United States Stove 2007B - page 1
1 owner's manual PEDEST AL PL A TE HEA TER moDel: 2007B ...
-
United States Stove 2007B - page 2
2 Y ou've purchased a heater from North America's oldest manufacturer of wood burning products. By heating with wood you're helping to CONSERVE ENERGY! Wood is our only Renewable Energy Resource. Please do your part to preserve our wood supply . Plant at least one tree each year . Futu ...
-
United States Stove 2007B - page 3
3 SAFETY NOTICE: If this heater is not properly installed a house re may result. For your safety, follow the installation directions. Contact local building or re ofcials about restrictions and installation inspection requirements in your area. ...
-
United States Stove 2007B - page 4
4 Keep the chimney connection as short as possible. The heater must have its own chimney ue. Do not connect any other appliance to the same ue. If there is no chim- ney where you wish to place the heater, you can use a UL Listed Type 103 HT, Solid Fuel, Factory Built Chimney. Place the heater on solid masonry or solid concrete. When the heate ...
-
United States Stove 2007B - page 5
5 This heater comes equipped with a cast-iron ue collar with holes to mount the solid damper as shown below. Flue Collar - 40292 Solid Damper - 40398 5/16-18 x 1-1/2" Bolts (3 req.) Weld Tab (3 req.) Gasket ...
-
United States Stove 2007B - page 6
6 KEY DESCRIPTION PART NO. QTY. 1 Blower Motor 80442 1 2 Blower Housing Front 25090B 1 3 Blower Housing Back 25089B 1 4 Power Supply Cord 80232 1 5 Rheostat w/Nut and Knob 80090 1 6 Strain Relief Bushing 80109 1 N/S 10AB x 3/8 Hex Zinc Screw 83222 8 N/S #12 x 3/4 Teks Screw C23799 4 ? ...
-
United States Stove 2007B - page 7
7 T wo basic types of chimneys are approved for use with solid fuel. Factory-built and masonry . Factory-built chimney must comply with UL standard in the US. Do not expect your stove or furnace to create draft. Draft is not a function of the appliance. Draft is purely a function of the chimney ...
-
United States Stove 2007B - page 8
8 Many people may wish to convert an existing replace to heater use. Usually, safe connection of stovepipe to a masonry chimney requires more effort than c onnection to a prefabricated chimney. The replace must be tightly closed and sealed at the damper in the ue. Goo ...
-
United States Stove 2007B - page 9
9 When considering a masonry chimney , round tiles are preferable to square or rectangular , as round tiles have much better airow character- istics and are far easier to clean. Unfortunately , most North American chimneys use square or rectangular tile liners that are really designed for open replaces, not stoves or furnaces. Of most importa ...
-
United States Stove 2007B - page 10
10 Connection of the stovepipe directly into the existing masonry chimney over the replace opening is a more desirable method. This instal- lation performs better , yielding more h ...
-
United States Stove 2007B - page 11
11 1. Crimped end of the pipe must be installed toward the heater . The pipe should slide inside the ue collar . The pipe should be rmly attached to the ue collar with 3 screws and sealed with furnace cement. 2. Slope any horizontal pipe upward toward the chimney at least 1/4 " inch for each foot of horizontal run. 3. Y ou must have a ...
-
United States Stove 2007B - page 12
12 Use Hardwood that has been split and air-dried to obtain maxi- mum burning efciency . 1. Open door and place paper and kindling in the rebox. 2. Light the re and close the doors u ...
-
United States Stove 2007B - page 13
13 Key Part No. Description Qty . 1 69427B Ash Pan 1 2 40487 Ash Dump Cover 1 3 24103 ½ Firebrick 2 4 89066 Full Firebrick 17 5 69429 Feed Door 1 N/S AC0600 Feed Door Gasket & Silicone 1 6 PL8535-01 Door Handle 1 7 891 135 Spring Handle (Nickel) 1 8 AC09185 Door Barrell/Roll ...
-
United States Stove 2007B - page 14
14 ? ...
-
United States Stove 2007B - page 15
15 1. Be sure heater has cooled before beginning. 2. Remove 12, 8-32 x ¼ screws and glass re- tainers with screw driver. 3. Remove damaged glass (2). 4. To reinstall glass, follow steps 1-2 in reverse order. Be sure to replace the gasket on the glass. 5. Caution: ...
-
United States Stove 2007B - page 16
16 THIS MANUAL WILL HELP YOU OBT AIN EFFICIENT , DEPENDABLE SER VICE FROM YOUR 2007B HEA TER, AND ENABLE YOU TO ORDER REP AIR P ARTS CORRECTL Y . KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE. WHEN WRITING, AL W A YS GIVE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLA TE A TT ACHED T O THE HEA TER. WHEN ORDERING REP AIR P ARTS, AL W A YS GIV ...