    IE-iMcV-T1/E1/J1-LineTerm SFP and 1x9 Operation Manual Above illustration is representati ve; different m odels av ailable ...

  • IMC Networks IE-IMCV-T1 - page 2

    ii FCC Radio Frequency Inter ference Sta tement This equipment has been tested and found to comply wi th the limi ts fo r a Cla ss A c omput ing d evic e, pursu ant t o Pa rt 15 of the F CC Rules. These limits are designed to pr ovide reasonable protection against harmful interference when the equipment is o perated in a com mercial environment. Th ...

  • IMC Networks IE-IMCV-T1 - page 3

    iii Table of Cont ents FCC Radio Fre quency Interfe rence Stateme nt .................................................... ii Warranty ............ ................................................................. ............................... ii About the IE-iM cV-T1/E1/J1-LineTerm . ............................................................... ...

  • IMC Networks IE-IMCV-T1 - page 4

    1 Abou t the IE -iM cV-T1/E 1/J1 -Line Term, TP/ SFP IE-iMcV-T1/ E1/J1-Line Term, TP/S FP is an SNMP -Manageable m odule that c onverts standard TD M -based c opper transp orts ( T1, E1 , J1) to a single -mode or mul ti-mode fiber signal. It performs a standard “L ine Termination ” function as define d in GR - 820-CORE. This fun ction tran smit ...

  • IMC Networks IE-IMCV-T1 - page 5

    2 NOTE IE-iMcV- T1/E1/J1-L ineTer m, TP/SFP with SFP Module can be installed in an iMed iaChassis and MediaChas sis series. Installing an iMcV-Module iMcV-Modules install in IMC Ne tworks’ SNMP manageable iM ediaChassis series or in any MediaCha ssis/IE-Me diaChassis series. To install an iM cV-Module: 1. Remov e the blank b racket cov ering th e ...

  • IMC Networks IE-IMCV-T1 - page 6

    3 • Required CSU line Buildout (0db t o -22db) • Receiver BOOS T for T1 an d E1 applica tions • Fibe r tra nsceive rs mu st be fo r approp riate fiber r un, i .e. (SM or MM) • Management location must be at HOST unit Managed Modules The IE-iMcV-T1/E1/J1-LineTerm, TP/S FP modules are installed as a HOST-REMOTE pair and can be remotely man ag ...

  • IMC Networks IE-IMCV-T1 - page 7

    4 Conf igur ation Cont rol Some iMcV -Modules offer confi guration c ontrol; lab els on the fr ont faceplate a re identified as such. Configuration control has been implemented to assi st the end user by retaining the latest confi guration re gardle ss of ho w that con figurati on was implemented (via DIP S witch settings or S NMP). Historically, S ...

  • IMC Networks IE-IMCV-T1 - page 8

    5 NOTE If the end user has a mixture of standard iM cV-Modules as well as Configura tion Control iMcV-Modules, it is important to understand how SNMP and DIP Switches will impact the cards depending on their capa bility. Sta nda rd iMcV-Modul es cannot be upgrade d to Config ur atio n Co ntrol cap abilit y, s o it is str o ngly recomme nded to set ...

  • IMC Networks IE-IMCV-T1 - page 9

    6 DIP Switches The IE-iMcV-T1/E1/J1 -LineTerm, TP /SFP DI P Switches are locate d on S2 an d S3 on the PCB. T he loca tion of the S2 a nd S3 DIP Switches are displayed in the following diag ram : ...

  • IMC Networks IE-IMCV-T1 - page 10

    7 DIP Sw it ch S et ting s (S2 , S3) Switch Sett ings for Switch S2 T1/E1 Selec tion S2-1: OFF T1 Mode Selected default S2-1: O N E1 Mode Sele cted Receive Equaliz er Gain Limit (EGL) E1 iVIE W 2 S2-2: ON -12 dB (Short Haul) iVIE W 2 S2-2: OFF -43 dB (Long Haul) iVIE W 2 T1 iVIE W 2 S2-2: ON -36 dB (Long Haul) iVIE W 2 S2-2: OFF -30 dB (Limited Lon ...

  • IMC Networks IE-IMCV-T1 - page 11

    8 Switch Sett ings for Sw itch S3 Rese rve d S3-1: ON Reserved S3-1: OFF Reserved def ault Remo te Mana gemen t S3-2: ON Remote Management Enabled (only at the REMOTE end) S3-2: OF F Remote Ma nagement Disab led (onl y at th e LOCAL end) default Loopback Selection iVIEW 2 S3-3: ON S3-4: ON None iVIE W 2 default S3-3: OFF S3-4: ON Fiber Analog Loopb ...

  • IMC Networks IE-IMCV-T1 - page 12

    9 Featu re s The IE-iMcV-T1/E1/J1-LineTerm, TP/S FP module includes sever al feature s to facilitate maintenance and troubleshooting in an y T1/E1/J1 based TDM environment. SFP SFPs wit h Data and Diagn ostics Management Information (DD MI) can be in stalle d in the SFP port of the h ost and the remot e. Th is allows the end user to vie w the DDMI ...

  • IMC Networks IE-IMCV-T1 - page 13

    10 Loopback Modes This feature allows thre e distinct Loopba cks to be activated eit her through DIP Switches or iView 2 Management. Fiber Loopback An ana log Loopb ack at th e copper po rt back to t he fib er por t. It copies the received optical signal back to the optical line at t he copper port and c ontinu es to driv e the copper p ort, but ca ...

  • IMC Networks IE-IMCV-T1 - page 14

    11 Fault Loopback This switch enables or disables the Fault Loopback feature on the copper port. A normal copper line LOS fault will cause a Rem ote Alarm Indict or (RAI) to be sent on to the fiber line segment causing the n ormal AIS to be sent on the far en d copper port. The fau lt loop back fe ature provi des fo r a fault indica tion to be sent ...

  • IMC Networks IE-IMCV-T1 - page 15

    12 T1, E1 and J1 Selecti on This switch selects the data r ate to use on the copper line. The data rate selections available include the following: • T1/J1 (1.544 Mbps +/- 32 ppm) • E1 (2.04 8 Mbps +/- 32 ppm) By def ault this feature is set to T1. This feature can be selected onl y by setting the DIP S witches manually. Remote Management A DIP ...

  • IMC Networks IE-IMCV-T1 - page 16

    13 LED Operation The IE-iMcV-T1/E1/J1-LineTerm, TP/S FP module features seve ral diagnostic LEDs per port. The following L ED display function s are provid ed: Copper P ort LEDs ER Flashes yellow whe never a line code violation is received. LOS Glows red whe n the R J-48 is receiving n o signal and is in an LOS ALARM state. This condition will also ...

  • IMC Networks IE-IMCV-T1 - page 17

    14 Loopback Tes ting The IE-iMcV-T1 /E1/J1-LineTerm , TP/SFP incl udes three Loopback test m odes: Copper Loopback, Fibe r Loopback and I nternal Fiber Loopback. The follow ing illustrations show a typical prog ression of Loopback tests (i.e., starting by checking the copper segment at the l o cal side, then the fiber segment at the REMOTE side, et ...

  • IMC Networks IE-IMCV-T1 - page 18

    15 Pseud orandom Bit Sequence (PRB S) Testing To test usin g PRBS, con figure the IE-i McV- T1/ E1/J1 -LineTerm, TP/SFP m odules for No Loopback , and then confi gure th e Transmit Copper Dat a Source to P RBS. Config ure the lo cal device f or Loop back and st art the te st. Verif y the PRBS L ED is ON indicatin g no errors are being r eceive d. I ...

  • IMC Networks IE-IMCV-T1 - page 19

    16 Use the following LED in dications to identify the fa ult location: *DIP Switch S3-7 m ust be set t o ON for Fault Loopback to operate as illustrate d. The fo llowi ng table l ists the pi n configu ration for th e RJ-48 connecto r. Pin Signal 1 Receive Ring 2 Receive Tip 3 No Connection 4 Transmit R ing 5 Transmit Tip 6 No Connection 7 No Connec ...

  • IMC Networks IE-IMCV-T1 - page 20

    17 Spec if icat io ns Standard s Com pliance (T1, E1, J1): ANSI T1.102 -1993 ANSI T1.107.199 5 GR-820- CORE T1, E1, J1 Inter face: T1 (1.544 Mbps +/- 32 ppm) E1 (2.048 Mb ps +/- 32 ppm) J1 (1.544 Mbps +/- 32 ppm ) Power Consumption (Typical ): 0.550 Amps @ 5 V Operatin g Temp eratur e: -4°F to +158°F (-2 0°C to +70°C) Storage T empe rature : -4 ...

  • IMC Networks IE-IMCV-T1 - page 21

    18 Fiber Op tic Cleaning Guide lines Fiber Optic tran smitters an d receivers are e xtremely susce ptible to c ontamination by particles of d irt o r dust, which can obst ruct the optic p ath and cause performance degradation. Good system performan ce requires clean optics and c onnector ferrules. 1. Use fiber patch cord s (or connectors, if you te ...

  • IMC Networks IE-IMCV-T1 - page 22

    19 El ectro sta ti c Dis charg e Pre cau tions Electrostatic discharge (ESD) can cause dama ge to any product, add- in modules or stand alone units, containing ele ctronic componen ts. Always observe the following precauti ons when installing or han dling these kinds o f products 1. Do not remove unit from its protecti ve pa ckagin g until ready t ...

  • IMC Networks IE-IMCV-T1 - page 23

    20 Certi fic at ions CE: The products des cribed herein c o mply with the Counci l Directiv e on Electromagne tic Compatibili ty (2004/108/EC) European Directive 2002/96/EC (WEEE) requir es that any equipment that bears this symbol on product or pa ckaging m ust n ot be d ispose d of wit h unsorte d munic ipal waste. This symbol in dicates that the ...

  • IMC Networks IE-IMCV-T1 - page 24

    19772 Pauling • Foothill Ranc h, CA 92610-26 11 USA TEL: (94 9) 465 -3000 • FAX: (949 ) 465 -3020 www.imcnetworks.com © 2011 I MC Networks. A ll righ ts reserved . The info rmation in this doc ument is su bject to cha nge with o ut no tice . IM C N etwo rk s a ssum es no re spon sibi lity for an y errors th at may appear in this document. IE-i ...

メーカー IMC Networks カテゴリー Network Card

IMC Networks IE-IMCV-T1のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- IE-IMCV-T1の取扱説明書
- IMC Networksの製品カード
- パンフレット
- またはIMC Networks IE-IMCV-T1の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、IMC Networks IE-IMCV-T1の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、IMC Networks IE-IMCV-T1の取り付け説明書、サービスマニュアル、簡易説明書、またはIMC Networks IE-IMCV-T1のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、IMC Networks IE-IMCV-T1の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

IMC Networks IE-IMCV-T1デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがIMC Networks IE-IMCV-T1を使用するのを助ける技術的文書のことです。説明書は通常、全てのIMC Networks IE-IMCV-T1ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

IMC Networksの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. IMC Networks IE-IMCV-T1の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははIMC Networks IE-IMCV-T1の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。IMC Networks IE-IMCV-T1に関してこのドキュメントで見つけることができる全てのヒントの目次
3. IMC Networks IE-IMCV-T1デバイスの基本機能を使うにあたってのヒント。 IMC Networks IE-IMCV-T1のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。IMC Networks IE-IMCV-T1に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるIMC Networks IE-IMCV-T1のメーカー/サービスへの連絡先に関する情報。

IMC Networks IE-IMCV-T1についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもIMC Networks IE-IMCV-T1の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがIMC Networks IE-IMCV-T1で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)