    BLUE FLAME VENT -FREE NA TURAL GAS HEA TER OWNER’S OPERA TION AND INST ALLA TION MANUAL Save this manual for future reference. FGHS30NGB 30,000 Btu/Hr Thermostat Model WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal in- jury, or loss of life. — Do not store or ...

  • Desa FGHS30NGB - page 2

    2 107340 BLUE FLAME NA TURAL GAS HEA TER Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include ...

  • Desa FGHS30NGB - page 3

    3 107340 OWNER’S MANUAL PRODUCT IDENTIFICA TION LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of National Fuel Gas Code, ANS Z223.1 , also known as NFPA 54*. *Available from: American National Standards Institute, Inc. 1430 Broadway New York, NY 10018 National Fire Prot ...

  • Desa FGHS30NGB - page 4

    4 107340 BLUE FLAME NA TURAL GAS HEA TER AIR FOR COMBUSTION AND VENTILA TION Today’s homes are built more energy effi- cient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During ...

  • Desa FGHS30NGB - page 5

    5 107340 OWNER’S MANUAL AIR FOR COMBUSTION AND VENTILA TION Continued DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless pas ...

  • Desa FGHS30NGB - page 6

    6 107340 BLUE FLAME NA TURAL GAS HEA TER Figure 3 - Ventilation Air from Outdoors Outlet Air Ventilated Attic Outlet Air Inlet Air Inlet Air Ventilated Crawl Space To Crawl Space To Attic Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts. You must provide two per- manent openings: one within 12" of the ...

  • Desa FGHS30NGB - page 7

    7 107340 OWNER’S MANUAL 36" 16.75" FLOOR CEILING Minimum Minimum to Top of Carpeting, Tile, or Other Combustible Material 6" Minimum From Sides of Heater Left Side Right Side INST ALLA TION Continued CHECK GAS TYPE Use only natural gas. If your gas supply is not natural, do not install heater. Call dealer where you bought heater fo ...

  • Desa FGHS30NGB - page 8

    8 107340 BLUE FLAME NA TURAL GAS HEA TER Figure 8 - Mounting Bracket Clearances WARNING: Maintain minimum clearances shown in Figure 7. If you can, provide greater clear- ances from floor and joining wall. Figure 7 - Removing Front Panel Of Heater Methods For Attaching Mounting Bracket To Wall Only use last hole on each end of mounting bracket to a ...

  • Desa FGHS30NGB - page 9

    9 107340 OWNER’S MANUAL Figure 9 - Folding Anchor INST ALLA TION Continued Attaching Mounting Bracket To Wall Note: Wall anchors, mounting screws, and spacers are in hardware package. The hard- ware package is provided with heater. Attaching To Wall Stud Method For attaching mounting bracket to wall studs 1. Drill holes at marked locations using ...

  • Desa FGHS30NGB - page 10

    10 107340 BLUE FLAME NA TURAL GAS HEA TER CONNECTING TO GAS SUPPLY WARNING: A qualified service person must connect heater to gas supply. Follow all local codes. WARNING: Never connect heater to private (non-utility) gas well. This gas is commonly known as wellhead gas. Typical Inlet Pipe Diameters FGHS30NG 1/2" or greater Installation must in ...

  • Desa FGHS30NGB - page 11

    11 107340 OWNER’S MANUAL O POS P O Figure 14 - Equipment Shutoff Valve Figure 15 - Checking Gas Joints Equipment Shutoff Valve Closed WARNING: Test all gas pip- ing and connections for leaks after installation or servicing. Correct all leaks at once. WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to ...

  • Desa FGHS30NGB - page 12

    12 107340 BLUE FLAME NA TURAL GAS HEA TER TO TURN OFF GAS TO APPLIANCE 1. Remove front panel (see Figur e 7, page 8). 2. Follow steps 1 thr ough 5 under Light- ing Instructions . 3. With contr ol knob pr essed in, str ike match. Hold match to pilot until pi- lot lights. 4. Keep contr ol knob pr essed in for 30 seconds after lighting pilot. After 30 ...

