    1 PLACE THESE INSTRUCTIONS ADJACENT TO HEA TER AND NOTIFY OWNER T O KEEP FOR FUTURE REFERENCE. PRINTED 0307 197373-003 CYCLONE Xi ® Model BTH 300A, 400A, 500A COMME R CIA L GAS W A TER HEA TER GAS-FIRED POWER BURNER FOR DOMESTIC HOT W A TER Thank you for buying t his energy e fcient wa ter heater from A.O. Smith W ater Products Company . We app ...

  • A.O. Smith 500A - page 2

    2 These designs comply with the current edition of the American National Standard for Gas Water Heaters, V olume III, ANSI Z21.10.3 / CSA 4.3 as an automatic circulating tank water heater , and automatic storage water heaters. Detailed installation diagrams are found in this manual. These diagrams will serve to provide the installer with a referenc ...

  • A.O. Smith 500A - page 3

    3 DANGER THIS WATER HEATER IS EQUIPPED WITH AN ADJUSTABLE THERMOSTAT TO CONTROL WATER TEMPERATURE. HOT WATER TEMPERATURES REQUIRED FOR AUTOMATIC DISHWASHER AND LAUNDRY USE CAN CAUSE SCALD BURN S RE SULTIN G IN SER IOUS PERSO NAL INJURY AND /OR DEATH. THE TEMPERATURE AT WHICH INJURY OCCURS VARIES WITH THE PERSON’S AGE AND TIME OF EXPOSURE. THE SLO ...

  • A.O. Smith 500A - page 4

    4 “A T A GLANCE ” BTH 300/400/500 QUICK INST ALLA TION TIPS Horizontal Sidewall V enting V er tical Roof top Venting ...

  • A.O. Smith 500A - page 5

    5 The temperature may be adjusted from 80°F/27°C to 180°F/82°C. The temperature was adjusted to 120°F/49°C before the heater was shipped from the factory . It is recommended that lower water temperatures be used to avoid the risk of scalding. It is further recommende d, in all cases, that the water temperature be set for the lowest temperatur ...

  • A.O. Smith 500A - page 6

    6 TH E HEA TE R SHA LL BE LOCA TE D OR PR OT ECT ED SO IT IS NO T SUBJECT TO PHYSICAL DAMAGE BY A MOVING VEHICLE. DO NOT LOCA TE THE HEA TER WHERE NOISE FROM THE EXHAUST OR INT AKE WILL BE OBJECTIONABLE. THIS INCLUDES LOCA TIONS CLOSE TO OR ACROSS FROM WINDOWS AND DOORS. A VOID ANCHORING THE VENT AND INT AKE PIPES DIRECTL Y TO FRAMED WALLS, FLOORS ...

  • A.O. Smith 500A - page 7

    7 CLEARANCES These heaters are approved for installation on combustible ooring in an alcove when the minimum clearances from any combustion construction are followed as indicated in Figure 4. In all installations the minimum combustible clearances from any vent piping shall be 0". V ent piping passing through a combustible wall or ceiling m ...

  • A.O. Smith 500A - page 8

    8 INST ALLA TION REQUIREMENTS FOR THE COMMONWEAL TH OF MASSACHUSETTS For all side wall terminated, horizontally vented power vent, direct ven t, and pow er dir ect ven t gas fue led wat er hea ter s inst all ed in ever y dwelling, building or structure used in whole or in part for residential purpos es, including those owned or operated by the Comm ...

  • A.O. Smith 500A - page 9

    9 US DIRECT VENT CANADIAN DIRECT VENT FIGURE 5. CAUTION TO PREVENT EXHAUSTING PRODUCTS FROM CIRCULA TING TO THE AI R I NT AKE IN WI NDY /C OLD AR EAS , T HE MAX IM UM PRA CT ICA L DIST ANCE BETWEEN THESE TWO TERMINALS IS RECOMMENDED. ...

  • A.O. Smith 500A - page 10

    10 US HORIZONT A L VENT CANADIAN HORIZONT AL VENT FIGURE 6. CAUTION TO PREVENT EXHAUSTING PRODUCTS FROM CIRCULA TING TO THE AI R I NT AKE IN WI NDY /C OLD AR EAS , T HE MAX IM UM PRA CT ICA L DIST ANCE BETWEEN THESE TWO TERMINALS IS RECOMMENDED. ...

