  • Datalogic DS2200 - page 1

    DS2200 Reference Manual ...

  • Datalogic DS2200 - page 2

    ...

  • Datalogic DS2200 - page 3

    DS2200 REFERENCE MANUAL ...

  • Datalogic DS2200 - page 4

    DATALOGIC S.p.A. Via Candini 2 40012 - Lippo di Calder ara di Reno Bologna - Italy DS2200 Reference Manual Ed.: 4/2006 ALL RIGHTS RESERVED Datalogic reserves the right to make modifi cati ons and im provements without prior notification . Datalogic shall not be liable fo r technical or editorial e rrors or omissions conta ined herein, nor for incid ...

  • Datalogic DS2200 - page 5

    CONTENTS REFERENCES ............................................................................................. v Conventio ns .................................................................................................. v Reference Docu mentation ............................................................................ v Services and Sup ...

  • Datalogic DS2200 - page 6

    4 MAINTENANCE ......................................................................................... 21 4.1 Cleanin g ...................................................................................................... 21 5 TECHNICAL FE ATURES ........................................................................... 22 GLOSSARY ............. ...

  • Datalogic DS2200 - page 7

    REFERENCES CONVENTIONS This manual uses the following conventio ns: “User” or “Operator” refers to anyone using a DS2100A. “Device” refers to the DS2100A. “You” refers to the System Admin istrator or Technical Support pers on using this manual to install, mount, operate, maintain or troublesho ot a DS2100A. REFERENCE DOCUMENTATION T ...

  • Datalogic DS2200 - page 8

    SAFETY PRECAUTIONS LASER SAFETY The following information i s provided to comply with the rules imposed by international authorities and refers to the correct use of the DS2200 scann er. Standard Regulations This scanner utilizes a lo w-power laser diode . Although starin g directly at the laser beam momentarily ca uses no known biologi ca l damage ...

  • Datalogic DS2200 - page 9

    The warning label in dicating exposure to laser li ght and the device classification is applied onto the body of the s canner (Figure A, 8): CAUTION-CLASS 3B LASER LI GHT WHEN OPEN A VO ID E XPOSU RE TO B EA M This product conforms to the ap plicable requi rem ents of 21 CFR1040 at the date o f manufacture. DATALOGIC S.p.A. Vi a Candini, 2 40012 Ca ...

  • Datalogic DS2200 - page 10

    POWER SUPPLY - This product is intended to be installed b y Qualified Pers onnel only. - DS2200 All Models: This device is intended to be supplied either by a UL Li sted NEC Class 2 power source, or a UL l isted ITE Limited Po wer Source (LPS), rated 5Vdc, minimum 0.4A. WEEE COMPLIANCE vii i ...

  • Datalogic DS2200 - page 11

    GENERAL VIEW DS2200 1 6 5 4 7 3 2 8 Figure A 1 2 3 4 5 6 7 8 Barcode Im age Input Window Laser Beam Output Window Pow er On LED Good Read LED Ext Tr ig LED TX D ata LED Laser Warni ng and Device Class Label Mounting Holes ix ...

  • Datalogic DS2200 - page 12

    GUIDE TO INSTALLATION The follo wing can be use d as a checklist to v erify all the n ecessary steps f or complete installation of the DS2200 scanner. 1. Read all information in the s ection "Saf ety Precautions” at the beginning of this manual. 2. Correctly position and m ount the scanner for barcode reading acc ording to the information in ...

  • Datalogic DS2200 - page 13

    INTRODUCTION 1 1 INTRODUCTION 1.1 PRODUCT DESCRIPTION The DS2200 scann er is a cost effective barcode r eader complete with decode r designed to satisf y demanding requirements associated with high performance scanning. The DS2200 ultra c ompact dimensions, based o n Datalogic's experi ence in miniaturized laser components, make the scanner&ap ...

  • Datalogic DS2200 - page 14

    DS2200 1 A security system allo ws the laser to activate onl y once the motor has reached the correct rotational speed; conseque ntly, the laser beam is generated after a slight delay from the power on of the scanner. 1.1.1 Indicators The four LEDs on the scanner indic ate the following: POWER ON (red), indicates the reader is connected to the po w ...

