    UE08/UE10/UE12 (04/07) 230 Volts UE10:Staring with serial number LGDK00001 UE12:Staring with serial number LGDK00001 Thru-the-Wall Series Thru-the-Wall Series Ser vice and P ar ts Ma nual 115 Volts UE08: Staring with serial number LGCK00001 ...

  • Friedrich UE12 - page 2

    —2— 1. PREF A CE 1.1 SAFETY PRECAUTIONS ...............................2 1.2 INSULATION RESISTANCE TEST.................2 1.3 SPECIFICATIONS ..........................................3 1.4 FEATURES .....................................................4 1.5 CONTROL LOCATIONS .................................4 2. DISASSEMBL Y INSTR UCTIONS 2.1 ME ...

  • Friedrich UE12 - page 3

    —3— 1.3 SPECIFICA TIONS 1.3.1 FOR UE08A13B/UE10A33B/UE12A33B REMARK POWER SUPPLY CAPACITY (Btu/h) INPUT (W) RUNNING CURRENT (A) E.E.R. (Btu/W.h) CAPACITY (Btu/h) INPUT (W) RUNNING CURRENT (A) INDOOR (°C) OUTDOOR (°C) INDOOR (°C) OUTDOOR (°C) REFRIGERANT (R-22) CHARGE(g) EVAPORATOR CONDENSER FAN, INDOOR FAN, OUTDOOR FAN SPEEDS (FAN/COOLING/H ...

  • Friedrich UE12 - page 4

    1.4 FEA TURES • Designed for cooling only. • Powerful and quiet cooling. • Top-down chassis for the simple installation and service. 1.5 CONTR OL LOCA TIONS • Built in adjustable THERMISTOR and THERMOSTAT. • Washable one-touch filter. • Compact size. • VENTILA TION Push the lever to the "CLOSE" position to cool, heat or reci ...

  • Friedrich UE12 - page 5

    —5— 2.1 MECHANICAL P AR TS 2.1.1 FRONT GRILLE 1. Open the inlet grille downward. 2. Remove the screw which fastens the front grille. 3. Pull the front grille from the right side. 4. Remove the front grille. (See Fig. 1) 5. Re-install the component by referring to the removal procedure. 2.1.2 CABINET 1. After disassembling the FRONT GRILLE, remo ...

  • Friedrich UE12 - page 6

    Figure 7 —6— 2.2 AIR HANDLING P AR TS 2.2.1 ORIFICE, HEA TER ASSY AND TURBO F AN 1. Remove the front grille. (Refer to section 2.1.1) 2. Remove the cabinet. (Refer to section 2.1.2) 3. Remove the 2 screws which fasten the evaporator at the left side and the right side. (See Fig. 4) 4. Move the evaporator sideward carefully. 5. Remove the 2 term ...

  • Friedrich UE12 - page 7

    —7— 2.2.3 SHROUD 1. Remove the fan. (Refer to section 2.2.2) 2. Remove the screw which fastens the shroud. 3. Remove the shroud. (See Fig. 9) 4. Re-install the components by referring to the removal procedures, above. 2.3 ELECTRICAL P AR TS 2.3.1 MO T OR 1. Remove the cabinet. (Refer to section 2.1.2) 2. Remove the clamp cord and disconnect the ...

  • Friedrich UE12 - page 8

    —8— 2.3.4 PO WER CORD 1. Remove the control box. (Refer to section 2.1.3) 2. Unfold the control box. (Refer to section 2.3.3) 3. Disconnect the grounding screw from the control box. 4. Disconnect 2 receptacles. 5. Remove a screw which fastens the clip cord. 6. Pull the power cord. (See Fig. 13) 7. Re-install the components by referring to the r ...

