    Dynamic Cook ing Sys tems, Inc. ISLAND VENT HOOD USE AND CARE INST ALLA TION INSTRUCTIONS DCS-IVH-48 DCS-IVH-36 ...

  • DCS -IVH-48 - page 2

    A MESSAGE TO OUR CUSTOMERS Thank you for selecting this Dynamic Cooking Systems Professional Island Vent Hood. Because of this appliance ’ s unique features we have developed this Installation and Use Guide. It contains valuable information on how to properly operate and maintain your new appliance for years of safe and enjoyable use. To help ser ...

  • DCS -IVH-48 - page 3

    Introduction 1 Before proceeding with installation, please read this installation guide and observe all safety precautions and warnings. NOTE: Installation of this DCS Island Vent Hood must comply with all local codes. IMPORTANT- Save these instructions for the Local Electrical Inspector ’ s use. INSTALLER- Please leave these instructions with th ...

  • DCS -IVH-48 - page 4

    Follow These Precautions Important Safety Instructions 2 CAUTION - TO REDUCE THE RISK OF ELECTRICAL SHOCK OR INJURY TO PERSONS ALL VENT HOODS MUST BE INSTALLED WITH VENTILATORS THAT HAVE BEEN APPROVED FOR USE WITH THE HOOD. Make up air may be necessary to prevent air flowing down chimney, unsealed door, window, or fire place opening. WARNING - TO R ...

  • DCS -IVH-48 - page 5

    Island Vent Hoods DCS-IVH-48 & DCS-IVH-36 Features 3 The Dynamic Cooking Systems Island Vent Hood Models; DCS IVH 48 , DCS IVH 36, have been designed with the ultimate in household conve- nience in mind. Features include a high capacity, variable speed blower with speed controller, commercial style dishwasher-safe filters, easy to clean inside ...

  • DCS -IVH-48 - page 6

    We recommend that a backdraft damper be used in all Vent Hood installations. Cold weather installations necessitate the use of a backdraft damper to minimize the flow of cold air into the room. A non-metallic thermal break should also be installed to mini- mize conduction of outside temperatures through the ductwork. Locate the thermal break as clo ...

  • DCS -IVH-48 - page 7

    Product and Venting Specifications Specifications 5 843fi21 16" 52 5/8" 30" 16" FR ONT VIEW SIDE VIEW 34 5/8" 12" 12" 34 5/8" DCS-IVH-48 DCS-IVH-48 DCS-IVH-36 DCS-IVH-36 VENT HOOD DIMENSIONS nt ro l 30" 12" T OP VIEW o f DCS-IVH 18" 12" T OP VIEW o f DCS-IVH v enting specs 7" Ø v ent ...

  • DCS -IVH-48 - page 8

    Site Preparation Site Preparation and Installation Guidelines 6 You will need to create a secure soffit structure to mount the Island Vent Hood to the ceiling. We suggest using 1 1/2 “ by 3 1/2 “ wood cut to fit the installation as shown in the following pages. The soffit mounting to the top of the Island Vent Hood will be 10 7/8 “ in length ...

  • DCS -IVH-48 - page 9

    Create your Soffit Struct first and attach Soffit B to each side with screws pr 36" ISLAND VENT HOOD SOFFIT MOUN 6 Mounting Scr ew s SOFFIT BRACKETS SCREWED TO BOTH SIDES OF SOFFIT STRUCTURE SCREW SUPPORT BARS ON BOTH SIDES AS SHOWN CREATE YOUR SOFFIT STRUCTURE ACCORDING TO THE CEILING HEIGHT THEN ATTACH IT TO THE CEILING JOIST. 843 fig 1 s ke ...

  • DCS -IVH-48 - page 10

    DCS-IVH-48 Island Vent Hood Soffit Installation 8 A TT A CH SOFFIT BRA CKETS ON 4 CORNER S OF THE SOFFIT STR UCTURE 2 SUPPOR T BA RS SOFFIT ASSEMBLY FOR DCS-IVH-48 10 7 / 8 " HEIGHT WILL VARY ACCORDING TO CEILING HEIGHT 28 7 / 8 " 4 SOFFIT BRA CKETS The dimensions giv en are f or a 1 THE DIMENSIONS GIVEN ARE FOR A 1/2 INCH DRYWALL DUCT CO ...

