APC 1000XLの取扱説明書

18ページ 0.52 mb
ダウンロード

ページに移動 of 18

Summary
  • APC 1000XL - page 1

    990-1062A 11/01 User’s Manual English APC Smart-UPS ® 1000VA /1500V A 230VAC /120VAC/100VA C 750XL/1000XL 230VAC/120VA C Tower Uninterr uptible Pow er Supply ...

  • APC 1000XL - page 2

    ...

  • APC 1000XL - page 3

    1 Introduction American Po w er Conversion Corpo ration (APC) is the leading national and international manufac- turer of state-of- the-art un interru ptible pow er suppl ies, redundan t swi tches, power m anagement soft- ware, an d related equi pment. APC produ cts protect h ardware, sof tware, and data f rom pow er distur- banc es in b usine ss a ...

  • APC 1000XL - page 4

    2 Connecting Equipment and Power to the UPS S MART - UPS R EAR P ANEL 230V M ODELS 120 V/100V M ODELS 1. Plug in th e battery con nector  . 2. Connect equi pment to the UPS. Note: Do not connect a laser printer to the UPS. A laser printer d raws signifi cantly m ore power than other type s of equ ipmen t and may overl oad the UPS. 3. Add any opt ...

  • APC 1000XL - page 5

    3 B ASIC C ONNE CTORS Serial Port USB Port Power management s oftware and interface k its can be used wi th th e U PS. Use only interfa ce kits supplied or approv ed by APC. Use the APC supplied cable to connect to the Serial Port. DO NOT use a standard serial interface cable since it is incompatible with the UPS connector. Both Serial a nd USB Por ...

  • APC 1000XL - page 6

    4 2: O PERA TION S MART - UPS F RONT P ANEL Power On Power Off Load Battery Charge Online The online LED illuminates when the UPS is supplying utilit y power to the con- nected equipment. If the LED is not lit, the UPS is eit her not turned ON, or is sup- plying battery power. AVR Tri m This LED illuminates to i ndicate the UPS is compensating for ...

  • APC 1000XL - page 7

    5 AVR Boost This LED illuminates to indicate the UPS is compensating for a low utility voltage. On Battery When the on batter y power LED is lit th e UPS is supp lying battery power to the con nected equipment. Wh en on battery, the UPS sounds an alarm—four beeps ev ery 30 seconds . Overload The LED illuminates and the UPS emits a sustained alar ...

  • APC 1000XL - page 8

    6 3: U SER C ONFIGU RA BLE I TEM S N OTE : S ETTINGS ARE MADE THROUGH SUPPLIED P OWER C HUTE S OFTWARE OR OP TIONAL S MAR T S LOT ACCESSORY CARDS . F UNCTION F ACTORY D EFAULT U SER S EL ECTABLE C HOICES D ESCRIPTION Automa tic Self -Test Every 14 day s (336 hours) Every 7 days (168 hours) , On Startup Only, No Self- Test This func tion sets the in ...

  • APC 1000XL - page 9

    7 N OTE : S ETTINGS ARE MADE THROUGH SUPPLIED P OWER C HUTE S OFTWARE OR OP TIONAL S MAR T S LOT ACCESSORY CARDS . F UNCTION F ACTORY D EFAULT U SER S EL ECTABLE C HOICES D ESCRIPTION Low Battery Warning . PowerChute in terface softw are pr ovides a uto- matic, unatte nded shut- down w hen appr oxi- mately two m inutes (by defa ult) of ba ttery ope ...

  • APC 1000XL - page 10

    8 4: S TO R AG E , M A INT ENA NCE , A ND T R A NSPO RTING Storage Store the UPS covered and positioned as for proper functioning, in a cool, dry location, with the bat- teries fully charged. At -15 t o +30 ° C (+5 to + 86 ° F), charg e the UPS battery every six months. At +30 t o +45 ° C (+86 to + 113 ° F), charge th e UPS battery every three ...