  • A.O. Smith 500A - page 11

    1 1 W ARNING N EV ER OP E R A T E TH E HE AT E R U N L E S S IT I S VE N T E D T O T H E O U TD O O R S AN D H AS A D EQ U A T E A I R SU P P L Y T O A V O I D RI S K S O F I MP RO P ER O P ER AT I O N, F I RE , E XP LO S IO N O R AS P H YX IA T IO N. VENT PIPE TERMINA TION NOTE: Before installing venting, determine place of vent pipe termination. ...

  • A.O. Smith 500A - page 12

    12 2. The horizontal centerline of the intake vent terminal may not be located lower than the horizontal centerline of the exhaust vent terminal (see Figure 9). FIGURE 9. INST ALLA TION SEQUENCE For installations in the City of Los Angeles, California Category IV PVC Pipe such as that manufactured by Brownline Pipe Company , must be used as vent pi ...

  • A.O. Smith 500A - page 13

    13 2. Drill a pilot hole approximately 1/4" (6 mm) outside of the marked circle. This pilot hole is used as a starting point for a saws- all or sabre saw blade. Cut around the marked circle staying approximately one quarter inch outside the line. (This will allow the vent pipe to easily slide through the opening). The resulting gap will be cov ...

  • A.O. Smith 500A - page 14

    14 VENT PIPE PREP ARA TION 1. INITIAL PREP ARA TION A. Make sure the solvent cement you are planning to use is designed for the specic application you are attempting. B. Kn ow the phys ic al and ch em ic al char ac te ri st ics and limi ta ti on s of the PVC, PVC cellula r core, ABS or CPVC pipin g materi als that you are about to use. C. Know t ...

  • A.O. Smith 500A - page 15

    15 CAUTION THE W A TER HEA TER IS POLARITY SENSITIVE. BEFORE APPL YING ELECTRICITY TO THIS HEA TER BE CERT AIN THA T SUP PL Y NEUT RAL WIRE TO GRO UND CHEC K INDI CA TES ZERO VOL T AGE. HOT SURF ACE IGNITER The Hot Surface Igniter is a device that ignites the main burner by high temperature (>1800°F or >982°C). When 120V AC is applied to th ...

  • A.O. Smith 500A - page 16

    16 T o prevent damage, care must be taken not to apply too much torque when attaching gas supply pipe to gas valve inlet. Apply joint compounds (pipe dope) sparingly and only to the male threads of pipe joints. Do not apply compound to the rst two threads. Use compounds resistant to the action of liqueed petroleum gases. DISCONNECT THE APPLIA ...

  • A.O. Smith 500A - page 17

    17 codes or contact the water supplier or local plumbing inspector on how to control this situation. W A T E R ( PO T A B LE ) H EA T I N G A N D S P A C E H E A TI N G 1. All piping components connected to this unit for space heating applications shall be suitable for use with potable water . 2. T oxic chemicals, such as those used for boiler trea ...

  • A.O. Smith 500A - page 18

    18 FIGURE 15. BTH 300 WIRING DIAGRAM ...

  • A.O. Smith 500A - page 19

    19 FIGURE 16. BTH 400 AND 500 WIRING DIAGRAM ...

  • A.O. Smith 500A - page 20

    20 OPERA TION SEQUENCE OF OPERA TION T ypical Control/Appliance Operating Sequence 1. When the control is powered, it should display the unit model, water temperature, setting temperature and heater status. 2. If the contro l determ ine s tha t the actu al water temp era ture insi de the tank is below the programme d tempera ture setpoint less the ...

  • A.O. Smith 500A - page 21

    21 3. Adjusting the Operating Set Point The Operating Set Point of this water heater determines the regulated temperature for the water in the tank. This parameter is adjusted in the T emperature menu. Items in this menu allow you to monitor different temperature readings in the tank along with adjusting the Operating Set Point and Differential . ...

  • A.O. Smith 500A - page 22

    22 4. Changing the Display Units The display interface to the heater has the option of selecting between degrees and Fahrenheit and degrees Celsius for temperature displays. This can be found in the "Display Settings" menu. Also in this menu, you may adjust how the backlight operates and the contrast of the LCD screen. 5. Fault and W arni ...

  • A.O. Smith 500A - page 23

    23 • Faults: This is a safety related condition that has been detected by the heater . NOTE: When these conditions occur , the water heater will not continue any further heating cycles and the water will no longer be heated until the condition is corrected and, in most cases, power has been cycled. Example of a Fault: Advanced Diagnostics Informa ...

