    W ALL MOUTED TYPE INDOOR UNITS AS072XHERA AS092XHERA AS122XHERA R410A MUL TI SPLIT SERIES ROOM AIR CONDITIONER OPERA TION & INST ALLA TION MANUAL No.0010577054 Please read this manual carefully before using this air conditioner . Please keep this manual safely for future use. ...

  • Haier AS092XHERA - page 2

    Contents Cautions ............................................................................................. Safety precautions............................................................................... Parts and Functions ........................................................................... Operation................................... ...

  • Haier AS092XHERA - page 3

    Cautions 1 Disposal of the old air conditioner Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment. It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The v ...

  • Haier AS092XHERA - page 4

    4. The wiring method should be in line with the local wiring standard. 5. The power cable and connecting cable are self-provided. The requirement of the connecting cable: All the cables shall have got the Local authentication certificate. 6. The breaker of the air conditioner should be all-pole switch; and the distance between its two contacts shou ...

  • Haier AS092XHERA - page 5

    3 W ARNING! Carefully r ead the following information in order to operate the air conditioner corr ectly . Below are listed three kinds of Safety Cautions and Suggestions. INSTRUCTIONS: These information can ensure the correct operation of the machine. Be sure to conform with the following important Safety Cautions. The Safety Cautions should be at ...

  • Haier AS092XHERA - page 6

    4 CAUTIONS! Conditioner should not be used for any other purpose other than air conditioning. Don't use air-conditioner for any other special purposes, e.g. the preservation and protection of food, animals, plants, pecision apparatus as well as work of art, otherwise the qualities of these stuffs may be damaged. Don't dismantle the outlet ...

  • Haier AS092XHERA - page 7

    5 CAUTION ! Please ask the dealer or specialist to install, never try by the users themselves. After the installation please be sure of the following conditions. Safety pr ecautions Incorrect installation may cause water leaking, shock and fire hazard. Please call dealer to install the air -conditioner . CAUTIONS ON INST ALLA TION Air -conditioner ...

  • Haier AS092XHERA - page 8

    Parts and Functions 6 Front panel Air inlet grille Louver LED board INDOOR UNIT FRONT VIEW INDOOR UNIT BACK VIEW Signal receiver Mounting plate Heat preservation pipe Connecting pipes Drainage pipes *HEAL TH LED DISPLA Y :PRESS HEAL TH/FRESH/STERILIZE BUTTON LED board OPERA TE COOL DR Y HEA T TIMER HEAL TH ...

  • Haier AS092XHERA - page 9

    7 Parts and Functions REMOTE CONTROLLER MODE CLOCK Used to set correct time. TIMER LIGHT Used to set temp.,temp. range:16 C~30 C SLEEP Used to select sleep mode HOUR Used to set clock and timer setting. RESET Used to reset the controller back to normal condition. LOCK Used to select TIMER ON, TIMER OFF , TIMER ON/OFF . Used to lock buttons and LCD ...

  • Haier AS092XHERA - page 10

    8 MODE SLEEP SWING CLOCK TIMER SET LOCK LIGHT RESET STERILIZE 1 2 3 HEALTH AIRFLOW FRESH CODE Operation Clock set When unit is started for the first time and after replacing batteries in remote controller , clock should be adjusted as follows: Press CLOCK button, "AM"or "PM" flashes. Press or to set correct time. Each press will ...

  • Haier AS092XHERA - page 11

    Operation Auto 2 1 Press ON/OFF button Unit starts running. The previous status appears on the display (except. TIMER, SLEEP mode) Press MODE button. For each press, operation mode changes as follows: 4 Remote controller Press ON/OFF button Unit stops running. Press FAN,For each press, operation mode changes as follows: Remote controller ON OFF TEM ...

  • Haier AS092XHERA - page 12

    10 A Operation Cooling Press ON/OFF button Unit starts running. The previous status appears on the display (except. TIMER, SLEEP mode) Press MODE button. For each press, operation mode changes as follows: Select temp. button Press TEMP button Every time the button is pressed, temp. setting increases 1 C Every time the button is pressed, temp. setti ...