  • Friedrich UE12 - page 9

    —9— 2.4 REFRIGERA TION CYCLE 2.4.1 CONDENSER 1. Remove the cabinet. (Refer to section 2.1.2) 2. Remove the brace and the shroud cover. (Refer to section 2.2.1) 3. Remove the 5 screws which fasten the condenser. 4. After discharging the refrigerant completely into a Freon TM Recovery System, unbraze the interconnecting tube at the condenser conn ...

  • Friedrich UE12 - page 10

    —10— — Replacement of the refrigeration cycle. 1. When replacing the refrigeration cycle, be sure to discharge the refrigerant system using a Freon TM recovery System. Install a valve for the recovery before venting the Freon. Remove the valve when finished. 2. After discharging the unit completely, remove the desired component, and unbrace t ...

  • Friedrich UE12 - page 11

    —11— Equipment needed: Vacuum pump, Charging cylinder, Manifold gauge, Brazing equipment. Pinch-off tool capable of making a vapor-proof seal, Leak detector, Tubing cutter, Hand Tools to remove components, Service valve. A COMPOUND GAUGE EVAPORATOR (LOW PRESSURE SIDE) COMPRESSOR CAPILLARY TUBE CONDENSER (HIGH PRESSURE SIDE) SEE INSETS BELOW MAN ...

  • Friedrich UE12 - page 12

    — 12 — 3. TR OUBLESHOO TING GUIDE 3.1 OUTSIDE DIMENSIONS 19- 21 / 32 " (499mm) 24- 21 / 32 " (626mm) 14- 13 / 32 " (366mm) CONDENSER COILS EV APORA T OR COILS FA N M OTO R : REFRIGERANT FLOW TURBO F AN CAPILLAR Y TUBE COMPRESSOR 3.2 PIPING SYSTEM Following is a brief description of the important components and their functions in ...

  • Friedrich UE12 - page 13

    — 13 — 3.3 TR OUBLESHOO TING GUIDE In general, possible trouble is classified in two causes. The one is called Starting Failure which is caused from an electrical defect, and the other is Ineffective Air Conditioning caused by a defect in the refrigeration circuit and improper application. Unit is running but cooling is ineffective Ineffective ...

  • Friedrich UE12 - page 14

    — 14 — Fails to Start Check circuit break er and fuse. Gas leakage at f eeler bulb of ther mostat Check control s witch. Only f an fails to start. Improper wiring. Def ect of fan motor capacitor . Irregular motor resistance ( ). Irregular motor insulation ( ). Replacement of f an motor Regular but f ails to star t Replacement of compressor (loc ...

  • Friedrich UE12 - page 15

    — 15 — — 15 — COMPLAINT CAUSE REMEDY Check voltage at outlet. Correct if none. Check voltage to rotary switch. If none, check power supply cord. Replace cord if circuit is open. Check switch continuity. Refer to wiring diagram for terminal identification. Replace switch if defective. Connect wire. Refer to wiring diagram for terminal identi ...

  • Friedrich UE12 - page 16

    — 16 — NAME PLATE RATING MINIMUM MAXIMUM 115V 103.5V 126.5V 208/230V 187V 253V COMPLAINT CAUSE REMEDY Check voltage. See the limits at the bottom of this page. If not within limits, call an electrician. Check the wire connections, if loose, repair or replace the terminal. If wires are off, refer to wiring diagram for identification, and replace ...

  • Friedrich UE12 - page 17

    — 17 — COMPLAINT CAUSE REMEDY Check the voltage. See the limits on the preced- ing page. If not within limits, call an electrician. Check overload, if externally mounted. Replace if open. (If the compressor temperature is high, remove the overload, cool, and retest.) If not running, determine the cause. Replace if required. Remove the cabinet. ...

