White Rodgers 1F85-0477の取扱説明書

12ページ 1.29 mb
ダウンロード

ページに移動 of 12

Summary
  • White Rodgers 1F85-0477 - page 1

    1 Blue 4” Univ er sal T her mostat with Automa tic Heat/Cool Changeo v er Option Single Stage, Multi-Stage or Heat Pump Installation and Operating Instructions for Model: F AILURE T O READ AND FOLLO W ALL INSTRUCTIONS CAREFULL Y BEFORE INST ALLING OR OPERA TING THIS CONTROL COULD CA USE PERSONAL INJUR Y AND/OR PROPER TY D AMAGE. Save these instru ...

  • White Rodgers 1F85-0477 - page 2

    2 INST ALLA TION Thermostat installation and all components of the control system shall conf orm to Class II circuits per the NEC code. W ARNING ! Remove Old Thermostat A standard heat/cool thermostat consists of three basic par ts: 1. The cov er , which may be either a snap-on or hinge type . 2. The base, which is remo ved b y loosening all captiv ...

  • White Rodgers 1F85-0477 - page 3

    3 Single Stage 1 (SS1) Multi- Stage 2 (MS2) O Energized Constantly in Cool Mode B Energized Constantly in Heat, Off, Emergency Mode No Output Cool Mode 2nd Stage Cool Mode 1st Stage Blower/ Circulator Fan Energized on Call for Cool (and Heat if configured for Electric Heat) No Output Heat Mode 2nd Stage Heat Mode 1st Stage Optional* 24 V olt (Com- ...

  • White Rodgers 1F85-0477 - page 4

    4 WIRING DIA GRAMS Figure 5 – Single Stage or Multi-Stage System (No Heat Pump) with T wo T ransformer s Single Stage 1 (SS1) Multi- Stage 2 (MS2) No Output Cool Mode 2nd Stage Cool Mode 1st Stage Blower/ Circulator Fan Energized on Call for Cool (and Heat if configured for Electric Heat) No Output Heat Mode 2nd Stage Heat Mode 1st Stage Optional ...

  • White Rodgers 1F85-0477 - page 5

    5 11 10 9 1 8 7 6 5 4 3 2 12 Month Change Filter Call For Service Save T emp Hold P Date Set Set Schedule SYSTEM F AN Y ear R u n Hold Heat Mo T u We Th Fr Sa Su System On + 2 Heat Pump A uto Sched Cool Savings Em Auto A uto Cool Of f Time On Menu Set Mo P SYSTEM Heat FAN Auto Menu Room T emperature Setting T emperature System Indicator Fa n Indica ...

  • White Rodgers 1F85-0477 - page 6

    6 INST ALLER/CONFIGURA TION MENU With thermostat in Heat, Cool or Auto , in nor mal operation, press the Menu button f or at least 5 seconds. The displa y will show item #1 in the table belo w . Press Menu button to adv ance to the ne xt menu item. Press or to change an item option. INST ALLER/CONFIGURA TION MENU MENU REF . HP SS PRESS BUTT ON DISP ...

  • White Rodgers 1F85-0477 - page 7

    7 INST ALLER/CONFIGURA TION MENU 1) This control can be confi gured for: MS 2 – Multi-Stage System (no heat pump) HP 1 – Heat Pump with one stage of compressor HP 2 – Heat Pump with two stage compressor or two compressor system, Gas or Electric backup SS 1 – Single Stage System 2) GAS or Electric (ELE) fan operation. If the heating sys- te ...

  • White Rodgers 1F85-0477 - page 8

    8 OPERA TING Y OUR THERMOST A T Choose the Fan Setting (A uto or On) Press the F AN b utton to Auto or On. F an Auto is the most commonly selected setting and runs the f an only when the heating or cooling system is on. F an On r uns the f an continuously f or increased air circulation or to allow additional air cleaning. Choose the System Setting ...

  • White Rodgers 1F85-0477 - page 9

    9 The programmab le thermostats are programmed with the energy saving settings sho wn in the table belo w f or all days of the week. If this program suits y our needs, simply set the thermostat clock and press the R UN button. The table below sho ws the f actor y set heating and cooling schedule f or all days of the w eek. W ake Up (P eriod 1) Leav ...

  • White Rodgers 1F85-0477 - page 10

    10 W orksheet f or Re-Programming 7 Da y and 5+1+1 Day Program Cooling Program W ake Up (P eriod 1) Leave For W ork (P eriod 2) Return Home (P eriod 3) Go T o Bed (P eriod 4) MON 6:00 AM 75°F 8:00 AM 83°F 5:00 PM 75°F 10:00 PM 78°F TUE WED THU FRI SA T 6:00 AM 75°F 8:00 AM 83°F 5:00 PM 75°F 10:00 PM 78°F SUN 6:00 AM 75°F 8:00 AM 83°F 5:00 ...

  • White Rodgers 1F85-0477 - page 11

    11 Symptom Possib le Cause Correction Action No Heat/No Cool/No Fan (common problems) 1. Blown fuse or tripped circuit breaker . 2. Fur nace power s witch to OFF . 3. Fur nace blo wer compar tment door or panel loose or not properly installed. 4. Loose connection to ther mostat or system. Replace fuse or reset breaker . T urn switch to ON. Replace ...

  • White Rodgers 1F85-0477 - page 12

    12 www .white-rodger s.com HOMEO WNER HELP LINE: 1-800-284-2925 White-Rodgers is a division of Emerson Electric Co. The Emerson logo is a trademark and ser vice mark of Emerson Electric Co. ...

メーカー White Rodgers カテゴリー Thermostat

White Rodgers 1F85-0477のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 1F85-0477の取扱説明書
- White Rodgersの製品カード
- パンフレット
- またはWhite Rodgers 1F85-0477の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、White Rodgers 1F85-0477の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、White Rodgers 1F85-0477の取り付け説明書、サービスマニュアル、簡易説明書、またはWhite Rodgers 1F85-0477のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、White Rodgers 1F85-0477の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

White Rodgers 1F85-0477デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがWhite Rodgers 1F85-0477を使用するのを助ける技術的文書のことです。説明書は通常、全てのWhite Rodgers 1F85-0477ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

White Rodgersの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. White Rodgers 1F85-0477の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははWhite Rodgers 1F85-0477の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。White Rodgers 1F85-0477に関してこのドキュメントで見つけることができる全てのヒントの目次
3. White Rodgers 1F85-0477デバイスの基本機能を使うにあたってのヒント。 White Rodgers 1F85-0477のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。White Rodgers 1F85-0477に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるWhite Rodgers 1F85-0477のメーカー/サービスへの連絡先に関する情報。

White Rodgers 1F85-0477についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもWhite Rodgers 1F85-0477の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがWhite Rodgers 1F85-0477で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)