  • Trane TUD2D120B9V5VB - page 1

    UPFLO W/HORIZONT AL 2-ST A GE, V ARIABLE SPEED GAS-FIRED FURNA CE PUB. NO . 22-1650-13 XV 80 MODELS TUD2B060A9V3VB , TUD2B080A9V3VB TUD2C080A9V4VB , TUD2C080B9V4VB TUD2B100A9V3VB , TUD2C100A9V5VB TUD2C100B9V5VB , TUD2D120A9V5VB TUD2D120B9V5VB , TUD2D140A9V5VB © 2011 T rane T w o-Stage F anAssisted Comb ustionSystem ...

  • Trane TUD2D120B9V5VB - page 2

    2 22-1650-13 General Features © 2011 T rane NA TURAL GAS MODELS Central Heating furnace designs are cer- tified by the American Gas Association f or both natural and L.P . gas. Limit setting and rating data were estab lished and approv ed under standar t rating condi- tions using American National Standards Instirute standards. SAFE OPERA TION Th ...

  • Trane TUD2D120B9V5VB - page 3

    3 22-1650-13 Featur e Summar y Featur es and Benefits Standard Equipment Optional Equipment General Data TUD2B060A9V3VB TUD2B080A9V3VB TUD2C080A9V4VB TUD2C080B9V4VB TUD2B100A9V3VB TUD2C100A9V5VB TUD2C100B9V5VB TUD2D120A9V5VB TUD2D120B9V5VB TUD2D140A9V5VB Per formance Data Electric Data Field Wiring Diagrams Dimensions Contents 2 4 4 5 6 9 19 19 24 ...

  • Trane TUD2D120B9V5VB - page 4

    4 22-1650-13 XV80 ST AND ARD EQUIPMENT • Upow/Horizontaland • P owersupply115/1/60 • 2-stagegasvalv e • 2-speedventer • V ar iab lespeedblowermotor • SiliconNitridehotsurfaceigniterwith adaptive heat up • Integratedsolidstatecontrol • Attractiv ec ...

  • Trane TUD2D120B9V5VB - page 5

    5 22-1650-13 XV80 OPTIONAL EQUIPMENT Thermostat, Mechanical 2-Stage Heating/1-Stage Cooling ........................................................................................ T A YST A T241 [ ] Thermostat, Mechanical Heating Only With F an Switch ............................................................................................. BA ...

  • Trane TUD2D120B9V5VB - page 6

    6 DA T A SUBJECT T O CHANGE WITHOUT NOTICE 22-1650-13 MODEL TYPE RA TINGS 2 1st Stage Input BTUH 1st Stage Capacity BTUH (ICS) 3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3 T emp . rise (Min.-Max.) °F . BLO WER DRIVE Diameter - Width (In.) No . Used Speeds (No .) CFM vs. in. w .g. Motor HP R.P .M. V olts / Ph / Hz COMBUSTION F AN - T ype ...

  • Trane TUD2D120B9V5VB - page 7

    22-1650-13 DA T A SUBJECT TO CHANGE WITHOUT NOTICE 7 MODEL TYPE RA TINGS 2 1st Stage Input BTUH 1st Stage Capacity BTUH (ICS) 3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3 T emp . rise (Min.-Max.) °F . BLO WER DRIVE Diameter - Width (In.) No . Used Speeds (No .) CFM vs. in. w .g. Motor HP R.P .M. V olts / Ph / Hz COMBUSTION F AN - T ype D ...

  • Trane TUD2D120B9V5VB - page 8

    8 DA T A SUBJECT T O CHANGE WITHOUT NOTICE 22-1650-13 MODEL TYPE RA TINGS 2 1st Stage Input BTUH 1st Stage Capacity BTUH (ICS) 3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3 T emp . rise (Min.-Max.) °F . BLO WER DRIVE Diameter - Width (In.) No . Used Speeds (No .) CFM vs. in. w .g. Motor HP R.P .M. V olts / Ph / Hz COMBUSTION F AN - T ype ...