  • Datalogic DS2200 - page 15

    INTRODUCTION 1 The following models are therefore ava ilable: DS2200 - X X X X Optica l Resolution 1 = Sta ndard Resolution 2 = High Resolution Readin g Wi ndow Position 0 = Direct Optic Vers ion 0 = Linear 1 = Rast er Co mmunic at io n Interf a ce 1 = RS2 32 + RS 485 The following tables displa y each version’s reading perform ance. Version Max ...

  • Datalogic DS2200 - page 16

    DS2200 2 2 INSTALLATION 2.1 PACKAGE CONTENTS Verify that the DS2200 reader and all the parts supplied with the equipm ent are present and intact when opening the pa ckag ing; the list of parts includes: • DS2200 reader with cabl e • Installation Manual • Bar code test chart (PCS = 0.9) • DS2200 configuration program disk • Mounting kit: - ...

  • Datalogic DS2200 - page 17

    INSTALLATION 2 2.2 MECHANICAL INSTALLATION DS2200 can be installed to operate i n any position. There are three scre w holes (M2.5 x 5) on the body of the reader for mounting. T he diagram below gives all th e in formation requ ired for instal lation; refer to par. 2.4 for correct positioning of the scanner with respect to the code passage zone. DS ...

  • Datalogic DS2200 - page 18

    DS2200 2 2.2.1 Mounting DS2200 Using the DS2200 mounting bracket you can obtain the most suitable po sition for the reader as shown in the figure belo w: Pitch Skew 6 ...

  • Datalogic DS2200 - page 19

    INSTALLATION 2 2.3 ELECTRICAL CONNECTIONS The DS2200 cabl e is equipped with a 25-pin female D-s ub connector for conn ection with the power supply and input/output signal s: CA UTI ON Do not connect GND and SGND to d ifferent (external) ground references. GND and SGND are interna lly connected through filtering circuitry which can be perman ently ...

  • Datalogic DS2200 - page 20

    DS2200 2 2.3.1 Power Supply The following pins of the DS2200 conn ector are used: 13/9 25 1 VS GND CHASSIS USER INTE RFA CE GND V+ (5 Vdc) DS2200 Figure 4 - Power suppl y connections The power must be 5 Vdc only. 2.3.2 Main Serial Interface - RS485 Half-Duplex The RS485 half-dupl ex interface (3 wires + shiel d) is used for polled communic ation pr ...

  • Datalogic DS2200 - page 21

    INSTALLATION 2 The following figure s hows an example o f a multidrop configuration bet ween a Multiplexer and DS2200 scan ners. 120 Ohm max. 1200 m. RTX485 + RTX485 - Three wires + shi eld MULTIPLEXER # 1 DS2200 RTX485+ RTX485 - SGND # 0 DS2200 DS2200 # x (up to 31) 120 Ohm max. 2 m. 7 4 5 RS485 REF 7 4 5 7 4 5 SHIELD Figure 6 - DS2200 Multi drop ...

  • Datalogic DS2200 - page 22

    DS2200 2 7 SGND SGND TXD RXAUX 3 RXD TXAUX 2 USER INTERFACE DS2200 Figure 7 - RS232 auxiliar y interface connection s 2.3.4 Inputs The inputs available on the connector supp lied w ith the scanner are indicated below : Pin Name Function 19 E XT T RI G - external trigger (input -) 22 I/O REF I/O reference The EXT T RIG input is used to co nnect the ...

  • Datalogic DS2200 - page 23

    INSTALLATION 2 2.3.5 Outputs Two general p urpose outputs are av ailable. T hese outputs can only be connected as open collector configuratio ns. The following pins are present on the conn ector of the scanner: Pin Name Function 8 OUT1+ output 1 + 11 OUT2+ output 2 + 10, 12, 22 I/O REF I/O reference The meaning of the t wo outputs OUT1 and OUT2 can ...

  • Datalogic DS2200 - page 24

    DS2200 2 The Pitch angle is represent ed by the value P in Figure 10. Position the reader in order to minimize the Pitch angle. P Figure 10 - Pitch Angle The Skew angle is represented by the value S in Fig ur e 1 1. Position the reader to assure about 15° for the Skew angle. This avoids the direct reflection of the laser light emitted by the DS220 ...

