  • American Dryer Corp. ML-130 III - page 1

    ML-130 III / ML-130DR Inst allation Manual Phase 7 / HSI and DSI / Dual T imer / F .S.S. W ARNING: For your safety the information in this manual must be followed to minimize the risk of fire or explosion and to prevent property damage, personal injury or death. — Do not store or use gasoline or other flammable vapors and liquids in the vicinity ...

  • American Dryer Corp. ML-130 III - page 2

    2 American Dryer Corp. 1 1333 5 - 12 “IMPORT ANT NOTE T O PURCHASER” Information must be obtained from your local gas supplier on the instructions to be followed if the user smells gas. These instructions must be posted in a prominent location near the dryer . FOR Y OUR SAFETY Do not store or use gasoline or other flammable vapors and liquids i ...

  • American Dryer Corp. ML-130 III - page 3

    1 13335 - 12 www .amdry .com 3 IMPORT ANT Y ou must disconnect and lockout the electric supply and the gas supply or the steam supply before any covers or guards are removed from the machine to allow access for cleaning, adjusting, installation, or testing of any equipment per OSHA standards. Please observe all safety precautions displayed on the e ...

  • American Dryer Corp. ML-130 III - page 4

    4 American Dryer Corp. 1 1333 5 - 12 Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Purchaser/user should consult the local gas supplier for proper instructions to be followed in the event the user smells gas. The instructions should be posted in a prominent location. W ha t T o Do ...

  • American Dryer Corp. ML-130 III - page 5

    1 13335 - 12 www .amdry .com 5 Articles lef t in the dryer after the drying and cooling cycles have been completed can create a fire hazard. ▲ WARNING ! Do not operate steam dryers with more than 125 psi (8.61 bar) steam pressure. Excessive steam pressure can damage steam coil and/or harm personnel. Replace leaking flexible hoses or other steam f ...

  • American Dryer Corp. ML-130 III - page 6

    6 American Dryer Corp. 1 1333 5 - 12 ML-130 Specifications _____________________________________________________________ MA X I MUM CA PA C I TY (D RY W E I GHT ) 1 2 0 l b 54.43 kg T U M BLER DI AM ET ER 4 4 .6 3 ” 1 1 3. 35 cm T U M B L E R D E P T H 42- 1/8” 107 cm T UMB LE R V OLUME 3 8 . 1 0 c u f t 1078.872 L TUM B L E R / D R IV E M O TO ...

  • American Dryer Corp. ML-130 III - page 7

    1 13335 - 12 www .amdry .com 7 ML-130 Specifications _____________________________________________________________ ...

  • American Dryer Corp. ML-130 III - page 8

    8 American Dryer Corp. 1 1333 5 - 12 ML-130DR Specifications __________________________________________________________ MA X I MUM C A PA C I TY (D RY W E I GHT ) 1 2 0 l b 54.43 kg T U M BLER DI AM ET ER 4 4 -1 /2 ” 1 1 3. 03 cm T U M B L E R D E P T H 42- 1/2” 107.95 cm T U M B L E R V O L U M E 38. 20 cu ft 1081. 704 L T UMB LE R/D RI V E MO ...

  • American Dryer Corp. ML-130 III - page 9

    1 13335 - 12 www .amdry .com 9 ML-130DR Specifications __________________________________________________________ ...

  • American Dryer Corp. ML-130 III - page 10

    10 American Dryer Corp. 1 1333 5 - 12 Installation Procedures ______________ Installation should be performed by competent technicians in accordance with local and state codes. In the absence of these codes, the installation must conform to applicable American National S tandards: ANSI Z223.1-LA TEST EDITION (National Fuel Gas Code) or ANSI/NFP A N ...

  • American Dryer Corp. ML-130 III - page 11

    1 13335 - 12 www .amdry .com 11 Exhaust T ransition Piece (Gas and Electric Only!) Inside the tumbler of this dryer is an exhaust transition piece that must be installed on the outlet of the exhaust before any further venting is connected: Remove the exhaust transition piece from the tumbler and place it on the exhaust outlet. Using the screws prov ...