  • Trane TUD2D120B9V5VB - page 9

    22-1650-13 DA T A SUBJECT TO CHANGE WITHOUT NOTICE 9 *UD2B060A9V3VB FURNA CE COOLING AIRFLO W (CFM) AND POWER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER OUTDOOR UNIT SIZE (T ONS) AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW1 SW2 SW3 SW4 0.1 0.3 0.5 0.7 0.9 1.5 LOW (350 CFM/ T ON) ON ON OFF ON CFM W A TTS 499 50 537 80 ...

  • Trane TUD2D120B9V5VB - page 10

    10 DA T A SUBJECT T O CHANGE WITHOUT NOTICE 22-1650-13 *UD2B080A9V3VB FURNA CE COOLING AIRFLO W (CFM) AND POWER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER OUTDOOR UNIT SIZE (T ONS) AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 2.5 LOW (350 CFM/T ON) OFF ON OFF ON CFM W A TTS 880 120 ...

  • Trane TUD2D120B9V5VB - page 11

    22-1650-13 DA T A SUBJECT TO CHANGE WITHOUT NOTICE 11 *UD2C080A9V4VB FURNA CE HEA TING AIRFLOW (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 782 49 75 762 51 110 751 51 145 748 51 ...

  • Trane TUD2D120B9V5VB - page 12

    12 DA T A SUBJECT T O CHANGE WITHOUT NOTICE 22-1650-13 *UD2C080B9V4VB FURNA CE HEA TING AIRFLOW (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 974 49 133 968 49 285 949 50 202 925 ...

  • Trane TUD2D120B9V5VB - page 13

    22-1650-13 DA T A SUBJECT TO CHANGE WITHOUT NOTICE 13 *UD2B100A9V3VB FURNA CE HEA TING AIRFLO W (CFM) AND POWER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 751 64 86 796 61 132 817 59 175 832 58 ...

  • Trane TUD2D120B9V5VB - page 14

    14 DA T A SUBJECT T O CHANGE WITHOUT NOTICE 22-1650-13 *UD2C100A9V5VB FURNA CE HEA TING AIRFLO W (CFM) AND POWER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 900 53 100 890 54 130 870 55 175 850 ...

  • Trane TUD2D120B9V5VB - page 15

    22-1650-13 DA T A SUBJECT TO CHANGE WITHOUT NOTICE 15 *UD2C100B9V5VB FURNA CE HEA TING AIRFLO W (CFM) AND POWER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 953 50 93 944 50 146 936 51 193 908 52 ...

  • Trane TUD2D120B9V5VB - page 16

    16 DA T A SUBJECT T O CHANGE WITHOUT NOTICE 22-1650-13 *UD2D120A9V5VB FURNA CE HEA TING AIRFLOW (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW7 SW8 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 1007 57 114 1062 54 177 1084 53 285 106 ...

  • Trane TUD2D120B9V5VB - page 17

    22-1650-13 DA T A SUBJECT TO CHANGE WITHOUT NOTICE 17 *UD2D120B9V5VB FURNA CE HEA TING AIRFLOW (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE S4-3 S4-4 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 1050 45 99 1044 46 146 1035 46 208 100 ...

  • Trane TUD2D120B9V5VB - page 18

    18 DA T A SUBJECT T O CHANGE WITHOUT NOTICE 22-1650-13 *UD2D140A9V5VB FURNA CE HEA TING AIRFLO W (CFM) AND POWER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 1090 62 130 1100 61 175 1070 63 215 1 ...

  • Trane TUD2D120B9V5VB - page 19

    22-1650-13 DA T A SUBJECT TO CHANGE WITHOUT NOTICE 19 PRODUCT D A T A WIRING DIA GRAM F rom Dwg. D344249P02 ...