  • Desa FGHS30NGB - page 13

    13 107340 OWNER’S MANUAL Figure 19 - Incorrect Pilot Flame Pattern Thermocouple Pilot Burner INSPECTING BURNER Check pilot flame pattern and burner flame pattern often. PILOT FLAME PATTERN Figure 18 shows a correct pilot flame pattern. Figure 19 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touch- ing the thermocouple. ...

  • Desa FGHS30NGB - page 14

    14 107340 BLUE FLAME NA TURAL GAS HEA TER TROUBLESHOOTING Note: All troubleshooting items are listed in order of operation. WARNING: Turn off and un- plug heater and let cool before servicing. Only a qualified ser- vice person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ...

  • Desa FGHS30NGB - page 15

    15 107340 OWNER’S MANUAL OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition of burner Burner backfiring during combustion Yellow flame during burner combustion Slight smoke or odor during initial operation Heater produces a whistling noise when burner is lit White powder residue forming within de- flector unit or on ad ...

  • Desa FGHS30NGB - page 16

    16 107340 BLUE FLAME NA TURAL GAS HEA TER WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your ga ...

  • Desa FGHS30NGB - page 17

    17 107340 OWNER’S MANUAL Baltimore Electric 1348 Dixwell Avenue Hamden, CT 06514-0322 1-800-397-7553 203-248-7553 Parts Department Portable Heater Parts 342 N. County Rd. 400 East Valparaiso, IN 46383-9704 All States 219-462-7441 1-800-362-6951 sales@portableheaterparts.com techservice@portableheaterparts.com FBD 1349 Adams Street Bowling Green, ...

  • Desa FGHS30NGB - page 18

    18 107340 BLUE FLAME NA TURAL GAS HEA TER ILLUSTRA TED PA R T S BREAKDOWN THERMOSTAT MODEL FGHS30NGB 7 7 5 2 5 27 22 26 23 19 17 24 25 12 26 21 20 18 9 8 18 16 10 16 13 1 14 14 15 7 6 11 3 7 4 7 7 24-1 24-2 ODS/Pilot Assembly ...

  • Desa FGHS30NGB - page 19

    19 107340 OWNER’S MANUAL P ARTS LIST THERMOSTAT MODEL FGHS30NGB This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 17 of this manual. KEY NO. PART NUMBER DESCRIPTION QTY. 1 L98409-09 Cabinet Assembly 1 2 L98006-01 Front Panel Assembly 1 3 L98410-06 Deflecto ...

  • Desa FGHS30NGB - page 20

    20 107340 BLUE FLAME NA TURAL GAS HEA TER FAN KITS - UH1000FB, AND UHS1000FB For all models. Provides better heat distri- bution. Makes heater more efficient. Com- plete installation and operating instructions included. Manually-controlled - UH1000FB. Includes ON/OFF switch. Thermostatically-controlled - UHS1000FB. Includes three settings: ON/OFF/A ...

  • Desa FGHS30NGB - page 21

    21 107340 OWNER’S MANUAL NOTES _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _____________________________ ...

  • Desa FGHS30NGB - page 22

    KEEP THIS WARRANTY Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied. W ARRANTY INFORMA TION 107340-0 ...

メーカー Desa カテゴリー Electric Heater

Desa FGHS30NGBのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- FGHS30NGBの取扱説明書
- Desaの製品カード
- パンフレット
- またはDesa FGHS30NGBの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Desa FGHS30NGBの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Desa FGHS30NGBの取り付け説明書、サービスマニュアル、簡易説明書、またはDesa FGHS30NGBのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Desa FGHS30NGBの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Desa FGHS30NGBデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがDesa FGHS30NGBを使用するのを助ける技術的文書のことです。説明書は通常、全てのDesa FGHS30NGBユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Desaの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Desa FGHS30NGBの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははDesa FGHS30NGBの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Desa FGHS30NGBに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Desa FGHS30NGBデバイスの基本機能を使うにあたってのヒント。 Desa FGHS30NGBのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Desa FGHS30NGBに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるDesa FGHS30NGBのメーカー/サービスへの連絡先に関する情報。

Desa FGHS30NGBについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもDesa FGHS30NGBの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがDesa FGHS30NGBで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)