  • A.O. Smith 500A - page 24

    24 7. V iewing the Fault History The controller for this water heater will store a history of ten of the last Fault and W arning conditions that occurred. This is stored in the Fault History . Along with all the information about the fault, including a estimate time of when the fault occurred, information regarding the advanced diagnostics for that ...

  • A.O. Smith 500A - page 25

    25 DO N OT U SE T HIS HEA TER IF ANY PAR T HA S BE EN U NDER WA T E R . IM ME D I A TE L Y C AL L A Q UA L I F IE D S E RV ICE T E C HN ICI A N TO INSP EC T THE HEAT ER AND TO RE PL AC E ANY PART OF THE CO NTR OL SYS TE M AND ANY GAS CON TR OL WHI CH HAS BEEN UND ER W ATE R. LIGHT THE UNIT IN ACCORDANCE WITH THE OPERA TING INSTRUCTIONS LABEL A TT A ...

  • A.O. Smith 500A - page 26

    26 c. Remove the pressure regulator cover screw (Figure 16) and adjust the pressure by turning the adjusting screw with a small screwdriver . In this example, with heater running on natural gas, do not exceed 4.0" (0.996 kPa) W ater Column. Clockwise to increase gas pressure and input rate. Counterclockwise to decrease gas pressure and input r ...

  • A.O. Smith 500A - page 27

    27 W ARNING UNDER NO CIRCUMST ANCES SHOULD THE INPUT EXCEED THE RA TE SHOWN ON THE HEA TER RA TING PLA TE. OVERFIRING COULD RESUL T IN DAMAGE OR SOOTING OF THE HEA TER. CA THODIC PROTECTION CAUTION HYDROGEN GAS CAN BE PRODUCED IN A HOT WATER SYSTEM SERVED BY THIS HEATER THAT HAS NOT BEEN USED FOR A LONG PERIOD OF TIME (GENERALLY TWO WEEKS OR MORE). ...

  • A.O. Smith 500A - page 28

    28 FLUSHING 1. T urn off the heater electrical disconnect switch. 2. Open the drain valve and allow water to ow until it runs clean. 3. Close the drain valve when nished ushing. 4. T urn on the heater electrical disconnect switch. DRAINING The heater must be drained if it is to be shut down and exposed to freezing temperatures. Maintenance ...

  • A.O. Smith 500A - page 29

    29 POWERED ANODE SYSTEM T o insure a long, trouble-free operating life, BTH 300, 400 and 500 are factory equipped with a powered anode system. The anodes are of a permanent design and do not need replacing unless damaged. DRAIN V AL VE AND ACCESS P ANELS The heaters are equipped with a 3/4" drain valve. An access panel covers the cleanout open ...

  • A.O. Smith 500A - page 30

    30 ONE TEMPERA TURE - ONE HEA TER HORIZONT AL ST ORAGE T ANK FORCED CIRCULA TION WITH OR WITHOUT BUILDING RECIRCULA TION DANGER TEMPERA TURE SETTING SHOULD NOT EXCEED SAFE TEMPERA TURE A T FIXTURES. SEE WA TER TEMPERA TURE CONTROL WARNING ON P AGE 3 . I F H IG H ER P RE H EAT T EM P ER ATU RE S AR E NECESSARY TO OBT AIN ADEQUA TE BOOSTER OUTPUT , A ...

  • A.O. Smith 500A - page 31

    31 * PIPE RELIEF V AL VE T O OPEN DRAIN. NOTE: IF TEMPERED WA TER IS RECIRCULA TED, RETURN LINE SHOULD BE CONNECTED A T POINT “A”. INST ALL IN ACCORDANCE WITH LOCAL CODES. TWO TEMPERA TURE - ONE HEA TER HIGH TEMPERA TURE WITH OR WITHOUT BUILDING RECIRCULA TION DANGER TEMPERA TURE SETTING SHOULD NOT EXCEED SAFE TEMPERA TURE A T FIXTURES. SEE WA ...

  • A.O. Smith 500A - page 32

    32 TWO TEMPERA TURE - TWO HEA TERS HIGH TEMPERA TURE WITH OR WITHOUT BUILDING RECIRCULA TION TWO TEMPERA TURE - THREE HEA TERS (TWO PRE-HEA TERS/ONE BOOSTER HEA TER) WITH OR WITHOUT BUILDING RECIRCULA TION MUST BE IDENTICAL HEA TERS FOR MUL TIPLE HEA TER INST ALLA TION SEE MANIFOLD KIT SPECIFICA TIONS, P AGE 35. CAUTION : IF BUILDING COLD WA TER SU ...

