  • Linear LRA - page 1

    LRA Linear Residential Actuator Installation Guide PRINTER’S INSTRUCTIONS: INSTR,INSTL,LRA - LINEAR P/N: 228158 X12 - INK: BLACK - MA TERIAL: 20 LB. MEAD BOND - SIZE: 8.500” X 11.000” - SCALE: 1-1 - FOLDING: ALBUM-FOLD - BINDING: SADDLE-STITCH C US I N T E R T E K CM L I S T E D Operator models contained in this manual conform to UL325 standa ...

  • Linear LRA - page 2

    LRA Linear Residential Actuator Installation Guide - 2 - 228158 Revision X13 2-3-2009 T able of Contents Pre-installation Information .................................. 1 B e f o r e Y o u B e g i n . . . ...................................... 1 Alwa ys Check the Gate’ s Action . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Gate Operat ...

  • Linear LRA - page 3

    LRA Linear Residential Actuator Installation Guide - 1 - 228158 Revision X13 2-3-2009 Pre-installation Information Before Y ou Begin... Bef ore unpac king, inspect the carton for e xterior damage. If you find damage, advise the deliv er y carrier of a potential claim. Inspect your package carefully . Y ou can check your accessor y box par ts with ...

  • Linear LRA - page 4

    LRA Linear Residential Actuator Installation Guide - 2 - 228158 Revision X13 2-3-2009 Linear Actuator Operator Overview The Model LRA Residential Linear Actuator is designed to open and close a light-duty residential s wing gate. The operator can be used in left-hand or right-hand swing gate installations on gates weighing up to 600 pounds . The op ...

  • Linear LRA - page 5

    LRA Linear Residential Actuator Installation Guide - 3 - 228158 Revision X13 2-3-2009 Gate Lay out Illustration ENTR Y GATE FULLY CLOSED GATE FULLY OPEN LEAVE SLAC K IN CABLE TO ALLOW F O R GATE SWIN G 1/2 GATE HEIGHT CONTRO L BO X CONTRO L BO X GATE TOP VIEW GATE BACK SIDE VIEW 36" RECOMME NDE D MINIMUM BAC KSPAC E 8" FROM CENTER OF GATE ...

  • Linear LRA - page 6

    LRA Linear Residential Actuator Installation Guide - 4 - 228158 Revision X13 2-3-2009 Mounting Brack et Installation Examine Figure 2 f or details of the required mounting locations f or the two brack ets. The brack ets must be mounted at the co rr ec t lo ca ti on s to all o w th e op er ator to ope n th e ga te at a 90 degree angle and to ensure ...

  • Linear LRA - page 7

    LRA Linear Residential Actuator Installation Guide - 5 - 228158 Revision X13 2-3-2009 Operator Setup Operator Mounting The operator mounts on the post brack et pin and into the gate brac ket b ushing. Refer to Figure 5. With the gate closed, carefully position the operator over the mounting 1. brac kets . Low er the operator onto the post brack et ...

  • Linear LRA - page 8

    LRA Linear Residential Actuator Installation Guide - 6 - 228158 Revision X13 2-3-2009 Operator Setup (Continued) Limit Switch Adjustment The open and close limit switches are adjustable by sliding them on the operator’ s frame . Sliding either s witch closer to the center of the operator decreases the gate tra vel. T o limit the 1. opening tra ve ...

  • Linear LRA - page 9

    LRA Linear Residential Actuator Installation Guide - 7 - 228158 Revision X13 2-3-2009 Controller Features SHADOW/RESET PROGRAMMING BUTTONS POWE R INDICATORS DISPLAY WHIP ANTENNA OPERATION BUTTONS OPERATION AND PROGRAMMING INDICATORS ANTENNA CONNECTOR MOTOR BOAR D COVE R INPU T POWE R TERMINALS ACCESSORY POWE R TERMINALS RESET BUTTON TERMINALS SOLA ...

  • Linear LRA - page 10

    LRA Linear Residential Actuator Installation Guide - 8 - 228158 Revision X13 2-3-2009 Indicator Descriptions INDICA T OR DEFINITION INDICA TION WHEN LIT DURING NORMAL OPERA TION INDICA TION WHEN LIT DURING PROGRAMMING OPERA TION PROGRAMMING 24 VOL T INPUT PO WER LOW VOL T A GE AC PO WER IS PRESENT 24 VOL T DC A CCY POWER LO W VOL T A GE DC POWER IS ...

