    LN-35 C V/CC SEMIA UTOMA TIC WIRE FEEDER OPERA TOR’S MANUAL IM812-A January, 2005 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thought- ful operation on your part. DO NOT INSTALL, OPERATE OR REPAIR THIS EQUIPM ...

  • Lincoln Electric IM812-A - page 2

    FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors. ________________________________________________ ...

  • Lincoln Electric IM812-A - page 3

    ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistant material to protect your skin ...

  • Lincoln Electric IM812-A - page 4

    FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations. 8.c. Ground the equipment in accordance with the U.S. National Electrical C ...

  • Lincoln Electric IM812-A - page 5

    iv SAFETY iv Mar. ‘93 PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L’Arc 1. Protegez-vous contre la secousse électrique: a. Les ...

  • Lincoln Electric IM812-A - page 6

    v v Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it handy for quick reference. Pay ...

  • Lincoln Electric IM812-A - page 7

    vi vi T ABLE OF CONTENTS Page INSTALLATION SECTION ......................................................................................................................A Technical Specifications .....................................................................................................................A-1 Safety Precautions .............. ...

  • Lincoln Electric IM812-A - page 8

    A-1 INST ALLA TION LN-35 A-1 TEMPERA TURE RANGE OPERA TION: - 40 o C to +40 o C (- 40 o F to +104 o F) STORAGE: - 40 o C to +85 o C (- 40 o F to +185 o F) OPERA TING ARC VOL T AGE Constant Voltage (CV) or 15-40 VDC (110VDC Maximum OCV) Constant Current (CC) RA TED CURRENT Rated current 500 Amps 60% Duty Cycle WIRE SPEED RANGE 50 – 500 Inches Per ...

  • Lincoln Electric IM812-A - page 9

    A-2 INST ALLA TION LN-35 A-2 ELECTRIC SHOCK can kill. • Do not operate with covers removed. • Turn off power source before installing or servicing. • Do not touch electrically hot parts. • Turn the input power to the welding power source off at the fuse box before working in the terminal strip. • Only qualified personnel should install, u ...

  • Lincoln Electric IM812-A - page 10

    A-3 INST ALLA TION LN-35 A-3 c. Set ELECTRODE POLARITY switch to constant voltage polarity required by electrode. d. Set toggle switch to “Constant Voltage” and set the Constant Voltage Control on welder and the portable field control on #5 for initial start. SA-200, —250 OR SAE-300, —400 (WITH CV ADAPTER) a. For electrode negative welding, ...

  • Lincoln Electric IM812-A - page 11

    A-4 INST ALLA TION LN-35 A-4 WELD CABLE CONNECTION The size of the electrode cable and work cable must be sufficient for the maximum weld current and total cable length to be used. Refer to table A.1. TABLE A.1 Total Cable Length Weld Current 60% Duty Cycle 50’-100’ 100’-150’ 150’-200’ 200’-250’ 200Amps 2 AWG 2 AWG 1 AWG 1/0 300Amps ...

  • Lincoln Electric IM812-A - page 12

    B-1 OPERA TION LN-35 B-1 ELECTRIC SHOCK can kill. • Do not touch electrically live part or electrode with skin or wet clothing. • Insulate yourself from work and ground. • Always wear dry insulat- ing gloves. ARC RAYS can burn. • Wear eye, ear and body protection. ------------------------------------------------------------------ FUMES AND ...

  • Lincoln Electric IM812-A - page 13

    B-2 OPERA TION B-2 LN-35 TO MOUNT A 50 OR 60 LB COIL: 1. To remove the wire reel from its shaft. 2. Lay the reel flat on the floor. Loosen the spinner nut and remove the cover plate. See Figure B.1. 3 . Place the coil of electrode on the reel so it unwinds as the reel rotates clockwise. DO NOT cut the tie wires at this time. 4. Be sure the coil is ...

  • Lincoln Electric IM812-A - page 14

    B-3 OPERA TION B-3 e. Press the gun trigger and push the electrode until it just enters the drive roll. When inching with gun trigger, the electrode and drive mechanism are always “hot” to work and ground. --------------------------------------------------------------------- f. Inch the electrode through the gun. IDLE ROLL PRESSURE SETTING The ...

  • Lincoln Electric IM812-A - page 15

    B-4 OPERA TION B-4 LN-35 PRESETTING WIRE FEED SPEED The LN-35 permits accurate presetting of the desired wire feed speed, before welding, in both CV and CC wire feed modes. SETTING CONSTANT WIRE FEED SPEED ( C V MODE) a. Set Wire Feed Mode switch to CV position. b . Set Wire Feed dial to the desired wire feed speed on the selected calibrated dial r ...