  • A.O. Smith 500A - page 33

    33 * PIPE RELIEF V AL VE TO OPEN DRAIN ** 140°F (60°C)TO 150°F (66°C) SHOULD BE MAXIMUM W A TER TEMPERA TURE MAINT AINED IN THE PRE-HEA TERS. 120°F (49°C) SHOULD BE THE MINIMUM TEMPERA TURE OF W A TER IN THE PRE-HEA TERS. CONNECT CIRCULA TING LINE FROM FIXTURES, IF USED, TO COLD W A TER SUPPL Y LINE OF PRE-HEA TER. CONNEC T CIRCU LA TING LINE ...

  • A.O. Smith 500A - page 34

    34 NOTE 1: TOGGLE SWITCH CONTROLS 180°F (82°C) W A TER CIRCULA TION. INST ALL ON OR CLOSE TO DISHWASHER. TO GGLE SWITCH MUST BE CLOSED (ON) DURING THE RINSE OPERA TION AND OPEN (OFF) WHEN DISHWASHER IS NOT OPERA TING OR WHEN ON LONG ST ANDBY . NOTE 2: INST ALL LINE TEMPERA TURE CONTROL IN AN UNINSULA TED TEE BEYOND THE DISHWASHER T AKEOFF IN T HE ...

  • A.O. Smith 500A - page 35

    35 MUL TIPLE UNIT INST ALLA TIONS Proper installation of multiple water heaters assures water ow balance of all units. Without this balance, the full water heating and storage potential of the system cannot be achieved. Plus, the units with the higher water ow may have a shortened life. Dimensions shown are for minimum space occupied by the w ...

  • A.O. Smith 500A - page 36

    36 C H E C K L I S T A N D S E R V I C E I N F O R M A T I O N IMPORT ANT The installer may be able to observe and correct certain problems which might arise when the unit is put into operation or when it is re-red after a prolong ed shutdown. HOWEVER, it is recommended that only qualied servicemen, using appropriate test equipment , be allow ...

  • A.O. Smith 500A - page 37

    37 Checking these four (4) items rst will often result in a timely solution to the service call. W ARNING JUMPING OUT COMPONENTS AND/OR CIRCUITS DURING TROUBLESHOOTING CAN CAUSE SERIOUS PROBLEMS WITH THE UNIT’S OPERA TING SEQUENCE AND IGNITION SAFETY . IF YOU DO NOT HA VE THE PROPER TEST EQUIPMENT , I.E. A VOL T -OHM METER AND A MICROMETER, DO ...

  • A.O. Smith 500A - page 38

    38 NOTE: Always turn off and disconnect main supply wiring before servicing the unit. 4. Check connecting wire to the ame sensor . V erify that the ame sensor has not been damaged in any way . 5. V erify tha t the air supply is adeq uate . The air inle t scree n or blow er wheel may be restricted. Also, check the installation for proper venti ...

  • A.O. Smith 500A - page 39

    39 Model BTH Limited W arranty A. O. Smith Corporation, the warrantor , extends the following LIMITED W ARRANTY to the owner of this water heater . 1. THE T ANK If the glass-lined tank in this water heater shall prove upon examination by the warrantor to have leaked due to natural corrosion from potable water therein, during the rst THREE years ...

  • A.O. Smith 500A - page 40

    40 www .hotwater .com ...

メーカー A.O. Smith カテゴリー Water Heater

A.O. Smith 500Aのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 500Aの取扱説明書
- A.O. Smithの製品カード
- パンフレット
- またはA.O. Smith 500Aの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、A.O. Smith 500Aの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、A.O. Smith 500Aの取り付け説明書、サービスマニュアル、簡易説明書、またはA.O. Smith 500Aのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、A.O. Smith 500Aの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

A.O. Smith 500Aデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがA.O. Smith 500Aを使用するのを助ける技術的文書のことです。説明書は通常、全てのA.O. Smith 500Aユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

A.O. Smithの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. A.O. Smith 500Aの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははA.O. Smith 500Aの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。A.O. Smith 500Aに関してこのドキュメントで見つけることができる全てのヒントの目次
3. A.O. Smith 500Aデバイスの基本機能を使うにあたってのヒント。 A.O. Smith 500Aのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。A.O. Smith 500Aに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるA.O. Smith 500Aのメーカー/サービスへの連絡先に関する情報。

A.O. Smith 500Aについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもA.O. Smith 500Aの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがA.O. Smith 500Aで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)