  • Linear LRA - page 11

    LRA Linear Residential Actuator Installation Guide - 9 - 228158 Revision X13 2-3-2009 T erminal Descriptions TERMINAL GROUP FUNCTION A C N 24 VOL T INPUT F ACT OR Y CONNECTED TO 24 V AC FR OM TRANSFORMER OR 24 VDC FROM CONTINUOUS DUTY DC SUPPL Y . AC DC - A CCESSOR Y POWER PRO VIDES 24 VOL T DC POWER FOR A CCESSORIES. (.5A MAX) DC + RESET RESET BUT ...

  • Linear LRA - page 12

    LRA Linear Residential Actuator Installation Guide - 10 - 228158 Revision X13 2-3-2009 Operator Accessor y Connections 3-BUTTON ST ATIO N KEYSWITC H FIRE ACCESS SWITCH SINGLE-CHAN NEL RADIO RECEIVER WIRELESS GA TE EDGE SE NSOR MG T TRANSMITTE R PHOTOEYE FO R REVERS E PHOTOEYE FO R OPEN OBS TRUCTIO N TELEPHONE E NTR Y KEYPAD EXTERNAL POWE R SOLENOID ...

  • Linear LRA - page 13

    LRA Linear Residential Actuator Installation Guide - 11 - 228158 Revision X13 2-3-2009 Basic Controller Programming Progr amming Overview The Controller can be programmed with v arious options for the operator . The programming fields are defined as “functions” that hav e “options”. T o make setup easier for the installer , the Controller ...

  • Linear LRA - page 14

    LRA Linear Residential Actuator Installation Guide - 12 - 228158 Revision X13 2-3-2009 Basic Controller Programming (Cont.) Run Alarm and Pre-start Alarm The f actor y def ault is Run Alarm on and a 3-second Pre-star t Alarm. The operator’ s beeper will sound 3 seconds before the operator star ts. The options are: Run Alarm Off and Pre-start Alar ...

  • Linear LRA - page 15

    LRA Linear Residential Actuator Installation Guide - 13 - 228158 Revision X13 2-3-2009 Advanced Controller Progr amming Entering Advanced Progr amming Mode T o access and program the Advanced Programming functions, f or each programming session, Adv anced Programming must be enab led. After exiting programming, the Advanced Programming functions wi ...

  • Linear LRA - page 16

    LRA Linear Residential Actuator Installation Guide - 14 - 228158 Revision X13 2-3-2009 Advanced Controller Progr amming (Cont.) Auxiliary Relay Mode The Auxiliary Relay has nor mally open and nor mally closed contacts. The f actor y setting disables the A uxiliar y Relay . The rela y can be set f or : Magloc k: • The rela y will energize dur i ...

  • Linear LRA - page 17

    LRA Linear Residential Actuator Installation Guide - 15 - 228158 Revision X13 2-3-2009 Advanced Controller Progr amming (Cont.) Soft Start/Stop Duration This function causes the operator to star t and stop the DC motor slowly reducing gate wear and tear (at the full open or closed positions only). The factory default sets the Soft Star t/Stop Durat ...

  • Linear LRA - page 18

    LRA Linear Residential Actuator Installation Guide - 16 - 228158 Revision X13 2-3-2009 Advanced Controller Progr amming (Cont.) Radio Enable The Controller contains a built-in MegaCode ® radio receiver to allow activation from up to 40 access control transmitters and two Model MGT (gate edge) transmitters. The factory def ault enables the inter na ...

  • Linear LRA - page 19

    LRA Linear Residential Actuator Installation Guide - 17 - 228158 Revision X13 2-3-2009 Loop Lay out Illustration 2" 3/8" 4 FT. MINIMU M USE RELIEF CUT S AT CORNER S TWIST WIRE FROM END OF LOOPS BACK TO OPERATOR AT LEAST SIX TIMES PE R FOOT 2" MAX. LOOP SEALANT MULTIPLE TURN S REFER TO LOOP INSTALLATION NOTE S FOR DETAIL S OPEN GATE P ...

