enclosure that may present a risk of electric shock. Caution Read Instructions • Read ...

  • Extron electronic MPA 401-70V - page 3

    FCC Class B Notice This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to pr ovide reasonable protection against harmful interfer ence in a resi- dential installation. This equipment generates, uses and can radiate radio frequency energy and ...

  • Extron electronic MPA 401-70V - page 4

    ...

  • Extron electronic MPA 401-70V - page 5

    Contents Introduction ............................................ 1 MP A 401-70V and MP A 401-100V Description 1 MP A 401-70V and MP A 401-100V Features ..... 2 Rear Panel and Cabling .......................... 3 Rear Panel Cabling ........................................... 3 Power Input ..................................................... 4 Aud ...

  • Extron electronic MPA 401-70V - page 6

    MP A 401-70V and MP A 401-100V • Contents vi ...

  • Extron electronic MPA 401-70V - page 7

    Intr oduction This guide contains information about the Extron MP A 401-70V and MP A 401-100V mini power amplifiers with instructions for experienced installers on how to install, configure, and operate the equipment. Unless otherwise specified, refer ences in this guide to the “amplifier ,” “MP A,” or “MP A 401” relate to the featu ...

  • Extron electronic MPA 401-70V - page 8

    MP A 401-70V and MP A 401-100V Features Patented CDRS (Class D Ripple Suppression) — CDRS is an Extr on patented technology that eliminates high frequency switching ripple and EMI emissions found in all Class D amplifiers. CDRS dramatically improves audio performance over conventional Class D amplifier designs and enables Extron power amplifie ...

  • Extron electronic MPA 401-70V - page 9

    Rear Panel and Cabling This section describes the rear panel featur es and cabling of the MP A 401-70V and MP A 401-100V . z Rear Panel Cabling z Power Input z Audio Inputs z Remote Input Connector z Speaker Connections Rear Panel Cabling The illustration below shows the rear panel of the amplifiers: POWER 12V 1.5A MAX OUTPUT 70V INPUTS L (MONO) ( ...

  • Extron electronic MPA 401-70V - page 10

    Power Input a Power connector — The MP A 401-100V ships with an Extron 36 W desktop power supply (PS 1230 [part number 70-769-01 ]). The MP A 401-70V ships with either the Extron 36 W desktop power supply or the Extr on 12 VDC, 5 A power supply (EPS 1250 C [part number 70-725-01 ]). When using the EPS 1250 C power supply , connect the two pole, 3 ...

  • Extron electronic MPA 401-70V - page 11

    When using the PS 1230 power supply with either amplifier , connect one end of the DC power cord to one of the two pole, 3.5 mm captive scr ew connectors on the power supply . Connect the other end into the power socket on the rear panel of the amplifier , as shown in figure 4 below . The power cord connectors ar e already corr ectly wired when ...

  • Extron electronic MPA 401-70V - page 12

    Remote Input Connector e Remote input connector (see gure 2) — This 3-pole captive scr ew connector allows the option of using a wall-mounted audio controller or MediaLink pr oduct to control volume and mute levels r emotely . Options for remote contr ol include the Extron VC 50, VCM 100 AAP , VCM 100 MAAP , or MLA VC10. Third party 10k potent ...

  • Extron electronic MPA 401-70V - page 13

    Setup and Operation This section provides information about the fr ont panel features and operation of the MP A 401-70V and MP A 401-100V : z Front Panel Featur es z Setting Input Level z Setting Bass and T reble z Remote Control Options Fr ont Panel Features The front panels of the MP A 401-70V and MP A 401-100V are identical and shown below: BASS ...

  • Extron electronic MPA 401-70V - page 14

    Setting Input Level Adjust the input level as follows: 1. If necessary , unplug the remote plug from the unit. 2. If connecting the amplifier to a system with adjustable volume, set the volume to its lowest point. Then adjust the level potentiometer fully counterclockwise to its minimum setting. 3. Set the system volume to its maximum level. No so ...

  • Extron electronic MPA 401-70V - page 15

    Remote Contr ol Options INPUTS OUTP UT 50/60 Hz 100-240V .3A 2 1 3 4 L R L R L R L R L R AUDIO VID 1 2 3 4 Y /VID B-Y H/ HV R /R-Y V G /Y B /B-Y RS-232 LAN RESET ACT LINK DVI-I YC SDI R-Y /C RGB/R-Y ,Y,B-Y/YC/VI D I N P U T O U T P U T I N P U T O U T P U T POWER 12V 1.5A MAX OUTPUT 70V INPUTS L (MONO) (MONO) R REMOTE VOL/MUTE MPA 401-70V R L CLASS ...

  • Extron electronic MPA 401-70V - page 16

    Specications Audio V oltage gain MP A 401-70V RCA and TRS inputs ........... 222x (47 dB) Captive screw input ........... 57x (35 dB) MP A 401-100V RCA and TRS inputs ........... 317x (50 dB) Captive screw input ........... 81x (38 dB) CMRR ............................................ 75 dB (typical) @ 1 kHz Bass adjustment ..................... ...