  • American Dryer Corp. ML-130 III - page 12

    12 American Dryer Corp. 1 1333 5 - 12 EXAMPLE: For a bank of 6 gas dryers, 2 openings measuring 3 feet by 3 feet (0.91 meters by 0.91 meters) are acceptable. Allowances must be made for remote or constricting passageways or where dryers are located at excessive altitudes or predominantly low pressure areas. IMPORT ANT : Make-up air must be provided ...

  • American Dryer Corp. ML-130 III - page 13

    1 13335 - 12 www .amdry .com 13 NOTE: When the exhaust ductwork passes through a wall, ceiling, or roof made of combustible materials, the opening must be 2-inches (5.08 cm) larger than the duct (all the way around). The duct must be centered within this opening. Outside Ductwork Pr otection T o protect the outside end of the horizont al ductwork f ...

  • American Dryer Corp. ML-130 III - page 14

    14 American Dryer Corp. 1 1333 5 - 12 * 3-Wire is available. 7/31/08 IMPORT ANT : The dryer must be connected to the electric supply shown on the data label. In the case of 208 V AC or 230/240 V AC, the supply voltage must match the electric service specifications of the data label exactly . 208 V AC and 230/240 V AC are not the same. Any damage do ...

  • American Dryer Corp. ML-130 III - page 15

    1 13335 - 12 www .amdry .com 15 * 3-Wire is available. 7/31/08 IMPORT ANT : The dryer must be connected to the electric supply shown on the data label. In the case of 208 V AC or 230/240 V AC, the supply voltage must match the electric service specifications of the data label exactly . NOTE: ADC reserves the right to make changes in specifications ...

  • American Dryer Corp. ML-130 III - page 16

    16 American Dryer Corp. 1 1333 5 - 12 Gas Supply The gas dryer installation must meet the American National S tandard...National Fuel Gas Code ANSI Z223.1-LA TEST EDITION, or in Canada, the Canadian Installation Codes CAN/CGA-B149.1 M91 (Natural Gas) or CAN/CGA-B149.2- M91 (L.P . Gas) or LA TEST EDITION, as well as local codes and ordinances and mu ...

  • American Dryer Corp. ML-130 III - page 17

    1 13335 - 12 www .amdry .com 17 Type of G as Mani fol d Pressure * I n-Li ne Pressure Na tu ra l 3.5 in wc 6. 0 - 12. 0 in wc 8.7 mb 14. 92 - 29. 9 mb Li qu i d Propane 10. 5 in wc 1 1.0 in wc 26. 1 mb 27.4 mb T echnical Gas Da ta Gas Specifications Shaded areas are stated in metric equivalent s * Measured at outlet side of gas valve pressure tap w ...

  • American Dryer Corp. ML-130 III - page 18

    18 American Dryer Corp. 1 1333 5 - 12 NOTE: The dryer must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa). Steam Inf or mation ____________________ It is your responsibility to have all ...

  • American Dryer Corp. ML-130 III - page 19

    1 13335 - 12 www .amdry .com 19 Steam Damper Air System Connections The steam dryer is manufactured with a pneumatic (piston) damper system, which requires an external supply of compressed air 0.75 cfh (0.02 cmh). The air connection is made to the steam damper solenoid valve, which is located at the rear inner top area of the dryer just above the e ...

  • American Dryer Corp. ML-130 III - page 20

    20 American Dryer Corp. 1 1333 5 - 12 Steam Damper Air Piston (Flow Control) Operation Adjustment System Although the damper operation was tested and adjusted prior to shipping at 80 psi (5.51 bar), steam damper operation must be checked before the dryer is put into operation. Refer to the previous page for instructions to check steam damper system ...

  • American Dryer Corp. ML-130 III - page 21

    1 13335 - 12 www .amdry .com 21 Shutdown Instructions _______________ If the dryer is to be shutdown (t aken out of service) for a period of time, the following must be performed: Discontinue power to the dryer either at the external disconnect switch or the circuit breaker . Discontinue the gas or steam supply: GAS MODELS – discontinue the gas s ...