  • Trane TUD2D120B9V5VB - page 20

    20 DA T A SUBJECT T O CHANGE WITHOUT NOTICE 22-1650-13 PRODUCT D A T A SCHEMA TIC DIA GRAMS F rom Dwg. D344249P02 ...

  • Trane TUD2D120B9V5VB - page 21

    22-1650-13 DA T A SUBJECT TO CHANGE WITHOUT NOTICE 21 PRODUCT D A T A FIELD WIRING DIA GRAM FOR SINGLE ST A GE HEA TING ONL Y F rom Dwg. 21B341127 Rev . 0 F rom Dwg. 21B341126 Rev . 0 FIELD WIRING DIA GRAM FOR TW O ST A GE HEA TING TO 115 V 1 PH., 60 HZ., POWER SUPPL Y PER LOCAL CODES M M M M M M S S S S S S S S S S S S S S S S S S S S S S S S S S ...

  • Trane TUD2D120B9V5VB - page 22

    22 DA T A SUBJECT T O CHANGE WITHOUT NOTICE 22-1650-13 PRODUCT D A T A FIELD WIRING DIA GRAM FOR SINGLE ST A GE HEA TING WITH SINGLE ST A GE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) F rom Dwg. 21B341125 Rev . 1 F rom Dwg. 21B341124 Rev . 1 FIELD WIRING DIA GRAM FOR TWO ST A GE HEA TING WITH SINGLE ST A GE COOLING (OUTDOOR SECTION WITHOUT TRANS ...

  • Trane TUD2D120B9V5VB - page 23

    22-1650-13 DA T A SUBJECT TO CHANGE WITHOUT NOTICE 23 PRODUCT D A T A FIELD WIRING DIA GRAM FOR TWO ST A GE HEA TING WITH TW O ST A GE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) F rom Dwg. 21B341128 Rev . 0 TO 115 V 1 PH., 60 HZ., PO E S S S S S S S E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E ...

  • Trane TUD2D120B9V5VB - page 24

    24 DA T A SUBJECT T O CHANGE WITHOUT NOTICE 22-1650-13 PRODUCT D A T A TUD-9V OUTLINE DRA WING (ALL DIMENSIONS ARE IN INCHES) F rom Dwg. C341699 MODEL A B C D *UD2B060A9V3V** *UD2B080A9V3V** *UD2B100A9V3V** 17-1/2" 9-5/8" 16-1/4" 16" *UD2C080A9V4V** *UD2C100A9V5V** *UD2C080B9V4V** *UD2C100B9V5V** 21" 13-1/16" 19-3/4&qu ...

  • Trane TUD2D120B9V5VB - page 25

    22-1650-13 DA T A SUBJECT TO CHANGE WITHOUT NOTICE 25 ...

  • Trane TUD2D120B9V5VB - page 26

    Since the manufacturer has a policy of contin uous product and product data improvement, it reserves the right to change the design and specifications without notice. T echnical Literature - Pr inted in U .S .A. T rane 6200 T roup Highw ay T yler , TX 75707 PRODUCT D A T A ...

メーカー Trane カテゴリー Furnace

Trane TUD2D120B9V5VBのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- TUD2D120B9V5VBの取扱説明書
- Traneの製品カード
- パンフレット
- またはTrane TUD2D120B9V5VBの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Trane TUD2D120B9V5VBの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Trane TUD2D120B9V5VBの取り付け説明書、サービスマニュアル、簡易説明書、またはTrane TUD2D120B9V5VBのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Trane TUD2D120B9V5VBの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Trane TUD2D120B9V5VBデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがTrane TUD2D120B9V5VBを使用するのを助ける技術的文書のことです。説明書は通常、全てのTrane TUD2D120B9V5VBユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Traneの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Trane TUD2D120B9V5VBの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははTrane TUD2D120B9V5VBの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Trane TUD2D120B9V5VBに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Trane TUD2D120B9V5VBデバイスの基本機能を使うにあたってのヒント。 Trane TUD2D120B9V5VBのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Trane TUD2D120B9V5VBに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるTrane TUD2D120B9V5VBのメーカー/サービスへの連絡先に関する情報。

Trane TUD2D120B9V5VBについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもTrane TUD2D120B9V5VBの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがTrane TUD2D120B9V5VBで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)