  • APC 1000XL - page 11

    9 1500VA Model Step 3 Pull the battery module out of the compartment until t he back of the m odule is flush with th e outer edg es of the U PS. Disconn ect the battery conn ector. 1000VA Model Step 3 Disconnect the batter y cable termin als before re moving t he batt er y module fr om the UP S. Note: The red cable conn ects to the red color- coded ...

  • APC 1000XL - page 12

    10 R EPL ACING THE B ATTERY M ODULE To replace the battery module, reverse th e directions above for Removin g the Front Bezel and Bat- tery M odule . Disconnecting the Battery for Transport Always DISCONNEC T THE BATT ERY before shipp ing in co m pliance w ith U.S. Departm ent of Transp ortation (DOT) regu lations. The battery m ay remain in the U ...

  • APC 1000XL - page 13

    11 5: T ROUBLESHOOTING Use the chart belo w to solve minor S mart-UPS installation and o peration problems. Refer to the APC web site, www.apc.com , for assistance with com plex UPS problems. P ROBLEM AND P OSSI BLE C AUSE S OLUTION UPS WILL NOT TURN ON Batter y not conn ected prop - erly. Check that the battery conn ector (rear pan el) is fully en ...

  • APC 1000XL - page 14

    12 P ROBLEM AND P OSSI BLE C AUSE S OLUTION T HE OVERLOAD LED IS LIT AND THE UPS EMITS A SUSTAINED ALARM TONE The UPS is overloaded. The conn ected equi pment exceed s the sp ecified “maximu m load” as de- fine d in Spec ifications at the APC w eb site, w ww .apc.com . The alarm remai ns on un til the overload i s removed. Discon nect nonessen ...

  • APC 1000XL - page 15

    13 P ROBLEM AND P OSSIBLE C AUSE S OLUTION UTILITY CIRCUIT BREAKER T RIPS Utility c ircuit breake r trips during norma l operatio n. 100V mo dels: In order to operate at the f ull VA rating of the 1500VA produ ct, the sup plied 15A pl ug must be replaced with a 20 A plug. This change mus t be perf orme d by qualifie d serv ice pe rsonnel. UPS OPERA ...

  • APC 1000XL - page 16

    14 Service If the UPS requires s ervice do not return it to the dealer. Ins tead, follow these steps: 1. Revi ew the problem s discussed in the Tr oubleshooti ng section of this manual to eliminate com- mon probl ems . 2. If the problem persists, contact APC Custom er Service through the APC web site, www.apc.com/su pport .  Note the m odel num ...

  • APC 1000XL - page 17

    15 6: R EGULA TOR Y A ND W AR R AN T Y I NFORMA T ION Regulatory Agency Approvals and Radio Frequency Warnings 230V MOD ELS This is a Class A pro duct. I n a domestic e nviro nment this product m ay cause ra dio int erferenc e, in which cas e the u ser ma y be requ ired to tak e correct ive a c- tions . 120V MOD ELS This e qui pment has bee n teste ...

  • APC 1000XL - page 18

    16 Declaration of Conformity Limited Warranty American Power Conversion (APC) warrants it s products to be free from defects in materials and workmanshi p for a period of two years from th e date of pu rchase. Its obli gation und er this warranty is lim ited to repairin g or replac ing, at its own sole o p- tion, any such defecti ve produ cts. To o ...

メーカー APC カテゴリー Power Supply

APC 1000XLのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 1000XLの取扱説明書
- APCの製品カード
- パンフレット
- またはAPC 1000XLの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、APC 1000XLの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、APC 1000XLの取り付け説明書、サービスマニュアル、簡易説明書、またはAPC 1000XLのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、APC 1000XLの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

APC 1000XLデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAPC 1000XLを使用するのを助ける技術的文書のことです。説明書は通常、全てのAPC 1000XLユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

APCの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. APC 1000XLの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAPC 1000XLの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。APC 1000XLに関してこのドキュメントで見つけることができる全てのヒントの目次
3. APC 1000XLデバイスの基本機能を使うにあたってのヒント。 APC 1000XLのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。APC 1000XLに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAPC 1000XLのメーカー/サービスへの連絡先に関する情報。

APC 1000XLについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAPC 1000XLの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAPC 1000XLで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)