  • Lincoln Electric IM812-A - page 16

    B-5 OPERA TION B-5 MAKING A WELD SETUP a. Connect work cable to metal to be welded. Work cable must make good electrical contact to the work. The work must also be grounded as stated in “Arc Welding Safety Precautions.” b. Check that the LN-35 is properly connected to the power source for the polarity and process to be used, and appropriate pow ...

  • Lincoln Electric IM812-A - page 17

    B-6 OPERA TION B-6 a . Cut the electrode within approximately 3/8”(9.5mm) of the end of the contact tip for solid wire and within approximately 3/4”(19.1mm) of the extension guide for cored wire. b. Position electrode over joint. End of electrode should be slightly off the work. c . Lower welding helmet, close gun trigger, and begin welding. Ho ...

  • Lincoln Electric IM812-A - page 18

    B-7 OPERA TION B-7 CC (formerly VV) power sources, on the other hand, permit the arc voltage to decrease with increases in welding current. The output characteristics of these power sources can range from a “drooping slope,” which provide minor arc voltage changes with weld current variations, to “steep slope” which provide broad voltage ch ...

  • Lincoln Electric IM812-A - page 19

    D-1 MAINTENANCE D-1 LN-35 SAFETY PRECAUTIONS Have qualified personnel do the maintenance work. Turn the engine off before working inside the machine. In some cases, it may be necessary to remove safety guards to perform required maintenance. Remove guards only when necessary and replace them when the maintenance requiring their removal is complete. ...

  • Lincoln Electric IM812-A - page 20

    D-2 MAINTENANCE D-2 ADJUSTING SPEED SENSOR MODULE The LN-35 Speed Sensor Module is a three lead Hall Effect switch device encased in an externally threaded housing which is screwed into a mounting plate on the motor side of the wire drive gearbox. Proper positioning of this module is critical to proper operation of the LN-35 wire feed speed control ...

  • Lincoln Electric IM812-A - page 21

    E-1 TROUBLESHOOTING E-1 LN-35 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION This Troubleshooting Guide is provided to help you locate and repair possible m ...

  • Lincoln Electric IM812-A - page 22

    E-2 TROUBLESHOOTING E-2 LN-35 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION PROBLEMS (SYMPTOM ...

  • Lincoln Electric IM812-A - page 23

    E-3 TROUBLESHOOTING E-3 LN-35 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION PROBLEMS (SYMPTOM ...

  • Lincoln Electric IM812-A - page 24

    F-1 DIAGRAMS F-1 LN-35 632 633 631 10KW R1 WIRE SPEED CONTROL RHEOSTAT S3 S1 TO WORK CABL E BLACK POS 667 621 NEG A B C D E 622A 500A J5 TRIGGER CONNECTOR 7 * * J3 J14 3 2 1 4 2 1 3 4 621 500A 667 622A } } * * J2 J1 3 6 1 4 10 8 11 2 9 509 632 523 522 633 523 524 631 BLACK BLUE RED 524 523 509 V V CV WHI T E 539 BLACK 541 BLACK RED BLUE HALL EFFECT ...

  • Lincoln Electric IM812-A - page 25

    NOTES LN-35 ...

  • Lincoln Electric IM812-A - page 26

    W ARNING AV I S O D E PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES. SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL F ABRICANTE P ARA ...

  • Lincoln Electric IM812-A - page 27

    W ARNING AV I S O D E PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE P ARA ESTE EQUIP AMENTO E AS PAR TES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR. ● Keep your head out of fumes. ● Use ventilation or exhaust to remove fumes ...

  • Lincoln Electric IM812-A - page 28

    • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com • World's Leader in Welding and Cutting Products • ...

メーカー Lincoln Electric カテゴリー Welder

Lincoln Electric IM812-Aのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- IM812-Aの取扱説明書
- Lincoln Electricの製品カード
- パンフレット
- またはLincoln Electric IM812-Aの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Lincoln Electric IM812-Aの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Lincoln Electric IM812-Aの取り付け説明書、サービスマニュアル、簡易説明書、またはLincoln Electric IM812-Aのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Lincoln Electric IM812-Aの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Lincoln Electric IM812-Aデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがLincoln Electric IM812-Aを使用するのを助ける技術的文書のことです。説明書は通常、全てのLincoln Electric IM812-Aユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Lincoln Electricの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Lincoln Electric IM812-Aの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははLincoln Electric IM812-Aの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Lincoln Electric IM812-Aに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Lincoln Electric IM812-Aデバイスの基本機能を使うにあたってのヒント。 Lincoln Electric IM812-Aのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Lincoln Electric IM812-Aに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるLincoln Electric IM812-Aのメーカー/サービスへの連絡先に関する情報。

Lincoln Electric IM812-Aについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもLincoln Electric IM812-Aの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがLincoln Electric IM812-Aで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)