  • Extron electronic MPA 401-70V - page 17

    Output power MP A 401-70V .......................... 40 watts (rms), 70 V , 1 kHz, 1% THD MP A 401-100V ........................ 40 watts (rms), 100 V , 1 kHz, 1% THD Control/r emote — amplier Control port ................................... (1) 3.5 mm captive screw connector , 3 pole Pin configuration ............................ Pin 1 = +10 ...

  • Extron electronic MPA 401-70V - page 18

    Parts and Accessories This section of the user guide contains information about: z Included Parts z Optional Accessories Included Parts Description Part Number MP A 401-70V or MP A 401-100V 60-845-01 60-845-11 EPS 1250 C External 12 VDC, 5 A power supply (MP A 401-70V) or PS 1230 External 36 W power supply (MP A 401-70V and MP A 401-100V) 70-725-01 ...

  • Extron electronic MPA 401-70V - page 19

    Optional Accessories Description Part Number RSU 126 1U, 6 inch deep, universal rack kit 60-190-10 RSB 126 1U, 6 inch deep basic rack shelf 60-604-11 RSU 129 1U, 9.5 inch deep, universal rack kit 60-190-01 RSB 129 1U, 9.5 inch deep basic rack shelf 60-604-02 MBU 125 Under -desk mounting kit 70-077-01 MBD 129 Through-desk mounting kit 70-077-02 PMK ...

  • Extron electronic MPA 401-70V - page 20

    Mounting This section outlines the various mounting options available for the MP A 401 series amplifiers: z Plenum Placement z T abletop Placement z Rack Mounting z Under -desk Mounting z Through-desk Mounting z Projector Mounting Plenum Placement The MP A 401-70V and MP A 401-100V amplifiers meets UL 2043 requir ements for heat and smoke release ...

  • Extron electronic MPA 401-70V - page 21

    Rack Mounting UL Guidelines For Rack Mounting The following Underwriters Laboratories (UL) guidelines are r elevant to the safe installation of these products in a rack: 1. Elevated operating ambient temperature — If the unit is installed in a closed or multi-unit rack assembly , the operating ambient temperature of the rack envir onment may be g ...

  • Extron electronic MPA 401-70V - page 22

    Rack Mounting Procedur e The unit can be mounted on any of these optional Extron rack systems: z RSU 126: 6 inch deep, 1U rack shelf kit (part number 60-190-10 ) z RSB 126: 6 inch deep, 1U basic rack shelf (part number 60-604-11 ) z RSU 129: 9.5 inch deep, 1U rack shelf kit (part number 60-190-01 ) z RSB 129: 9.5 inch deep, 1U basic rack shelf (par ...

  • Extron electronic MPA 401-70V - page 23

    Extr on ® W arranty Extron Electr onics warrants this product against defects in materials and workmanship for a period of three years fr om the date of purchase; touchscreen display and overlay components ar e covered for 1 year . In the event of malfunction during the warranty period attributable directly to faulty workmanship and/or materials, ...

  • Extron electronic MPA 401-70V - page 24

    Extron USA - W est Headquarters + 800.633.9876 Inside USA/Canada Only +1.714.491.1500 +1.714.491.1517 FA X Extron USA - East +800.633.9876 Inside USA/Canada Only +1.919.863.1794 +1.919.863.1797 FA X Extron Eur ope +800.3987.6673 Inside Europe Only +31.33.453.4040 +31.33.453.4050 FA X Extron Asia +800.7339.8766 Inside Asia Only +65.6383.4400 +65.638 ...

メーカー Extron electronic カテゴリー Car Amplifier

Extron electronic MPA 401-70Vのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- MPA 401-70Vの取扱説明書
- Extron electronicの製品カード
- パンフレット
- またはExtron electronic MPA 401-70Vの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Extron electronic MPA 401-70Vの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Extron electronic MPA 401-70Vの取り付け説明書、サービスマニュアル、簡易説明書、またはExtron electronic MPA 401-70Vのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Extron electronic MPA 401-70Vの製品を使用するにあたって最も人気のある説明書を閲覧できます。

Extron electronic MPA 401-70Vデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがExtron electronic MPA 401-70Vを使用するのを助ける技術的文書のことです。説明書は通常、全てのExtron electronic MPA 401-70Vユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Extron electronicの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Extron electronic MPA 401-70Vの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははExtron electronic MPA 401-70Vの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Extron electronic MPA 401-70Vに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Extron electronic MPA 401-70Vデバイスの基本機能を使うにあたってのヒント。 Extron electronic MPA 401-70Vのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Extron electronic MPA 401-70Vに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるExtron electronic MPA 401-70Vのメーカー/サービスへの連絡先に関する情報。

Extron electronic MPA 401-70Vについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもExtron electronic MPA 401-70Vの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがExtron electronic MPA 401-70Vで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)