    SWRU157D 2008 Low-Power RF ZigBee Sensor Monitor U se r ' s G u i d e User's Guide ...

  • Texas Instruments SWRU157D - page 2

    ...

  • Texas Instruments SWRU157D - page 3

    1 Contents ZIGBEE SENSOR MONITOR ................................................................................................................... 1 1. INTRODUCTION ................................................................................................................... ............ 2 1.1. CC2530ZDK ..................................... ...

  • Texas Instruments SWRU157D - page 4

    2 1. Introduction ZigBee Sensor Monitor (or ZSensorMonitor 1 ) is a PC application that will be used to monitor the sensors in a ZigBee Network. ZSensorMonitor can be used together with either the CC2530ZDK or an eZ430-RF2480 kit. The network is formed when setting up the basic out of the box demo included either of the kits. In the case of eZ430-R ...

  • Texas Instruments SWRU157D - page 5

    3 2. Inst allation The installation of ZSensorMonitor is very straight forward. Download the zip file from internet and unzip the setup file. Double click on the setup file and follow the instructions. 3. eZ430-RF2480 Driver Inst allation This section is only relevant if the eZ430-RF2480 kit platform is used. Note: When using eZ430-RF2480 the PC ap ...

  • Texas Instruments SWRU157D - page 6

    4 Select “Install the software automatically” and click next. If the IAR kickstart for MSP430 has been installed before this application, it might be that this dialog will pop up and ask the user to select one of the two inf files. Both inf files are equal and it doesn’t matter which one that is selected. Either should work fine. The installa ...

  • Texas Instruments SWRU157D - page 7

    5 If this warning appears, the option “Continue Anyway” must be selected in order to install the driver. This dialog will be shown when everything has been successfully installed. Click Finish to close the wizard. ...

  • Texas Instruments SWRU157D - page 8

    6 3.2. Windows Vista The first time the USB dongle (sink) is connected to the PC, the new HW is detected and the system will ask to install driver software. Select “Locate and install driver software”. Select “I don’t have the disc. Show me other options.” Select “Browse my computer for driver software.” ...

  • Texas Instruments SWRU157D - page 9

    7 The required “inf” file will be installed together with the application. Browse to the directory of the application and select the sub directory “Drivers”. Click Next to continue. Select “Install this driver software anyway” At the end the software should be successfully installed. Click Close to end the installation. ...

  • Texas Instruments SWRU157D - page 10

    8 4. User Interface The user interface is developed to be as simple as possible with only a few buttons and input fields. When the eZ430-RF2480 dongle is connected to the PC, the application will search for an applicable COM port and start reading if a connection is successfully established. Below is a screenshot showing a ZigBee Coordinator, Route ...

  • Texas Instruments SWRU157D - page 11

    9 4.1. Toolbar Pause captur ing dat a fr om the ser ial COM port Stop capt uri ng data fr om the ser ial COM port Star t capt uri ng data fr om the ser ial COM port Drop down li st wi th al l the avai labl e COM ports Refres h li st of seri al COM ports Configur ati on Open appli cati on user manual About info rm a tio n Start l ogging t o file O p ...

  • Texas Instruments SWRU157D - page 12

    10 4.3. Data logging and playback It is possible to capture the data traffic on the serial port to a log file for debugging and playback purposes. The log file is pure ASCII text which displays a time-stamp and the raw data in hexadecimal format. Data logging is started by clicking the button . The user will then be requested to provide a file usin ...

  • Texas Instruments SWRU157D - page 13

    11 4.4. Help The User’s Manual is a file which opens when the “help” button is clicked. The “About” button can be clicked to obtain information about the application. 4.5. Configuration Click on the “Configuration” button and the settings dialog will appear. ...

  • Texas Instruments SWRU157D - page 14

    12 Temperature unit Celsius or Fahrenheit can be selected. Time interval The timestamp of each node will be checked regularly to see if any message has been received within the given time interval. If the elapsed time is longer than specified, the Node will be removed from the screen. ...

  • Texas Instruments SWRU157D - page 15

    13 4.6. Network View The PC demo will always display one node on the top of the screen, the Sink. Below the Sink the presence of additional network nodes will be displayed as they are detected. Be aware that nodes may place themselves on top of existing nodes when they first appear, but can easily be dragged away with the mouse. The various states ...

  • Texas Instruments SWRU157D - page 16

    14 voltage and a timestamp from when the last message was received from this node. The source node will blink each time a message is received by the connected Sink node. The role of each node is also indicated if the mouse is held over the node for more than a second. The nodes are connected with arrows to show the relationship between parent and c ...

  • Texas Instruments SWRU157D - page 17

    15 5. T roubleshooting 5.1. Incorrect temperature values If the temperature is much different from the expected value, this is because the temperature sensor is not calibrated. 5.2. Status of the connected dongle NB! This section only applies to the eZ430-RF2480. It is possible for the status of the connected dongle to get out of synchronization if ...

  • Texas Instruments SWRU157D - page 18

    16 When the eZ430-RF2480 is removed, these dev ice drivers should disappear from the view in the Device Manager. If they don’t disappear, a restart of the PC will be necessary. Check that the “MSP430” device is availabl e in the drop down list of available COM ports. The serial COM port. The composite device ...

  • Texas Instruments SWRU157D - page 19

    17 5.6. Not able to start the application If an error message about missing the msvcp80.dll is received, or the error message shown below appears when attempting to start the application, you may be required to install an additional package from Microsoft. The package contains some additional runtime components needed by applications developed with ...

  • Texas Instruments SWRU157D - page 20

    18 Document History Revision Date Description/Changes swru157 08/03/2008 Initial release. swru157a 08/05/2009 • Added logging and playback • Changed document name • Added support for CC2530 Z- Stack Sensor Demo • Added status bar swru157d 25/08/2009 Changed document title ...

  • Texas Instruments SWRU157D - page 21

    19 IMPORTA NT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements,and other changes to its products and services at any time and to discontinue any product or service without notice. Customers shouldobtain the latest relevant information before pl acing ord ...

メーカー Texas Instruments カテゴリー Computer Monitor

Texas Instruments SWRU157Dのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- SWRU157Dの取扱説明書
- Texas Instrumentsの製品カード
- パンフレット
- またはTexas Instruments SWRU157Dの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Texas Instruments SWRU157Dの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Texas Instruments SWRU157Dの取り付け説明書、サービスマニュアル、簡易説明書、またはTexas Instruments SWRU157Dのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Texas Instruments SWRU157Dの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Texas Instruments SWRU157Dデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがTexas Instruments SWRU157Dを使用するのを助ける技術的文書のことです。説明書は通常、全てのTexas Instruments SWRU157Dユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Texas Instrumentsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Texas Instruments SWRU157Dの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははTexas Instruments SWRU157Dの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Texas Instruments SWRU157Dに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Texas Instruments SWRU157Dデバイスの基本機能を使うにあたってのヒント。 Texas Instruments SWRU157Dのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Texas Instruments SWRU157Dに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるTexas Instruments SWRU157Dのメーカー/サービスへの連絡先に関する情報。

Texas Instruments SWRU157Dについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもTexas Instruments SWRU157Dの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがTexas Instruments SWRU157Dで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)