  • Haier AS092XHERA - page 13

    1 1 A Operation Dry Press ON/OFF button Unit starts running. The previous status appears on the display (except. TIMER, SLEEP mode) Press MODE button. For each press, operation mode changes as follows: Select Drying operation shows" " Dry operation starts Select temp. button Press TEMP button Every time the button is pressed, temp. settin ...

  • Haier AS092XHERA - page 14

    12 A Operation Fan Press ON/OFF button Unit starts running. The previous status appears on the display (except. TIMER, SLEEP mode) Press MODE button. For each press,operation mode changes as follows: Select Fan operation shows " ", Fan operation starts. Press ON/OFF button Unit stops running, and when entering this mode for the next time, ...

  • Haier AS092XHERA - page 15

    13 A Operation Heating Press ON/OFF button Unit starts running. The previous status appears on the display (except. TIMER, SLEEP mode) Press MODE button. For each press,operation mode changes as follows: Select Heating operation " " appears and Heating operation starts. Press F AN button. For each press, fan speed changes as follows: 4 1 ...

  • Haier AS092XHERA - page 16

    14 A Operation Air flow adjustment Swing louvers (V ertical louvers) Up and down Put louvers at up position in cooling and down position in heating mode. This will be helpful to keep an even room temp. Note: In cooling or dry operation, don't put horizontal louvers at downward position for a long time, or outlet grill might get frosted. Don&ap ...

  • Haier AS092XHERA - page 17

    15 A Operation Sleep Remote control unit Usage of the Sleep function After starting, set the Run mode and press the Sleep button. Run mode 1. In cooling and dry After starting of the Sleep operation, the temperature will be raised for 1 C higher than the set temperature 1 hour later ,and be raised for 1 C after another hour . It continues under tha ...

  • Haier AS092XHERA - page 18

    16 A Operation T imer on/off operation Remote control unit TIMER operation Set Clock correctly before starting T imer operation (refer to page 2) Y ou can let unit start or stop automatically at following times: Before you wake up in the morning, or get back from outside or after you fall asleep at night. TIMER ON/OFF (1) After unit start, select y ...

  • Haier AS092XHERA - page 19

    17 A Operation T imer on-off function Remote controller operation TIMER ON-OFF (1) After unit start, select your desired operation mode. Operation mode will be displayed on LCD. (2) TIMER mode selection Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: (3) Timer setting for TIMER ON Press HOUR bu ...

  • Haier AS092XHERA - page 20

    18 A Operation After turning on the unit and set the desired working mode. Press the Health button, the LCD will display " ", the unit begins health operation (start the negative ion generation device). Press the Health button again, the " " displayed on the LCD disappears, health operation is cancelled (turn off the negative io ...

  • Haier AS092XHERA - page 21

    Notes for safety Clean the dust filter periodically: Blockage of the dust filter would reduce the cooling and heating effect, consume more power , water would be leaked during cooling, and other failures would also occur . 19 ! ! Use the fuse of required capacity: Never use steel wire or copper wire to take place of the fuse. Never connect the eart ...

  • Haier AS092XHERA - page 22

    Operation and Maintenance 20 Emergency and T est Operation Use this operation only when the remote controller is defective or lost. When the emergency operation switch is pressed "Pi" sound is heard once, which means the start of this operation. In this operation,the system automatically selects the operation modes, cooling or heating, ac ...

  • Haier AS092XHERA - page 23

    21 The followings are not malfuncition Hua Hua T r ouble shooting W ater flowing sound is heard When the air conditoner is started, when the compressor starts or stops during operation or when the air conditioner is stopped,it som- etimes sounds “ Bi- Bi-” or “Godo-Godo”. It is the flowing sound of the refrigerant , not a malfunction. Crack ...

  • Haier AS092XHERA - page 24

    22 **? ON OFF Air does not blow or the fan speed cannot be changed during drying. In DR Y mode, when room temperature becomes 2 C higher than temperature setting, unit rill run intermittently at LO speed regardless of F AN setting During heating,indoor fan is still running even unit is stopped. T o get ride of the excess heat, indoor fan will conti ...