  • American Dryer Corp. ML-130 III - page 22

    22 American Dryer Corp. 1 1333 5 - 12 Dual Timer Dr y er Models Select drying time and cool down time desired. T urn heat timer clockwise to desired time (i.e., 1 minute to 60 minutes). T urn cool down timer clockwise to desired time (i.e., 0 minutes to 15 minutes). Select drying temperature. Push “S tart” button and the dryer will now start. T ...

  • American Dryer Corp. ML-130 III - page 23

    1 13335 - 12 www .amdry .com 23 Shipping charges are not the responsibility of ADC. All returns should be “prepaid” to the factory . Any “C.O.D.” or “COLLECT” returns will not be accepted. IMPORT ANT : No replacements, credit s, or refunds will be issued if the claim cannot be processed due to insufficient information. The party filing ...

  • American Dryer Corp. ML-130 III - page 24

    24 American Dryer Corp. 1 1333 5 - 12 NOTE: A back draft damper that is sticking p artially closed can result in slow drying and shutdown of the heat circuit safety switches or thermostat s. When cleaning dryer cabinet(s), avoid using harsh abrasives. A product intended for the cleaning of appliances is recommended. Adjustments 7 Days After Install ...

  • American Dryer Corp. ML-130 III - page 25

    1 13335 - 12 www .amdry .com 25 Procedur e f or Functional Check of Replacement Components ________ Micropr ocessor Controller (Computer) Board Upon completing installation of the replacement microprocessor controller (computer) board, reestablish power to the dryer . S tart the drying cycle by pressing any of the preset cycles in letters A-F . V e ...

  • American Dryer Corp. ML-130 III - page 26

    26 American Dryer Corp. 1 1333 5 - 12 Manual Reset Bur ner Hi-Limit Instr uctions _________ Phase 7 This dryer was manufactured with a manual reset burner hi-limit thermostat, which is monitored by the Phase 7 computer . If the burner hi-limit is open prior to the start of the drying cycle, the dryer will start moment arily and then shut down, the ...

  • American Dryer Corp. ML-130 III - page 27

    1 13335 - 12 www .amdry .com 27 Electrical power must be provided to the dryer at all times. If the main electrical power supply to the dryer is disconnected, the F .S.S. is inoperative!! ▲ WARNING ! Typical wa ter supply ... Optional Manual Bypass Provisions are made in the dryer F .S.S. for the installation of an optional manual bypass. Dependi ...

  • American Dryer Corp. ML-130 III - page 28

    ADC Part No. 1 13335 12 - 07/31/08 - 5 ...

メーカー American Dryer Corp. カテゴリー Clothes Dryer

American Dryer Corp. ML-130 IIIのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- ML-130 IIIの取扱説明書
- American Dryer Corp.の製品カード
- パンフレット
- またはAmerican Dryer Corp. ML-130 IIIの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、American Dryer Corp. ML-130 IIIの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、American Dryer Corp. ML-130 IIIの取り付け説明書、サービスマニュアル、簡易説明書、またはAmerican Dryer Corp. ML-130 IIIのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、American Dryer Corp. ML-130 IIIの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

American Dryer Corp. ML-130 IIIデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAmerican Dryer Corp. ML-130 IIIを使用するのを助ける技術的文書のことです。説明書は通常、全てのAmerican Dryer Corp. ML-130 IIIユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

American Dryer Corp.の取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. American Dryer Corp. ML-130 IIIの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAmerican Dryer Corp. ML-130 IIIの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。American Dryer Corp. ML-130 IIIに関してこのドキュメントで見つけることができる全てのヒントの目次
3. American Dryer Corp. ML-130 IIIデバイスの基本機能を使うにあたってのヒント。 American Dryer Corp. ML-130 IIIのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。American Dryer Corp. ML-130 IIIに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAmerican Dryer Corp. ML-130 IIIのメーカー/サービスへの連絡先に関する情報。

American Dryer Corp. ML-130 IIIについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAmerican Dryer Corp. ML-130 IIIの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAmerican Dryer Corp. ML-130 IIIで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)