FMI MF42OPEの取扱説明書

28ページ 6.54 mb
ダウンロード

ページに移動 of 28

Summary
  • FMI MF42OPE - page 1

    For more information, visit www .fmiproducts.com VENTED GAS LOG APPLIANCE OWNER’S OPERA TION AND INST ALLA TION MANU AL WHEN USED AS AN OUTDOOR APPLIANCE WHEN USED AS INDOOR VENTED APPLIANCE REMO TE-READ y LOG SET AND BURNER Sy STEM MODELS MF42ONE, MF42OPE, MF48ONE, MF48OPE MF42 MODELS MA Y BE USED WITH LMF42-SC LOGS ONL Y MF48 MODELS MA Y BE USE ...

  • FMI MF42OPE - page 2

    www .fmipr oducts.com 125636-01A 2 SAFETy DAN GER: Car bon m ono xide poi son ing m ay lead to death! Carbon Monoxide Poisoning: Early signs of carbon mon- oxide poisoning resemble the u, with headaches, dizziness or nausea. If you have these signs, the replace may not be working properly. Get fresh air at once! Have replace ser - viced. S ...

  • FMI MF42OPE - page 3

    www .fmipr oducts.com 125636-01A 3 SAFETy Continued 1. This appliance is only for use with the type of gas indic ated on the rat ing plate. This ap plianc e is not convert ible for use with other gases. 2. Do not place propane/LP supply tank(s) inside any struc - ture. Locate propane/LP supply tank(s) outdoors (propane/ LP units only). 3. If you sm ...

  • FMI MF42OPE - page 4

    www .fmipr oducts.com 125636-01A 4 LOCAL CODES Install and use appliance with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANSI Z223.1/NFP A 54 *. *Available from: American National Standards Institute, Inc. 1430 Broadway New Y ork, NY 10018 National Fire Protection Association, ...

  • FMI MF42OPE - page 5

    www .fmipr oducts.com 125636-01A 5 LOG SIZING REqUIREMENTS Log Size Minimum Firebox Size Height Depth Front Width Rear* Width 42" 29" 15.5" 39" 26.75" 48" 29" 20" 47" 33" Carefully follow the instructions below . This will ensure safe installation into a masonry , UL127-listed manufactured re - p ...

  • FMI MF42OPE - page 6

    www .fmipr oducts.com 125636-01A 6 NOTICE: Surface temperatures of adjacent walls and mantels become hot during opera - tio n. Wall s and man te ls abov e th e re box may bec ome ho t to the tou ch . If ins ta ll ed p rop er ly , th es e tem pera tu res me et the re qu ir em en t of th e nat ional prod uc t sta nd ard . Fol lo w all min imu m cl ...

  • FMI MF42OPE - page 7

    www .fmipr oducts.com 125636-01A 7 INST ALLA TION Continued INST ALLING APPLIANCE BASE ASSEMBL y Area of V arious Standard Round Flues Diameter Area 5" 20 sq. inches 6" 29 sq. inches 7" 39 sq. inches 8" 51 sq. inches Chimney Height Minimum Permanent Flue Opening 6' to 15' 39 sq. inches 15' to 30' 29 sq. inche ...

  • FMI MF42OPE - page 8

    www .fmipr oducts.com 125636-01A 8 optional equipment shutoff valve from your dealer . For propane/LP units, the installer must supply an external regulator . The external regulator will reduce incoming gas pressure. Y ou must reduce incoming gas pressure to be - tween 1 1" and 14" of water . If you do not reduce incoming gas pressure , a ...

  • FMI MF42OPE - page 9

    www .fmipr oducts.com 125636-01A 9 INST ALLA TION Continued We recommend that you install a sediment trap in supply line as shown in Figure 12. Locate sediment trap where it is within reach for cle aning. Install in pip ing system between fuel supply and appliance. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap t ...

  • FMI MF42OPE - page 10

    www .fmipr oducts.com 125636-01A 10 INST ALLING BA TTERIES IN HAND HELD REMOTE CONTROL AND BA TTERY P ACK Installing Batteries in Battery pack 1. Remove access cover on battery pack. 2. Install 4 AA batteries, included, into battery pack following positive and negative directions. 3. Replace access cover on battery pack. 4. Place battery pack next ...

