    1000-90 Communications Software LI-6252 CO 2 Analyzer LI-6262 CO 2 /H 2 O Analyzer LI-3000A Portable Area Meter LI-1000 Data Logger LI-1400 Data Logger LI-1600 Steady State Porometer LAI-2000 Plant Canopy Analyzer LI-1800 Portable Spectroradiometer LI-1200S Minimum Data Set Recorder LI-6200 Portable Photosynthesis System LI-6400 Portable Photosynth ...

  • IBM 1000-90 - page 2

    1000-90 Communication and Utility Software for LI-COR Instruments Publication No. LDL102-8903 January, 1991 Revised April, 1992 Revision 2, January, 1998 LI-COR, inc. 4421 Superior Street P.O. Box 4425 Lincoln, Nebraska 68504 USA Telephone: (402) 467-3576 FAX: 402-467-2819 Toll-free 1-800-447-3576 (US & Canada) e-mail: envsales@env.licor.com ht ...

  • IBM 1000-90 - page 3

    LI-COR Software Product License Agreement and Limited Warranty License Agreement Customer may not reverse assemble or decompile this software. Customer may make copies of the software for archival purposes, or to facilitate its use with the mass storage media of a particular computer (e.g. copy to hard disk). Customer may make copies of the softwar ...

  • IBM 1000-90 - page 4

    General Information 3 General Information Contents page COMM.EXE ......................................................................................................................................... 5 Sending Files to the Computer ....................................................................................................... 7 LAI-2000 ...

  • IBM 1000-90 - page 5

    4 General Information Documentation Files READ.ME - Recent changes. *.HLP - Help files. LCONFIG.LCR - List of configurations and help files. REFORMAT.PAS - Source code for REFORMAT program. The 1000-90 programs are approximately 243K bytes in size, and run on any IBM PC/XT/AT/PS/2 or true IBM compatible computer. ...

  • IBM 1000-90 - page 6

    COMM.EXE 5 COMM.EXE (General Purpose) Installation No special installation procedures are required to install the 1000-90 program. Make a backup copy of the diskette if you plan to use the 1000-90 program directly from the floppy disk, or copy the contents of the diskette onto a hard disk drive in your computer. The 1000-90 program is a general pur ...

  • IBM 1000-90 - page 7

    6 COMM.EXE they appear in the existing configuration files (i.e., Com1 or Com2:Baud Rate, Data Bits, Stop Bits, and Parity). Any text editor can also be used to append the 'LCONFIG.LCR' file as well. Model the new entries as they appear in this file, and save the file as a Text (ASCII) file. F2 Change serial (COM) ports. If more than 1 CO ...

  • IBM 1000-90 - page 8

    COMM.EXE 7 Sending Files to the Computer LAI-2000Plant Canopy Analyzer The LAI-2000 is configured as a DCE device. Connect the LAI- 2000 to your computer using the printer cable provided with the instrument. To send files from the LAI-2000 to a computer, use the following functions, found in the COMM execute list: FCT 31 - Configure the I/O port fo ...

  • IBM 1000-90 - page 9

    8 COMM.EXE The data dump can be aborted by pressing the OUT key again. LI-1400 DataLogger The LI-1400 is configured as a DTE device. Most computers can be connected to the LI-1400 using the 1400-550 printer cable. To send files from the LI-1400 to a computer, follow these steps: 1. Use the Setup Hardware menu to set the Printing baud rate to 9600. ...

  • IBM 1000-90 - page 10

    COMM.EXE 9 LI-3000A Portable Area Meter The LI-3000A is configured as a DCE device. Most computers can be connected to the LI-3000A using the 1000-04 printer cable and a female-to-female gender changer. To send files from the LI-3000A to a computer, use the following functions: 1. Press the MENU key to access the functions needed to transfer data. ...

  • IBM 1000-90 - page 11

    10 COMM.EXE LI-1800 (UW) Portable Spectroradiometers The LI-1800 and LI-1800UW Portable Spectroradiometers are configured as DCE devices. There are two ways to connect the computer to the LI-1800 or LI-1800UW. Terminal Port 1. Connect the computer to the terminal port on the LI-1800 using the 1000-04 printer cable, and use the COMM program as a ter ...

  • IBM 1000-90 - page 12

    COMM.EXE 11 FCT 53 - Output a range of page files. The print format is selected by the PRN FMT (U/S) option in FCT 42. The system format is selected in FCT D8, and the user format is defined in FCT D9. Any list can be printed by pressing PRINT while viewing the list. LI-6400 Portable Photosynthesis System The LI-6400 is configured as a DTE device. ...