  • Datalogic DS2200 - page 25

    INSTALLATION 2 2.5 TYPICAL LAYOUTS The following typical layouts refer to system hardware configurations . Dotted lines in the figures refer to optional hard ware configurations within the partic ular layout. These layouts also r equire the correct setup of the soft ware configuration parameters. Complete software configur ation procedures can be f ...

  • Datalogic DS2200 - page 26

    DS2200 2 The Master scanner is also conn ected to the Host on the RS232 auxiliar y serial interface. The External Trigger signal is unique to the system; there is a single reading p hase and a single message from the Master scanner to the Host computer. It is necessary to bring the External T rigger signal to all the scanners. The main and auxil ia ...

  • Datalogic DS2200 - page 27

    INSTALLATION 2 2.5.3 Multiplexer Each scanner is connecte d to a Multiplexer (for e xample MX4000) with the RS485 half-duplex main interface. 1 2 3 RS485 Main Interface Auxiliary Interface (Local Echo) External T rigger (f or On-Line mode ) Host MX4000 0 1 31 1 2 3 3 3 T X D A T A E X TTR IG GOODR E A D POWERON TX DATA EXT TRIG GOOD READ POWER ON T ...

  • Datalogic DS2200 - page 28

    DS2200 3 3 READING FEATURES The number of scans performed on the c ode by the D S2200 and therefore th e decoding capabilit y is influenced by the following parameters: • number of scans per second • code motion speed • label dimensions • scan direction with respect to code motion At least 5 scans during the code passage sh ould be allowed ...

  • Datalogic DS2200 - page 29

    READING FEATURES 3 For example, the DS2200 (500 sca ns/sec.) for a 25 mm high code moving at 50 0 mm/s performs: [(25/500) * 500] - 2 = 23 effective scans. 3.2 PICKET-FENCE MODE Direction of code movement at LS speed Laser beam DS2200 LW FW Figure 17 - "Picket Fe nce" scanning mode If scanning is paralle l to the code motion, (Figure 17), ...

  • Datalogic DS2200 - page 30

    DS2200 3 3.3 PERFORMANCE The DS2200 scann er is available i n different versions accord ing to the readin g performance. Version Max Code Resol ution Speed mm (mils) scans/s 1XXX 0.15 (6) 500 2XXX 0.07 (3) 500 Version Reading Distance 1XXX 50 mm (2.0 in) - 220 mm (8.7 in) on 0.60 mm (24 mils) codes 2XXX 40 mm (1.6 in) - 125 mm (4.9 in) on 0.20 mm ( ...

  • Datalogic DS2200 - page 31

    READING FEATURES 3 3.4 READING DIAGRAMS The following diagrams s how the reading distance for barco des with different densities. DS2200-1XXX (Standard Resolution) 2 1 0 1 5 4 3 2 3 4 5 (in) 01 3 21 6 (in) 45 7 8 9 02 0 4 0 6 0 80 100 120 140 160 180 200 220 240 260 (mm ) 120 100 80 60 40 20 0 20 40 60 80 100 120 (mm ) 0 ≥ 0.60 mm (24 mils) 0.50 ...

  • Datalogic DS2200 - page 32

    DS2200 3 DS2200-2XXX (High Resolution) 1 0 2 1 2 (in) 01 5 3 (in) 24 0 10 20 30 40 50 60 70 80 90 100 110 120 130 (m m) 60 50 40 30 20 10 0 10 20 30 40 50 60 (mm ) 0.10 m m (4 mils) 0.12 mm (5 mils) 0.15 mm (6 mils) ≥ 0.20 mm (8 mi ls) NOTE: (0,0) is the center of th e la ser beam output w indow. CONDITIONS: Code = Interleaved 2/5 or Code 39 PCS ...

  • Datalogic DS2200 - page 33

    MAINTENANCE 4 4 MAINTENANCE 4.1 CLEANING Clean the windows periodical ly for cont inued correct operation of the reader. Dust, dirt, etc. on the windows ma y alter the reading perfor mance. Repeat the operation frequentl y in particularly dirty environ ments. Use soft material and alcohol to cl ean the windows and avoid any abrasive substances. WA ...