  • FMI MF42OPE - page 11

    www .fmipr oducts.com 125636-01A 11 INST ALLA TION Continued Figure 17 - Installing Right Front Log Figure 17A - Installing Right Front Log, Top V iew Burner T ube Grate Finger Right Front Log (D-019 or D027) Round T ube Burner Grate Finger Figure 18 - Installing Back Left Log Figure 17B - Installing Right Front Log, T op View Figure 17C - Installi ...

  • FMI MF42OPE - page 12

    www .fmipr oducts.com 125636-01A 12 INST ALLA TION Continued Figure 18A - Installing Back Left Log Figure 18B - Installing Back Left Log (D-018) Rear V iew Figure 19 - Installing Front Left Log Grate Fingers Front Left Log (D-017 or D025) Burner T ube Log Notch Find the charred log (D-020). See Figures 20, 20A, and 4. 20B. The log has a slot in the ...

  • FMI MF42OPE - page 13

    www .fmipr oducts.com 125636-01A 13 INST ALLA TION Continued Find the middle split log (LMF42-SC: D-021 or LMF48-SC: 5. D028). See Figures 21 and 21A. The split side of the log faces forward. The log has a notch that ts around the bur ner tub e on the righ t side . The lef t si de of the bur ne r tube ts into the notch on the back side of thi ...

  • FMI MF42OPE - page 14

    www .fmipr oducts.com 125636-01A 14 INST ALLA TION Continued Figure 24 - Installing Back T op Log and Final Assembly Figure 24A - Installing Back Top Log, T op V iew Right Split Crossover Log (D-022) Back T op Log (D-023 or D029) Find the back top log (LMF-SC: D-023 or LMF48-SC: 8. D029).See Figures 24, and 24A. The left end of this log has a round ...

  • FMI MF42OPE - page 15

    www .fmipr oducts.com 125636-01A 15 OPERA TION Continued Figure 25 - Turning Equipment Shutof f Valve to the OFF Position MAIN IN OUT PILOT ADJ PILOT Equipment Shutoff V alve Incoming Gas Line GAS CONTROL MODULE Sy STEM REMOTE CONTROL FEA TURE The module has a built in remote control receiver that allows the user to program the remote transmitter a ...

  • FMI MF42OPE - page 16

    www .fmipr oducts.com 125636-01A 16 CLEANING AND MAINTENANCE Continued INSPECTING B URNERS Continued Figure 30 - Incorrect Burner Flame Pattern Dark Orange Flames CLEANING AND MAINTENANCE W ARNING: T urn off appliance and let cool before cleaning. CAUTION: Y ou must keep control areas, burners and cir culating air pas sageways of ap - pliance clean ...

  • FMI MF42OPE - page 17

    www .fmipr oducts.com 125636-01A 17 WIRING DIAGRAM Orange Orange Orange Re d Brow n Black Solenoid White Brow n Brow n Green Ignitor Pilot I S A UX AF-5000MOD AF-4000 AF-4000B/P Co ntrol Module Black Black Optional DC Battery Back-up Re d SWI SWI (GND) Black Re d HI/L O Main Black These wires are not used on this application ...

  • FMI MF42OPE - page 18

    www .fmipr oducts.com 125636-01A 18 TROUBLESHOO TING W ARNING: T urn off appliance and let cool before servicing. Only a qualied service person should service and repair appliance. Note: All troubleshooting items are listed in order of operation. POSSIBLE CAUSE 1. Ignitor electrod e not conn ected to ignitor cable 2. Ignitor cable pinched or wet ...

  • FMI MF42OPE - page 19

    www .fmipr oducts.com 125636-01A 19 POSSIBLE CAUSE 1. Manifold pressure is too low 2. Burner orice clogged 1. Burner orice is clogged or dam - aged 2. Damaged burner 1 . Residues from manufacturing processes and logs curing 1. Air in gas line 2. Air passageways on appliance blocked 3. Dirty or partially clogged burner orice. 1. When heated ...

