    -- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. -- WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a near by phone. Follow the gas supplie ...

  • Lochinvar 1.5 - page 2

    2 Hazard definitions The following defined terms are used throughout this manual to bring attention to the presence of hazards of various risk level s or to important information concerning the life of the product.  DANGER  WARNING  CAUTION CAUTION NOTICE DANGER indicates an imminently hazardous situation which, if not avoided, will result ...

  • Lochinvar 1.5 - page 3

    User’s Information Manual Please read before proceeding The Crest Installation and Operation Manual along with the Crest Service Manual are for use only by a qualified heating installer/service technician. Refer only to this User’s Information Manual for your reference. Improper installation, adjustment, alteration, service or maintenance can c ...

  • Lochinvar 1.5 - page 4

    1 Prevent combustion air contamination 4 If the boiler combustion air inlet is located in a laundry room or pool facility, for example, these areas will always contain hazardous contaminants. To prevent the potential of severe personal injury or death, check for areas and products listed in Table 1A before installing the boiler or air inlet piping. ...

  • Lochinvar 1.5 - page 5

    2 Maintenance schedule 5  WARNING Follow the maintenance procedures given throughout this manual. Failure to perform the service and maintenance or follow the directions in this manual could result in damage to the boiler or system, resulting in severe personal injury, death, or substantial property damage. Service technician (see the Crest Serv ...

  • Lochinvar 1.5 - page 6

    6 2 Maintenance schedule Maintenance procedures Boiler must be serviced and maintained  WARNING The boiler must be inspected and started annually at the beginning of the heating season by a qualified service technician. In addition, the maintenance and care of the boiler designated on page 5 of this manual and explained on pages 6 through 8 must ...

  • Lochinvar 1.5 - page 7

    2 Maintenance schedule (continued) 7  WARNING The condensate trap (FIG. 2-1) must be filled with water during all times of boiler operation to avoid flue gas emission from the condensate drain line. Failure to fill the trap could result in severe personal injury or death. FROM CONDENSAT E VENT ON BOILER FROM CON DENSATE DRAIN ON BOILER TO FLOOR ...

  • Lochinvar 1.5 - page 8

    2 Maintenance schedule 8  WARNING Have leaks fixed at once by a qualified service technician. Failure to comply could result in severe personal injury, death, or substantial property damage. Operate relief valve 1. Before proceeding, verify that the relief valve outlet has been piped to a safe place of discharge, avoiding any possibility of scal ...

  • Lochinvar 1.5 - page 9

    9 3 Operating instructions F OR YO UR S AF ET Y RE AD BEF O RE OP ERAT ING W A RNI NG : I f y ou do no t f oll ow t hes e i nstr uct ions ex a c tl y , a f ir e or ex plosi on m ay r es ult caus i n g pr o per t y dam a ge, per so nal i njury , or los s of lif e. A. T h i s ap p l i an ce d o e s no t h a ve a p i l o t. It i s eq ui pp ed w i t h ...

  • Lochinvar 1.5 - page 10

    10 4 SMART TOUCH control module Outlet Water Temperature - This is the boiler outlet temperature. Inlet Water Temperature - This is the boiler inlet temperature. System Supply Temperature - This is the water temperature as measured by the system supply sensor located in the downstream piping (if connected). System Return Temperature - This is the w ...

  • Lochinvar 1.5 - page 11

    11 4 SMART TOUCH control module (continued) Figure 4-2 Main Menu Screen Use the Main Menu Screen (FIG. 4-2) to access the screens necessary to set temperatures, operating conditions, and monitor boiler operation. The Crest is equipped with a SMART TOUCH control system. All menu options are accessed by touching the screen with your finger or a stylu ...

  • Lochinvar 1.5 - page 12

    Revision Notes: Revision A (ECO #C07970) initial release. Revision B (ECO C11613) reflects the addition of models 4.0 and 5.0. FB-USER Rev B 11/12 ...

メーカー Lochinvar カテゴリー Boiler

Lochinvar 1.5のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 1.5の取扱説明書
- Lochinvarの製品カード
- パンフレット
- またはLochinvar 1.5の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Lochinvar 1.5の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Lochinvar 1.5の取り付け説明書、サービスマニュアル、簡易説明書、またはLochinvar 1.5のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Lochinvar 1.5の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Lochinvar 1.5デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがLochinvar 1.5を使用するのを助ける技術的文書のことです。説明書は通常、全てのLochinvar 1.5ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Lochinvarの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Lochinvar 1.5の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははLochinvar 1.5の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Lochinvar 1.5に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Lochinvar 1.5デバイスの基本機能を使うにあたってのヒント。 Lochinvar 1.5のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Lochinvar 1.5に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるLochinvar 1.5のメーカー/サービスへの連絡先に関する情報。

Lochinvar 1.5についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもLochinvar 1.5の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがLochinvar 1.5で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)