  • IBM 1000-90 - page 13

    12 COMM.EXE The LI-6252 CO 2 and LI-6262 CO 2 /H 2 O Analyzers are both configured as DCE devices, and can be connected to most computers using the 1000-04 printer cable. The 1800-04 printer cable will work with most computers that have a 9-pin AT-style RS-232C port. To send data from the LI-6252 or LI-6262 to a computer, follow these steps: 1. Use ...

  • IBM 1000-90 - page 14

    COMM.EXE 13 pressing <CTRL>Q. If you encounter data transmission problems, change the volume on the tape recorder and try again. Cables There are 2 types of RS-232C devices: DTE (Data Terminal Equipment) and DCE (Data Communications Equipment). If a DTE device is connected directly (pin-for-pin) to another DTE device then communication cannot ...

  • IBM 1000-90 - page 15

    14 COMM.EXE This device cable configured as cable part # LI-6200 Male DCE LI-6000 Male DCE LI-1000 Female DCE 1000-09 LAI-2000 Female DTE 2000-02 LI-3000A Male DTE 1800-04 LI-1800 terminal port Male DTE 1800-04 LI-1800UW terminal port Male DTE 1800-04 LI-6252 & LI-6262 Male DTE 1800-04 The cable would then plug directly into the instrument. If ...

  • IBM 1000-90 - page 16

    EQUIP.EXE 15 EQUIP.EXE (General Purpose) EQUIP.EXE is a diagnostics program that is useful for determining hardware compatability problems between your computer and the instrument that is connected to it. This program indicates the status of the major modem lines on all RS-232C ports in your computer. Run the program by typing EQUIP and pressing th ...

  • IBM 1000-90 - page 17

    16 EQUIP.EXE CONFIGURED - lists baud rate, data bits, stop bits, and parity. RTS (4) - Ready To Send status, transmitted on modem cable line 4. CTS (5) - Clear To Send status, transmitted on modem cable line 5. DSR (6) - Data Set Ready status, transmitted on modem cable line 6. CD (8) - Carrier Detect status, transmitted on modem cable line 8. DTR ...

  • IBM 1000-90 - page 18

    REFORMAT.COM 17 REFORMAT.COM (LI-1000 Data) REFORMAT.COM will reformat an LI-1000 data file that was output using "V" (vertical) format. As printed by the LI-1000, the data is sequential in time. REFORMAT creates a file that has all the channels grouped, and sorted by time within each group. For example: Source File... 871013 0935 1M-2.54 ...

  • IBM 1000-90 - page 19

    18 REFORMAT.COM 871013 0940 6T-8.643E-07 6H-2.746E-05 6L-2.441E-05 To run this program, log onto the proper drive and at the DOS prompt type REFORMAT <source file> <destination> where <source> and <destination> are the appropriate file specifiers. If these file specifiers are not entered, you will be asked the name of the fi ...

  • IBM 1000-90 - page 20

    R1600.EXE 19 R1600.EXE (LI-1600 Data) General Information R1600.EXE will reformat an LI-1600 data file that was output using the 2-line format which the instrument produces. The R1600 program will also add an offset time stamp to any LI-1600 data file, if desired, which will be added to the #S (time since instrument turn on, in seconds) values to p ...

  • IBM 1000-90 - page 21

    20 R1600.EXE where <source> is the appropriate file specifier, and <destination> is the print destination [optional; the default destination is CON (console)]. To add an offset time to the source file, type r1600 <source> <destination> <hh:mm:ss> For example, typing " r1600 corn.dat corn.prn 14:30:00" at the ...

  • IBM 1000-90 - page 22

    ® 4421 Superior Street ● P.O. Box 4425 ● Lincoln, Nebraska 68504 USA Phone: 402-467-3576 ● FAX: 402-467-2819 Toll-free 1-800-447-3576 (U.S. & Canada) E-mail: envsales@env.licor.com Internet: http://www.licor.com ...

メーカー IBM カテゴリー Marine Radio

IBM 1000-90のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 1000-90の取扱説明書
- IBMの製品カード
- パンフレット
- またはIBM 1000-90の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、IBM 1000-90の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、IBM 1000-90の取り付け説明書、サービスマニュアル、簡易説明書、またはIBM 1000-90のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、IBM 1000-90の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

IBM 1000-90デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがIBM 1000-90を使用するのを助ける技術的文書のことです。説明書は通常、全てのIBM 1000-90ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

IBMの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. IBM 1000-90の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははIBM 1000-90の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。IBM 1000-90に関してこのドキュメントで見つけることができる全てのヒントの目次
3. IBM 1000-90デバイスの基本機能を使うにあたってのヒント。 IBM 1000-90のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。IBM 1000-90に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるIBM 1000-90のメーカー/サービスへの連絡先に関する情報。

IBM 1000-90についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもIBM 1000-90の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがIBM 1000-90で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)