  • FMI MF42OPE - page 20

    www .fmipr oducts.com 125636-01A 20 TROUBLESHOO TING Continued W ARNING: If you smell gas • Shut off gas supply . • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor ’ s phone. Follow the gas supplier ’ s instruc - tions. ? ...

  • FMI MF42OPE - page 21

    www .fmipr oducts.com 125636-01A 21 ACCESSORIES Purchas e these appl iance accessorie s from your local dealer . If they can not supply these accessories, call FMI PROD - UCTS, LLC at 1-866-328-4537 for referral information. Y ou can also write to the address listed on the back page of this manual. FIREPLACE HOOD Black - GA6050 Antique Brass - GA60 ...

  • FMI MF42OPE - page 22

    www .fmipr oducts.com 125636-01A 22 P ARTS REMOTE-READY CONTROL MODELS MF42ONE, MF42OPE, MF48ONE, MF48OPE 1 2 4 5 6 7 8 9 10 11 12 13 15 16 18 19 20 21 23 24 25 26 22 17 14 8 3 ...

  • FMI MF42OPE - page 23

    www .fmipr oducts.com 125636-01A 23 P ARTS REMOTE-READY MODELS MF42ONE, MF42OPE, MF48ONE, MF48OPE This list contains replaceable parts used in your appliance. When ordering parts, follow the instructions listed under Replace- ment Parts on page 25 of this manual. KEY NO. P ART NO. DESCRIPTION QTY . 1 125593-01 Burner Stainless MF • • • • 1 ...

  • FMI MF42OPE - page 24

    www .fmipr oducts.com 125636-01A 24 P ARTS LOG SETS FOR MODELS MF42ONE, MF42OPE, MF48ONE, MF48OPE This list contains replaceable parts used in your appliance. When ordering parts, follow the instructions listed under Replacement Parts on page 25 of this manual. Each log includes a reference number . The rst number indicates the order it is place ...

  • FMI MF42OPE - page 25

    www .fmipr oducts.com 125636-01A 25 REPLACEMENT P ARTS Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty . Contact authorized dealers of this product. If they can’t supply original replacement part(s), call FMI PRODUCTS, LLC at 1-866-328-4537. When calling, have ready: • your n ...

  • FMI MF42OPE - page 26

    www .fmipr oducts.com 125636-01A 26 _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ________________________________________ ...

  • FMI MF42OPE - page 27

    www .fmipr oducts.com 125636-01A 27 _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ________________________________________ ...

  • FMI MF42OPE - page 28

    125636-01 Rev . A 10/10 WARRANTy kEEP THIS WARRANTy FMI PRODUCTS, LL C LIMITED WARRANTIES New Products Standard Warranty: F M I P R O DU C TS , LL C w ar r an t s t h i s n e w p r od u ct a n d a n y p a rt s th e re o f t o b e f r e e f r om d ef e ct s i n m a te r ia l a nd workmanship for a period of four (4) years from the date of rst pur ...

メーカー FMI カテゴリー Outdoor Gas Burner

FMI MF42OPEのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- MF42OPEの取扱説明書
- FMIの製品カード
- パンフレット
- またはFMI MF42OPEの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、FMI MF42OPEの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、FMI MF42OPEの取り付け説明書、サービスマニュアル、簡易説明書、またはFMI MF42OPEのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、FMI MF42OPEの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

FMI MF42OPEデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがFMI MF42OPEを使用するのを助ける技術的文書のことです。説明書は通常、全てのFMI MF42OPEユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

FMIの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. FMI MF42OPEの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははFMI MF42OPEの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。FMI MF42OPEに関してこのドキュメントで見つけることができる全てのヒントの目次
3. FMI MF42OPEデバイスの基本機能を使うにあたってのヒント。 FMI MF42OPEのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。FMI MF42OPEに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるFMI MF42OPEのメーカー/サービスへの連絡先に関する情報。

FMI MF42OPEについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもFMI MF42OPEの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがFMI MF42OPEで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)