Pelco C1506Mの取扱説明書

12ページ 0.18 mb
ダウンロード

ページに移動 of 12

Summary
  • Pelco C1506M - page 1

    ® Installation/Operation IRD/ERD2000 Series Receiver C1506M (3/00) Pelco • 300 W . Pontiac Way , Clovis • CA 93612-5699 USA • Pelco Online @ www.pelco.com In North America and Canada: T el (800) 289-9100 • F AX (800) 289-9150 • DataFAX (800) 289-9108 International Customers: T el +1(559) 292-1981 • F AX +1(559) 348-1 120 • DataFAX +1 ...

  • Pelco C1506M - page 2

    [ 2 ] Pelco Manual C1506M (3/00) Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should only be done by qualified service personnel and conform to all local codes. 2. Unless the unit is specifically marked as a NEMA T ype 3, 3R, 3S, 4, 4X ,6 or 6P enclosure, it i s de - signed ...

  • Pelco C1506M - page 3

    Pelco Manual C1506M (3/00) [ 3 ] DESCRIPTION The IRD/ERD2000 Series Receiver operates Pelco’s fixed speed pan/tilts and domes. The receiver works with standard and extended Coaxitron ® controllers, including the CM6700/7500/8500/ 9500, KBD9000, MPT9000/9008/9500, and MX4000. With Coaxitron control, pan/tilt and lens control sig- nals are transmi ...

  • Pelco C1506M - page 4

    [ 4 ] Pelco Manual C1506M (3/00) ERD2200 WIRING ERD2200 Power Connections ENCLOSURE POWER OUT L L N N 115V 230V 115V POWER SELECTOR SWITCH GROUND STUD POWER TERMINALS MAIN FUSE ENCLOSURE FUSE MAIN POWER IN 1. Fuses are installed for 1 15 V AC operation. For 230 V AC operation, install the appropriate fuses (supplied). 2. Set the power selector swit ...

  • Pelco C1506M - page 5

    Pelco Manual C1506M (3/00) [ 5 ] 6. Connect the pan/tilt controls (up, down, left, right, and common). 7. Connect the camera power. If your camera uses 24 V AC, connect the camera to the CAM PWR connector on the front of the re- ceiver . The camera’s power must not exceed 5 vA. If your camera uses 1 15 or 230 VAC, connect the camera’ s power le ...

  • Pelco C1506M - page 6

    [ 6 ] Pelco Manual C1506M (3/00) IRD2024 WIRING Front View of Receiver 24V AC P AN/TILT CAM PWR I F Z C LENS AUX1 AUX2 5V CN N C O PWR CX IN OUT VIDEO TLC CC ~ + Rear View of Receiver 1. Connect power to the 24 V AC INPUT connector on the rear of the receiver . The receiver’s power re- quirement is a maximum of 5 vA, not including the camera and ...

  • Pelco C1506M - page 7

    Pelco Manual C1506M (3/00) [ 7 ] OPERA TION When power is applied to the receiver , the green PWR LED on the receiver lights. Whenever the receiver gets a valid Coaxitron control signal, the green CX LED blinks. Random/Auto Scanning Operation of random and auto scanning depends on whether your transmitter/controller is communicating with the IRD200 ...

  • Pelco C1506M - page 8

    [ 8 ] Pelco Manual C1506M (3/00) FUSE REPLACEMENT IRD2024 Lens/Auxiliary Fuse – A 500 mA fuse protects the LENS and AUX 1 outputs. Remove the cover of the receiver to check the fuse. ERD2200 Main Fuse – The main fuse protects the pan/tilt output when 24 V AC pan/tilt operation is selected. It also protects the 24 V AC camera output. Refer to th ...

  • Pelco C1506M - page 9

    Pelco Manual C1506M (3/00) [ 9 ] Wire Gauge T able A 24 V AC Wiring Distances T able The following are the recommended maximum wire distances (transformer to load) for 24 V AC applica- tions and are calculated with a 10-percent voltage drop. (T en percent is generally the maximum allowable voltage drop for AC-powered devices.) Distances are calcula ...

  • Pelco C1506M - page 10

    [ 10 ] Pelco Manual C1506M (3/00) SPECIFICA TIONS ERD2200 ELECTRICAL Input V oltage: 1 15/230 VAC, 50/60 Hz Output V oltage Camera: 24 V AC (or 115/230 V AC if using enclosure power) Lens: 8 VDC Pan/Tilt: 24/1 15/230 V AC Enclosure: 1 15/230 VAC Power Consumption Receiver: 5 vA maximum Pan/Tilt and Camera: 48 vA maximum at 24 V AC (includes 5 vA ma ...

  • Pelco C1506M - page 11

    Pelco Manual C1506M (3/00) [ 11 ] ...

  • Pelco C1506M - page 12

    WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Three years on Genex ® Series (multiplexers, server, and keyboard). • Two years on cameras and all standard motorized or fixed ...

メーカー Pelco カテゴリー Car Satellite TV System

Pelco C1506Mのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- C1506Mの取扱説明書
- Pelcoの製品カード
- パンフレット
- またはPelco C1506Mの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Pelco C1506Mの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Pelco C1506Mの取り付け説明書、サービスマニュアル、簡易説明書、またはPelco C1506Mのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Pelco C1506Mの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Pelco C1506Mデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがPelco C1506Mを使用するのを助ける技術的文書のことです。説明書は通常、全てのPelco C1506Mユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Pelcoの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Pelco C1506Mの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははPelco C1506Mの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Pelco C1506Mに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Pelco C1506Mデバイスの基本機能を使うにあたってのヒント。 Pelco C1506Mのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Pelco C1506Mに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるPelco C1506Mのメーカー/サービスへの連絡先に関する情報。

Pelco C1506Mについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもPelco C1506Mの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがPelco C1506Mで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)