  • Linear LRA - page 20

    LRA Linear Residential Actuator Installation Guide - 18 - 228158 Revision X13 2-3-2009 Safety Edge Lay out Illustration RECEIVER FOR GATE EDGE TRANS MITTER BUILT INTO CONTROLLER GATE EDGE TRANSMITTER #1 SEPARATE PEDESTRIAN GATE REQUIRED 7FT. MINIMUM DISTANCE AWAY FROM GATE EDGE MOUNTED ON LEADING OUTSIDE EDGE OF GATE EDGES MOUNTED ACROSS BOTTOM OF ...

  • Linear LRA - page 21

    LRA Linear Residential Actuator Installation Guide - 19 - 228158 Revision X13 2-3-2009 Photoey e Installation Illustration SEPARATE PEDESTRIAN GATE REQ UIRED 7 FT. MINIMUM DISTANCE AWAY FROM GATE OBSTRUCTION DETECTING APPLIC ATIO N (WIRE TO CLOSE OBSTRUCTION) OBSTRUCTION DETECTING APPLIC ATIO N (WIRE TO OPEN OBSTRUCTION) PHOTOEYE REVERSE APPLICATIO ...

  • Linear LRA - page 22

    LRA Linear Residential Actuator Installation Guide - 20 - 228158 Revision X13 2-3-2009 Dual Gate Installations T wo oper ato rs can be used in du al gat e inst all ati ons . T he ope ra tor s communicate with each other through the 3-wire COMM LINK terminals. When one operator activates , the COMM LINK connection signals the other operator to activ ...

  • Linear LRA - page 23

    LRA Linear Residential Actuator Installation Guide - 21 - 228158 Revision X13 2-3-2009 Operation Indications During nor mal oper ation, the Controller’ s displa ys will indicate current operating conditions and status . P ower -up Displa y When the Controller powers up, dashes will show on the displa y for one second, then the fir mware version ...

  • Linear LRA - page 24

    LRA Linear Residential Actuator Installation Guide - 22 - 228158 Revision X13 2-3-2009 T roubleshooting Contacting T echnical Support F or technical questions regarding Linear gate operators, contact the T echnical Ser vices Depar tment at: 1-800-421-1587 from 6:30 AM to 4:30 PM P acific time Operator fails to start A. Make sure you ha ve pow er a ...

  • Linear LRA - page 25

    LRA Linear Residential Actuator Installation Guide - 23 - 228158 Revision X13 2-3-2009 Model LRA Replacement P arts HARDWARE KI T POST BRACKET KI T GATE BRACKE T KI LIMIT SWITCH KIT T WORM DRIVE CA P , TRAVELER, & G ATE BRACKET KI T KIT #3 KIT #5 90 28 1 2 28 91 KIT #4 63 17 101 27 65 44 KIT #1 KIT #2 101 17 26 64 99 17 101 99 92 94 95 96 25 97 ...

  • Linear LRA - page 26

    LRA Linear Residential Actuator Installation Guide - 24 - 228158 Revision X13 2-3-2009 Prev entative Maintenance General Linear gate operators are designed for many y ears of trouble-free operation and, under recommended operating conditions, will require only minimal maintenance. T o ensure that a unit is ready f or operation at all times, and to ...

  • Linear LRA - page 27

    LRA Linear Residential Actuator Installation Guide - 25 - 228158 Revision X13 2-3-2009 ...

  • Linear LRA - page 28

    LRA Linear Residential Actuator Installation Guide - 26 - 228158 Revision X13 2-3-2009 Gate Operator Installation Checklist ❑ ❑ 1. The gate has been chec ked to make sure it is le vel and mov es freely in both directions. ❑ ❑ 2. P otential pinch areas have been guarded so as to be inaccessib le OR hav e contact and/or non-contact obstructio ...

メーカー Linear カテゴリー Automobile Electronics

Linear LRAのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- LRAの取扱説明書
- Linearの製品カード
- パンフレット
- またはLinear LRAの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Linear LRAの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Linear LRAの取り付け説明書、サービスマニュアル、簡易説明書、またはLinear LRAのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Linear LRAの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Linear LRAデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがLinear LRAを使用するのを助ける技術的文書のことです。説明書は通常、全てのLinear LRAユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Linearの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Linear LRAの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははLinear LRAの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Linear LRAに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Linear LRAデバイスの基本機能を使うにあたってのヒント。 Linear LRAのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Linear LRAに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるLinear LRAのメーカー/サービスへの連絡先に関する情報。

Linear LRAについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもLinear LRAの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがLinear LRAで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (1)

giorgio

tempo di ricarica? indice di piena ricarica totale