  • Haier AS092XHERA - page 25

    23 Customer Need-to-know Customer Need-to-know Please install the air conditioner according to the requirements specified in this manual to ensure the air conditioner work well. Be careful not to scratch the surface of the case during moving the air conditioner . Please keep the installation manual for future reference when maintenance and changing ...

  • Haier AS092XHERA - page 26

    24 W ARNING This system should be applied to places as office, restaurant, residence and the like. Application to inferior environment such as engineering shop could cause equipment malfunction. Please entrust installation to either the company which sold you the equipment or to a professional contractor . Defects from improper installations can be ...

  • Haier AS092XHERA - page 27

    25 PRECAUTION Self-contained accessories 3. Accessories for installation Name of Parts No. A B C D E F Non-adhesive T ape Adhesive tape Connecting Hose Gypsum powder Drain hose Heat insulation material 2. Preparation for installation Installation tools 7 Pipe Cutter 14 Refrigeration Oil 6 Spanner 13 Scraper or File 5 Shifting Spanner 12 Measuring T ...

  • Haier AS092XHERA - page 28

    5. Method for Cutting and Expanding Pipes. 26 Make a hole of 60mm in diameter , slightly descending to outside the wall. Install piping hole cover and seal it off with putty after installation. 4. Drawing of pipe Rear piping Draw pipes and the drain hose, then fasten them with the adhesive tape. Left Left-rear , piping. In case of left side piping, ...

  • Haier AS092XHERA - page 29

    27 Heat insulation material Drain hose Piping Indoor/outdoor electric cable signal wire Change-f or -fresh-air tube Indoor/outdoor electric cord and drain hose must be bound with refrigerant piping by protecting tape 8. Indoor unit communication addr esses setting 1.There are two methods to set the communication address A. Use the remote controller ...

  • Haier AS092XHERA - page 30

    28 I. If you want to change the address, please repeat the above steps from E to G. J. After setting all the addresses, please power off the system and then power on again. Otherwise the system will not start to work. K. Once the addresses are successfully set, please do not change it any more to avoid confusion. 3. Address setting procedure when u ...

  • Haier AS092XHERA - page 31

    29 When tr ouble happens Insufficient cooling or heating The operation controller adjusted as required Air filter too dirty ? Horizontal swing louver upward ? (in HEA T mode) Any obstacle exists at the air inlet or outlet? Door or window left opened ? Insufficient cooling Any other heat sources in the room? Sunlight direct into the room ? T oo crow ...

  • Haier AS092XHERA - page 32

    30 Failur e code Note: 1. Please contact the installers or distributors when trouble happens to repair it. 2. T urn the power off and power on again, if the failure code recurs, please change the indoor unit PCB. 3. Failrue codes maked with are resumable. TROUBLE SHOOTING F AILURE CODE (TIMER LED OF INDOOR RECEIVER BOARD FLASHES TIMES) POSSIBLE REA ...

  • Haier AS092XHERA - page 33

    HAIER GROUP Qingdao Haier Air Conditioner Electric Co., Ltd. Address: Haier Garden, Qianwangang Road, Economic Development Zone, Qingdao, Shandong 266500, P .R.China W eb Site: http://www .haier .com ...

メーカー Haier カテゴリー Air Conditioner

Haier AS092XHERAのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- AS092XHERAの取扱説明書
- Haierの製品カード
- パンフレット
- またはHaier AS092XHERAの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Haier AS092XHERAの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Haier AS092XHERAの取り付け説明書、サービスマニュアル、簡易説明書、またはHaier AS092XHERAのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Haier AS092XHERAの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Haier AS092XHERAデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがHaier AS092XHERAを使用するのを助ける技術的文書のことです。説明書は通常、全てのHaier AS092XHERAユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Haierの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Haier AS092XHERAの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははHaier AS092XHERAの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Haier AS092XHERAに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Haier AS092XHERAデバイスの基本機能を使うにあたってのヒント。 Haier AS092XHERAのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Haier AS092XHERAに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるHaier AS092XHERAのメーカー/サービスへの連絡先に関する情報。

Haier AS092XHERAについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもHaier AS092XHERAの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがHaier AS092XHERAで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)