  • Datalogic DS2200 - page 34

    DS2200 5 5 TECHNICAL FEATURES DS2200-1XXX DS2200-2XXX ELECTRICAL FEATURES Power Maximum input voltage 5 Vdc ± 5% Power consumption max. 2 W Serial Interfaces Main RS485 Half-Duplex Auxiliary RS232 Baud Rates 150 to 115200 Inputs External Trigger Outputs User-defined OUT1 and OUT2 V CE max. 50 Vdc Collector current max. 50 mA continuous V CE satura ...

  • Datalogic DS2200 - page 35

    TECHNICAL FEATURES 5 SOFTWARE FEATURES READABLE CODE SYMBOLOGIES • EAN/UPC (including Add-on 2 and Add-on 5) • Code 93 • 2/5 Interleaved • Code 128 • Code 39 (Standard and Full ASCII) • EAN 128 • Codabar • Pharmacode Other symbologies available on request Code Selection up to six codes during one reading phase Decoding Safety can en ...

  • Datalogic DS2200 - page 36

    GLOSSARY Ape rt ur e Term used on the required CDRH warning labels to describe the laser exit windo w. Barcode A pattern of variable- width bars and spaces which represents numeric or alphanumeric data i n machine-readable fo rm. The general format of a barc ode symbol consists of a leading margin, st art character, data or message character, check ...

  • Datalogic DS2200 - page 37

    EEPROM Electrically Erasable Progra mmable Read-Only Memory. An on-board non-volati le memory chip. Full Duplex Simultaneous, two-way, indep endent transmission in both directions. Half Duplex Transmission in either directi on, but not sim ultaneously. Host A computer that serves other terminals in a network, providing services such as network cont ...

  • Datalogic DS2200 - page 38

    Protocol A formal set of conventions governing th e formatting and relative timing of message exchange bet ween two communicating systems. Raster The process of projecting the laser be am at varied angles spaced evenl y from each other. Typically, the mirrore d rotor surfaces are angle d to create multiple scan lines instead of a single beam. Resol ...

  • Datalogic DS2200 - page 39

    Symbol A combination of characters inclu ding start/stop and checksum characters, as required, that form a complete scannable barcode. Tilt Rotation around the Z ax is. Used to describe the positi on of the barcode with respect to the laser scan line. See pars. 2.2.1 and 2.4. Trigger Signal A signal, typically prov ided by a photoelect ric sensor o ...

  • Datalogic DS2200 - page 40

    INDEX A Accessories; 3 C Cleaning; 21 E Electrical Connections; 7 G General View; ix Glossary; 24 Guide to Installation; x I Inputs; 10 Installation; 4 Interfaces Auxiliary – RS232; 9 Main – RS485 Half Duplex; 8 L Laser Safety; vi LED Indicators; 2 M Maintenance; 21 Model Description; 2 Mounting DS2200; 6 O Outputs; 11 P Package Contents; 4 Per ...

  • Datalogic DS2200 - page 41

    DATA LOGIC S.p.A ., Via Candini, 2 40012 - Lippo di Calderara Bologna - Italy 05 dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el DS2200-XXXX Laser Scanner e tutti i suoi modelli and all its models et tous ses modèle s und seine modelle y todos sus mo delos sono conformi alle Direttive del Consiglio Europe ...

メーカー Datalogic カテゴリー Scanner

Datalogic DS2200のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- DS2200の取扱説明書
- Datalogicの製品カード
- パンフレット
- またはDatalogic DS2200の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Datalogic DS2200の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Datalogic DS2200の取り付け説明書、サービスマニュアル、簡易説明書、またはDatalogic DS2200のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Datalogic DS2200の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Datalogic DS2200デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがDatalogic DS2200を使用するのを助ける技術的文書のことです。説明書は通常、全てのDatalogic DS2200ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Datalogicの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Datalogic DS2200の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははDatalogic DS2200の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Datalogic DS2200に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Datalogic DS2200デバイスの基本機能を使うにあたってのヒント。 Datalogic DS2200のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Datalogic DS2200に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるDatalogic DS2200のメーカー/サービスへの連絡先に関する情報。

Datalogic DS2200についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもDatalogic DS2200の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがDatalogic DS2200で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください