    Operators Manual Installation, Operation & Service Floor Model Direct Steam Kettles MODELS : KDL, KDL-T , KDL-SH, KDL-TSH, KDP , KDP-T SE95007 Rev . 6 1333 East 179th St., Cle v eland, Ohio , U .S .A. 44110 Phone: (216) 481-4900 F ax: (216) 481-3782 Visit our web site at www .clev elandrange .com Clev elan d ™ Enodis ...

  • Cleveland Range KDP-T - page 2

    Shut off pow er at main fuse disconnect prior to ser vicing. Ensure kettle is at room temperature and pressure gauge is showing z ero or less prior to removing any fittings . Inspect unit daily f or proper operation. 0 Do not fill kettle abo v e recommended le v el marked on outside of k ettle. Surf aces ma y be e xtremely hot! Use protectiv e equi ...

  • Cleveland Range KDP-T - page 3

    GENERAL Installation of the unit must be accomplished by qualified installation personnel working to all applicable local and national codes. Improper installation of pr oduct could cause injury or damage. This unit is built to comply with applicable standards for manufacturers. Included among those appr oval agencies are: UL, NSF , ASME/Ntl.Bd., C ...

  • Cleveland Range KDP-T - page 4

    STEAM All steam plumbing to and from the kettle and steam boiler should be thoroughly cleaned and inspected for dirt and debris before final connection to the kettle are made. Check the rating plate for the maximum steam pressur e that your kettle is rated for . If the steam supply pressur e exceeds the rated pressur e, a pressur e reducing valve i ...

  • Cleveland Range KDP-T - page 5

    STEAM REQUIREMENTS FOR KETTLES Kettle Cap. Kettle 25 psi Steam 265°F 40 psi Steam 287°F 80 psi Steam 302°F U .S. Gal. Dia. Lbs./Hr . Hp./Hr . Lbs./Hr . Hp./Hr . Lbs./Hr . Hp./Hr . 40 26" 100 3 120 4 150 4.5 60 29.5" 150 4.5 190 5.5 230 7.0 80 33" 210 6.0 260 7.5 300 9.0 100 36" 260 7.5 320 9.5 390 11.0 125 40" 320 9.5 40 ...

  • Cleveland Range KDP-T - page 6

    OPERA TING INSTRUCTIONS CLEVELAND STEAM COOKING EQUIPMENT IS INTENDED FOR COMMERCIAL USE ONL Y BY PR OFESSIONALL Y TRAINED PERSONNEL. General Parts Drawing ITEM # DESCRIPTION 1. Steam Inlet V alve Opens and closes the steam supply to the kettle. 2. Hand Wheel Used for tilting the kettle up or down. Some units have an optional Power Tilt Control Swi ...

  • Cleveland Range KDP-T - page 7

    OPERA TION 1. Ensure that ther e is an adequate steam supply to the kettle. 2. For optimum perfor mance on free-standing floor model tilting kettles, open drain cock to drain condensate from the kettle’ s jacket, then close drain cock before applying steam to a cold kettle. 3. If the kettle is equipped with a tangent draw-off valve, ensure that i ...

  • Cleveland Range KDP-T - page 8

    CARE AND CLEANING Cooking equipment must be cleaned regularly to maintain its fast, efficient cooking performance and to ensure its continued safe, r eliable operation. The best time to clean is shortly after each use (allow unit to cool to a safe temperature). W ARNINGS ➩ Do not use detergents or cleansers that are chloride based or contain quat ...

  • Cleveland Range KDP-T - page 9

    ST AINLESS STEEL EQUIPMENT CARE AND CLEANING (Suppied courtesy of Nafem. For more information visit their web site at www .nafem.org) Contrary to popular belief, stainless steels ARE susceptible to rusting. Corrosion on metals is everywhere. It is r ecognized quickly on iron and steel as unsightly yellow/orange rust. Such metals are called “activ ...

  • Cleveland Range KDP-T - page 10

    F AUCET ASSEMBL Y ITEM P ART DESCRIPTION QTY . NO . NO . 3/4" Spouts 1. KE50825-2 KDL-60/80/100-T , KDP-60/80-T . . . . . . . . .1 KE50825-3 KDL-25/40-T , KDP-25/30/40-T . . . . . . . . . .1 KE50825-7 KDL-40/60/80-TSH, . . . . . . . . . . . . . . . . . .1 KE50825-5 ALL ST A TIONAR Y KETTLES . . . . . . . . . . .1 2. F A95022 Retaining Ring . . ...

  • Cleveland Range KDP-T - page 11

    STEAM CONTROL ASSEMBLIES ITEM NO . P ART NO . DESCRIPTION QTY . 1. KE51892 Retaining ring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2. KE51888 W asher . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 3. F A11501 V alve knob s ...

  • Cleveland Range KDP-T - page 12

    CONTROL CONSOLE COMPONENTS - HAND TIL T ITEM NO . P ART NO . DESCRIPTION QTY . 1. F A11134 Screw , #1-24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 2. F A11501 Screw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 3. SE ...

  • Cleveland Range KDP-T - page 13

    CONTROL CONSOLE COMPONENTS - HAND TIL T ...

  • Cleveland Range KDP-T - page 14

    ITEM NO . P ART NO . DESCRIPTION QTY . 1. KE55057-10 Gear Box Lid (25-60 gallon) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 KE55057-3 Gear Box Lid (80 gallon & up) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2. F A11134 Screw , 10-24 x 3/8" SS . . . . . . . . . . . . . ...

  • Cleveland Range KDP-T - page 15

    CONTROL CONSOLE COMPONENTS - POWER TIL T ITEM NO . P ART NO . DESCRIPTION QTY . 8. SE00028 Steam Inlet Knob Assembly (Item no. 7 included) . . . . . . . . . . . . . . . . . . . . . . .1 9. KE50441 Tilt Shaft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 10. F A95008 Locknut, 3/4-16 ...

  • Cleveland Range KDP-T - page 16

    HINGE ASSEMBL Y 1 5 3 2 13 12 6 4 7 11 8 10 9 9 ITEM NO . P ART NO . DESCRIPTION QTY . Hinge Assembly 1. - 11 KE50597-1 25 - 40 Gallon, 20 Gallon Full Jacketed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 KE50597-2 60 - 80 Gallon, 30 - 40 Gallon Full Jacketed . . . . . . . . . . . . . . . . . . . . . . . . . . .1 KE50597-3 100 - 1 ...

  • Cleveland Range KDP-T - page 17

    1 2 3 4 5 6 7 T ANGENT DRA W-OFF V AL VE ITEM NO. P ART NO. DESCRIPTION QTY . 1. - 7. KE50973 2” DRAW-OFF ASSEMBL Y . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 KE50972-B 3” DRA W-OFF ASSEMBL Y . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 1. F A95049 WING NUT , TD-2 . . ...

  • Cleveland Range KDP-T - page 18

    PRESSURE RELIEF V AL VE TESTING PROCEDURE The pressur e relief valve must be checked at least twice a year as part of the normal maintenance per formed. 1. With the kettle empty , fully open the steam valve and allow the kettle to preheat. 2. Stand to the side of the pressur e relief valve discharge tube and pull valve open for a maximum of one sec ...

  • Cleveland Range KDP-T - page 19

    TROUBLESHOOTING GUIDE This section contains information intended for use by Authorized Service Personnel only . PROBLEM A / Kettle heats too slowly or does not come to a boil. Probable Cause Remedy 1. Inadequate steam flow . Check for correct steam using chart below . If kettle is connected to a steamer and powered by a generator the units should b ...

メーカー Cleveland Range カテゴリー Hot Beverage Maker

Cleveland Range KDP-Tのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- KDP-Tの取扱説明書
- Cleveland Rangeの製品カード
- パンフレット
- またはCleveland Range KDP-Tの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Cleveland Range KDP-Tの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Cleveland Range KDP-Tの取り付け説明書、サービスマニュアル、簡易説明書、またはCleveland Range KDP-Tのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Cleveland Range KDP-Tの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Cleveland Range KDP-Tデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがCleveland Range KDP-Tを使用するのを助ける技術的文書のことです。説明書は通常、全てのCleveland Range KDP-Tユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Cleveland Rangeの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Cleveland Range KDP-Tの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははCleveland Range KDP-Tの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Cleveland Range KDP-Tに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Cleveland Range KDP-Tデバイスの基本機能を使うにあたってのヒント。 Cleveland Range KDP-Tのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Cleveland Range KDP-Tに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるCleveland Range KDP-Tのメーカー/サービスへの連絡先に関する情報。

Cleveland Range KDP-Tについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもCleveland Range KDP-Tの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがCleveland Range KDP-Tで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)