Datalogic CBX500の取扱説明書

15ページ 関係なし
ダウンロード

ページに移動 of 15

Summary
  • Datalogic CBX500 - page 1

    CBX500 INSTALLATION MANUAL Figure A Indicator LEDs 1 Cove r Screw s (4) 2 Compression Connectors ( 5) 4 25-pin Device Connect or 5 Fieldbus Interf ace Panel 3 5 1 2 4 3 ...

  • Datalogic CBX500 - page 2

    CBX500 INSTALLATION MANUAL 2 Figure B Power switc h (ON/OFF) 1 2 Device Chassis Grounding Selector 3 Mounting Holes (2) 5 4 I/O Extension Module Connector Backup Module Connector 6 Indicator LEDs RS485 Termination Resistance Switch 7 ID-NET™ Termination Resistance Switch 8 Auxiliary Por t Connector 9 IP65 Fieldbus Module Connector 10 Standard Fie ...

  • Datalogic CBX500 - page 3

    CBX500 INSTALLATION MANUAL 3 UPDATES AND LANGUAGE AVAILABILITY UK/US The latest drivers and documentatio n updates for this product are availabl e on Internet. Log on to: www.automation.datalogic.com I Su Internet sono disponibili le versio ni aggiornate di driver e documentazione di questo pr odotto. Questo manuale è disponibile anche nell a vers ...

  • Datalogic CBX500 - page 4

    CBX500 INSTALLATION MANUAL 4 DESCRIPTION The CBX500 is a conn ection box which can be used a s an accessory to facilitate system connections for installation and device replac ement of several Datalogic family reading dev ices. System cabling is made throug h spring clamp terminal blocks i nside the CBX500 while the reading dev ice is connected to ...

  • Datalogic CBX500 - page 5

    CBX500 INSTALLATION MANUAL 5 SUPPORTED READING DEVICE MODELS The CBX500 can be directly connected to the following re ade rs through the 25-pin connecto r illustrated in Fi gure A. Linear Scanners 2D Readers DS2100N DS2400N DS4800 DS6300 MAT RIX -10 00 M ATRIX-2000 DS6400 DX6400 DS8100A DX8200A MATRIX 400 NOTE CBX500 is backward compatible with DS4 ...

  • Datalogic CBX500 - page 6

    CBX500 INSTALLATION MANUAL 6 MECHANICAL INSTALLATION CBX500 can be mounted to various wooden o r plastic surfac es using the tw o self-threading screw s (3.9 x 45 mm) and washers p rovided in the package. Mounting to other surfaces such as concrete walls or metallic panels requires user-supplied parts (scre ws, screw anchors, nuts, etc). A mounting ...

  • Datalogic CBX500 - page 7

    CBX500 INSTALLATION MANUAL 7 through the utility program (s ee the reading device Insta llation Manual for more details). T he reading device auxiliary interfa ce signals are also availabl e on the internal spring clamp c onnectors. After making system cabling and s witch settings, connect the reading device to the 25-pin connector on the CBX500 ho ...

  • Datalogic CBX500 - page 8

    CBX500 INSTALLATION MANUAL 8 SYSTEM WIRING The connection and wiring procedure for CBX500 is descri bed as follows: 1) Open the CBX500 by unscrewing the four cover scre ws. 2) Verify that the CBX500 power switch is off (see Figure 3). 3) Unscrew the compression connectors and pass all the s ystem cables through them into the CBX500 h ousing. 4) To ...

  • Datalogic CBX500 - page 9

    CBX500 INSTALLATION MANUAL 9 PINOUT Pinouts Group Name Function Vdc Power S upply Input Voltage + GN D Power Suppl y Input Volta ge - Input Power Eart h Protection Earth Ground +V Power Source – Ex ternal Trigge r I1A External Trigger A (pola rity insensitive) I1B External Trigger B (pola rity insensitive) External Trigger Input -V Power Referenc ...

  • Datalogic CBX500 - page 10

    CBX500 INSTALLATION MANUAL 10 POWER SOURCE JUMPER SETTINGS For most applications input power is provided through t he dedic ated spring clamp connectors inside the CBX500. However CB X500 may acc ept power fro m the connect ed reading device thro ugh the 25- pin connector. T his is useful, for example, to pass po wer to connected acce ssories such ...

  • Datalogic CBX500 - page 11

    CBX500 INSTALLATION MANUAL 11 9-PIN READING DEVICE AUXIL IARY SERIAL INTERFACE The reading device au xiliary serial interface availab le on the internal CBX500 9- pin connector can be used eithe r for configuration or for data monitoring. Connections can be made to a PC or Lapt op using a straight through cable or a USB-RS232 conv erter. The detail ...

  • Datalogic CBX500 - page 12

    CBX500 INSTALLATION MANUAL 12 RS485 HD ON OFF Figure 11 – RS485 HD Terminati on Resistance Sw itch The RS485 HD termination r esistance switch enables or d is ables the inse rtion of the bus termination resistor for RS485 Half Duplex Multidrop applicati ons. CAUTION In Multiplexer applications the termination resi stor must be e nabled ONLY on th ...

  • Datalogic CBX500 - page 13

    CBX500 INSTALLATION MANUAL 13 TECHNICAL FEATURES ELECTRICAL FEATURES Supply Voltage 10 to 30 Vdc* Consumption 0.8 – 0.5 A Limited Current Consumption CBX + reading device cons umption (see related manual) 2.5 A USER INTERFACE LED In dic at ors Power On/Polarity Error (blue/r ed) Trigger (y ellow) IN2 (green) OUT1 (yellow) OUT2 (green) PHYSICAL FE ...

  • Datalogic CBX500 - page 14

    CBX500 INSTALLATION MANUAL 14 FCC COMPLIANCE Modifications or changes to this equipm ent without the expressed written approval of Datal ogic could void the authority to use the equipm ent. This device complies with PA RT 15 of the FCC Rules. Operation is subject to the following t wo conditions: (1) This device may not cause harmful in terfe rence ...

  • Datalogic CBX500 - page 15

    DECLARATION OF CONFORMITY 08 Datalogic A utomation S.r.l. Via S. Vitalino 13 40012 - Lippo di Calderara Bologna - Italy dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el CBX500 connection box modul ar; e tutti i suoi modelli and all its models et tous ses modèles und seine Modelle y todos sus modelos sono c ...

メーカー Datalogic カテゴリー Barcode readers

Datalogic CBX500のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- CBX500の取扱説明書
- Datalogicの製品カード
- パンフレット
- またはDatalogic CBX500の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Datalogic CBX500の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Datalogic CBX500の取り付け説明書、サービスマニュアル、簡易説明書、またはDatalogic CBX500のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Datalogic CBX500の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Datalogic CBX500デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがDatalogic CBX500を使用するのを助ける技術的文書のことです。説明書は通常、全てのDatalogic CBX500ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Datalogicの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Datalogic CBX500の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははDatalogic CBX500の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Datalogic CBX500に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Datalogic CBX500デバイスの基本機能を使うにあたってのヒント。 Datalogic CBX500のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Datalogic CBX500に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるDatalogic CBX500のメーカー/サービスへの連絡先に関する情報。

Datalogic CBX500についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもDatalogic CBX500の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがDatalogic CBX500で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)