  • DCS -IVH-48 - page 11

    Soffit for DCS-IVH-48 Island Vent Hood Soffit Installation 28 7/8 " 10 7/8 " T OP VIEW o f DCS-IVH 48 SIDE VIEW f or DCS-IVH 48 S OFFIT STR UCTU 1 1/2 " x 3 1/2 " So f fit 3 1/2 "c ent erline t o cen t erline measuremen t f rom scr e w t o scr ew W ood S tructure 1 1/2 " x 3 1/2 " So f (4) so ffit br ack e ts The ...

  • DCS -IVH-48 - page 12

    Diagrams for DCS-IVH-48 Island Vent Hood Soffit Installation 10 counter top level 843 fig 4 FR ONT VIEW o f DCS-IVH 48 30" Min. t o cooking surf a ce Support Bars Ceiling Floor Typical 96" Ceiling Sho wn Duct Co v er NO TE: Duct Co v er height will v ary acco r ding t o ceiling heigh t these mus t be cust om built. 6 Moun ting Scre ws Sol ...

  • DCS -IVH-48 - page 13

    Duct Accessories General Ducting Information DCS-IVH-48 Requirements DCS-IVH-36 Requirements When planning the path for ducting to the outside, keep in mind the following guide- lines: - Minimize use of elbows and transitions in ductwork as to maximize air flow to out- side of building. An efficient airflow path contributes to the overall efficienc ...

  • DCS -IVH-48 - page 14

    Controls Care And Use 12 Hood Lighting Blower We recommend you turn your hood on before you begin cooking to establish fresh airflow. After you have finished cooking, let the blower run for a few minutes to clear the air and help keep the kitchen fresh and clean. The Blower is operated with 2 controls. The switch adjacent to the speed control turns ...

  • DCS -IVH-48 - page 15

    Care And Use 13 When cool the appliance can be cleaned with hot soapy water, rinsed, dried and buffed to a shine with a soft, heavy pile cloth. Always try this first, as it is the mildest form of cleaning. 1. Some brands of cleaners are harsher than others. Read their instructions. Try on a small inconspicuous area first. 2. To avoid marring the su ...

  • DCS -IVH-48 - page 16

    Cleaning the Grease Tray Care And Use 14 Location of grease tray DCS-IVH-36 DCS-IVH-48 Remove filter(s) by gently pulling up and out. The grease trays can easily be reached once the filters are removed. Grease collection trays are easily accessible at the center beneath the filter. See illustration below for location. ...

  • DCS -IVH-48 - page 17

    DCS-IVH-48 & DCS-IVH-36 Island Vent Hood Wiring Diagram 15 ...

  • DCS -IVH-48 - page 18

    16 W arranty Information Length of Warranty One (1) Year Full parts and Labor Covers the entire product Five (5) Years Limited Switches and motor All repair labor and parts found to be defective due to materials or workmanship for one full year from date of purchase. Service must be provided by an Authorized Factory Service Agent during normal work ...

  • DCS -IVH-48 - page 19

    How To Obtain Service: Ser vice 17 For warranty service, contact your local DCS authorized service agency. Be prepared to provide the Model Number, Serial Number, and date of installa- tion, and a brief description of the problem. If you need assistance in locating the authorized service agency in your area please contact the DCS Consumer Service D ...

  • DCS -IVH-48 - page 20

    Litho in USA 8-99 Part No. 10843 rev.2 As product improvement is an ongoing process at DCS, we reserve the right to change specifications or design without notice. Dynamic Cook ing Sy s tems , Inc. 5800 Skylab Road, Huntington Beach, CA. 92647 Tel: (714) 372-7000 Fax: (714) 372-7001 Parts/Customer Service (888) 281-5698 ...

メーカー DCS カテゴリー Ventilation Hood

DCS -IVH-48のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- -IVH-48の取扱説明書
- DCSの製品カード
- パンフレット
- またはDCS -IVH-48の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、DCS -IVH-48の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、DCS -IVH-48の取り付け説明書、サービスマニュアル、簡易説明書、またはDCS -IVH-48のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、DCS -IVH-48の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

DCS -IVH-48デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがDCS -IVH-48を使用するのを助ける技術的文書のことです。説明書は通常、全てのDCS -IVH-48ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

DCSの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. DCS -IVH-48の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははDCS -IVH-48の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。DCS -IVH-48に関してこのドキュメントで見つけることができる全てのヒントの目次
3. DCS -IVH-48デバイスの基本機能を使うにあたってのヒント。 DCS -IVH-48のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。DCS -IVH-48に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるDCS -IVH-48のメーカー/サービスへの連絡先に関する情報。

DCS -IVH-48についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもDCS -IVH-48の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがDCS -IVH-48で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)