  • Friedrich UE12 - page 18

    — 18 — 4. SCHEMA TIC DIA GRAM 4.1 CIRCUIT DIA GRAM • MODEL : UE08A13B/UE10A33B/UE12A33B 6411A20056L 6411A20056Q 2H00598F 4681A20044H 4681A20041C 4681A20041M 0CZZA20012A 6120AR2359E 2H01127D 6750A30001N 6750U-L028A 6750U-L058A 5300A20003B  5300A20003A NO. 1 2 3 4 5 7 8 Q'TY PER SET 1 1 1 1 1 1 1 RE- MARKS DESCRIPTION POWER COR ...

  • Friedrich UE12 - page 19

    — 19 — 5. EXPLODED VIEW • MODEL: UE08A13B/UE10A33B/UE12A33B 753011 W48602 559010 346811 349600 567502 349001 130410 W48602 137215 149410 W0CZZ 264110 130900 135312 147581 147582-2 147582-1 352390 148000 550140 149980 359012 266003 269310 152302 135313 E D F A G C B 749180 435301 ' F T IM E R P O W E R M O D E T E M P F A N S PE E D F 1 L ...

  • Friedrich UE12 - page 20

    — 20 — 6. REPL A CEMENT P A R TS LIST R: Service Parts N: Non Service parts LocNo FRD P/NO DESCRIPTION REMARK W0CZZ 67300725 CA PA CITOR, DRAWING R 266003 67300502 SWITCH, RO TA RY R 269310 67300404 THERM OST A T AS SEM BLY R 130410 67302923 BA SE A SSEMBLY, SINGLE R 130900 67303705 CA BINET R 135313 67306104 G RILLE, INLET R 135312 67306006 GR ...

  • Friedrich UE12 - page 21

    LocNo FRD P/NO DESCRIPTION REMARK 266003 67300502 SWITCH, RO TA RY R 269310 67300404 THERM OST A T AS SEM BLY R 130410 67302919 BA SE A SSEMBLY, SINGLE R 130900 67303705 CA BINET R 135313 67306104 GRILLE, INLET R 135312 67306005 GRILLE A SSEMBLY , FRONT (SINGLE) R 137215 67305504 PA NEL A SSEMBLY, CONT ROL R W48602 67302500 CLA M P, SPRING R 346811 ...

  • Friedrich UE12 - page 22

    LocNo FRD P/NO DESCRIPTION REMARK 130410 67302921 BA SE A SSEMBLY, SINGLE R 130900 67303705 CA BINET R 135312 67306005 GRILLE A SSEMBLY , FRONT (SINGLE) R 135313 67306104 GRILLE, INLET R 137215 67305504 PA NEL A SSEMBLY, CONT ROL R 147581 67306203 LOUVER, HORIZONT A L R 147582-1 67306252 LOUVER, VERTICA L R 147582-2 67306253 LOUVER, VERTICA L R 148 ...

  • Friedrich UE12 - page 23

    UE08/UE10/UE12 (06/07) Printed in China Post Office Box 1540 • 4200 N. Pan Am Expressway • San Antonio, Texas 78295-1540 • (210) 357-4400 • FAX (210) 357-4480 FRIEDRICH AIR CONDITIONING CO. Visit our web site at www.friedrich.com P/NO.:3828A20040L ...

メーカー Friedrich カテゴリー Air Conditioner

Friedrich UE12のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- UE12の取扱説明書
- Friedrichの製品カード
- パンフレット
- またはFriedrich UE12の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Friedrich UE12の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Friedrich UE12の取り付け説明書、サービスマニュアル、簡易説明書、またはFriedrich UE12のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Friedrich UE12の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Friedrich UE12デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがFriedrich UE12を使用するのを助ける技術的文書のことです。説明書は通常、全てのFriedrich UE12ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Friedrichの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Friedrich UE12の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははFriedrich UE12の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Friedrich UE12に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Friedrich UE12デバイスの基本機能を使うにあたってのヒント。 Friedrich UE12のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Friedrich UE12に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるFriedrich UE12のメーカー/サービスへの連絡先に関する情報。

Friedrich UE12についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもFriedrich UE12の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがFriedrich UE12で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)