Charnwood LA30iBの取扱説明書

14ページ 0.33 mb
ダウンロード

ページに移動 of 14

Summary
  • Charnwood LA30iB - page 1

    Operating and Installation Instructions CHARNWOOD LA30iB Roomheater With Boiler Bishops Way, Newport, Isle Of Wight, PO3O 5WS, U.K. Tel: (01983) 527552 Fax: (01983) 821267 E-Mail: charnwood@ajwells.co.uk Internet: www.charnwood.com ...

  • Charnwood LA30iB - page 2

    ...

  • Charnwood LA30iB - page 3

    CHARNWOOD LA30iB Operating and Installation Instructions Contents Operating Instructions General Points ................................................... 3 Fuels ................................................................... 3 Door Operation .................................................. 3 Lighting ....................................... ...

  • Charnwood LA30iB - page 4

    ...

  • Charnwood LA30iB - page 5

    GENERAL POINTS Before lighting the fire check with the installer that the work and checks described in the installation instructions have been carried out correctly and that the chimney has been swept, is sound, and free from any obstructions. WARNING There must not be an extractor fan fitted in the same room as this appliance as this can cause the ...

  • Charnwood LA30iB - page 6

    anthracite, or homefire which should be burnt with the secondary air inlet open. RUNNING THE FIRE WITH THE DOORS OPEN The fire may be run with the doors open. This will result in a reduction in efficiency and hence heat output, particularly to the boiler. The more reactive fuels, like homefire, will burn better when the doors are open than fuels li ...

  • Charnwood LA30iB - page 7

    brightly before filling with fuel. If the central heating pump is off overnight then the thermostat may be left at the same setting for both day and night operation. If the central heating pump is on overnight then set the thermostat control to give the required level of heating. Some experimentation may be necessary to find the setting most suitab ...

  • Charnwood LA30iB - page 8

    TROUBLE SHOOTING Fire Will Not Burn. Check that: a) the air inlet is not obstructed in any way, b) chimneys and flueways are clear, c) a suitable fuel is being used, d) there is an adequate air supply into the room, e) an extractor fan is not fitted in the same room as the fire. Fire Blazing Out Of Control. Check that: a) the doors are tightly clos ...

  • Charnwood LA30iB - page 9

    HEA LTH AND SAFETY PRECAUTIONS Please take care when installing the appliance that the requirements of the Health and Safety at Work Act 1974 are met. Some types of fire cement are caustic and should not be allowed to come into contact with the skin. In case of contact wash with plenty of water. If there is a possibility of disturbing any asbestos ...

  • Charnwood LA30iB - page 10

    breast, one in the front to give access for infilling and fixing the flue pipe, and one in the side to give access for the pipework. CENTRAL HEATING SYSTEM The central heating system must comply with BS:5449 part 1. If the system is to be a combined heating and domestic hot water system then a double feed indirect hot water storage cylinder to BS:1 ...

  • Charnwood LA30iB - page 11

    with the centre-line of the chimney, and must also extend to the point where the chimney narrows to its final size. Any large voids must be filled and flaunched to the flue pipe to ensure that all soot deposits can be cleared when the appliance is swept. Ensure that the flue pipe is not obstructed or restricted in any way and that all joints are we ...

  • Charnwood LA30iB - page 12

    ASSEMB LY Fit the side panels, hood and top grid onto the appliance. Instructions for this are enclosed with the panel pack. Replace any internal parts previously removed. PRE LIGHTING CHECK Before initial lighting check the following points: 1. The bottom grate bars must all be fitted and should move freely and easily when the riddling mechanism i ...

  • Charnwood LA30iB - page 13

    Boiler tappings are 1" B.S. P. female. Two each side. FLUE C L 154 i/d 200 120 506 265 405 164 59 235 235 619 554 394 547 150° Charnwood LA30iB Overall Dimensions (Dimensions are in mm) Page 11 LA30iB 3.99 ...

  • Charnwood LA30iB - page 14

    32 34 31 20 27 19 21 26 12 16 7 5 36 33 40 42 15 39 14 13 28 29 23 19 25 24 24 9 8 35 11 10 41 37 17 33a 30 18 38 45 46 47 48 49 26 012/FW14 Riddler Rod 27 012/CG05 Idler Rod 28 008/FW48 Thermostat C/W Flap 29 008/BW57 Thermostat Flap 90mm Dia 30 005/RW05 Side Panel L.H. 31 005/RW04 Side Panel R.H. 32 005/RW06 Hood Panel 33 004/RW13 Panel Fixing Br ...

メーカー Charnwood カテゴリー Electric Heater

Charnwood LA30iBのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- LA30iBの取扱説明書
- Charnwoodの製品カード
- パンフレット
- またはCharnwood LA30iBの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Charnwood LA30iBの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Charnwood LA30iBの取り付け説明書、サービスマニュアル、簡易説明書、またはCharnwood LA30iBのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Charnwood LA30iBの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Charnwood LA30iBデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがCharnwood LA30iBを使用するのを助ける技術的文書のことです。説明書は通常、全てのCharnwood LA30iBユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Charnwoodの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Charnwood LA30iBの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははCharnwood LA30iBの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Charnwood LA30iBに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Charnwood LA30iBデバイスの基本機能を使うにあたってのヒント。 Charnwood LA30iBのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Charnwood LA30iBに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるCharnwood LA30iBのメーカー/サービスへの連絡先に関する情報。

Charnwood LA30iBについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもCharnwood LA30iBの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがCharnwood LA30iBで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)