  • Emerson CF980MAB 00 - page 1

    READ AND SA VE THESE INSTRUCTIONS Model No. CF980MAB 00 CF980MBX 00 EMX TUREEN ™ Part No. F40BP73530000 Form No. BP7353 U.L. Model No.: CF980 Net Weight: 35.8 Lbs. Damp Loca tion Ceiling F an Owner's Manual LIMITED WARRANTY What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceili ...

  • Emerson CF980MAB 00 - page 2

    2 WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference 2 . Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally ...

  • Emerson CF980MAB 00 - page 3

    T ools Needed for Assembly One Phillips head screwdriver One stepladder MA TERIALS Wiring, outlet box and box connectors must be of type required by the local code. The minimum wire would be a 3-conductor (2-wire with ground) of the following sizes: Unpac king Instr uctions For your convenience, check-off boxes are provided next to each step. As ea ...

  • Emerson CF980MAB 00 - page 4

    4 Electrical R equir ements Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit. The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds. To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked “Acceptable for Fa ...

  • Emerson CF980MAB 00 - page 5

    5 CAUTION: Before installing and tightening the screws, be sure there are no wires pinched between the bottom of the light kit assembly and fan motor. 5. Install the three #10-24 x 5/16” pan head screws to secure the light kit assembly to the lower housing (Figure 4). #10-24 x 5/16" P AN HEAD SCREW (3) LIGHT KIT ASSEMBL Y LOWER HOUSING Figur ...

  • Emerson CF980MAB 00 - page 6

    6 12. Position one of the blade assemblies onto the motor hub and secure blade assembly using two 1/4-20 x 1/2” oval head flange screws (provided). Repeat for all blade assemblies (Figure 8). 13. Slide the coupler cover over the downrod and position it to cover the motor coupling (Figure 9). 14. Position the ceiling cover over the downrod. Be sur ...

  • Emerson CF980MAB 00 - page 7

    7 2. Carefully lift the fan and seat the hanger ball/down- rod assembly on the hanger bracket that was just attached to the outlet box (Figure 13). Be sure the groove in the ball is lined up with the tab on the hanger bracket (Figure 12). Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard. WARNING ...

  • Emerson CF980MAB 00 - page 8

    8 OUTLET BOX BLACK SUPPL Y WIRE BLACK/WHITE RECEIVER WIRE BLACK F AN WIRE BLUE F AN WIRE BLUE RECEIVER WIRE YELLOW RECEIVER WIRE DO NOT USE CEILING COVER WHITE RECEIVER WIRE WHITE F AN WIRE WIRE CONNECTOR RECEIVER WHITE SUPPL Y WIRE SUPPL Y GROUND WIRE (GREEN OR BARE) HANGER BALL GROUND WIRE (GREEN) HANGER BRACKET GROUND WIRE (GREEN) HANGER BRACKET ...

  • Emerson CF980MAB 00 - page 9

    9 HANGER BRACKET OUTLET BOX RECEIVER CEILING COVER Figure 16 YELLOW RECEIVER WIRE DO NOT USE DOWNROD WHITE SUPPL Y WIRE BLACK F AN WIRE SW105 RECEIVER TO 110V SUPPL Y WHITE F AN WIRE BLUE RECEIVER WIRE BLUE F AN WIRE BLACK SUPPL Y WHITE RECEIVER WIRE BLACK RECEIVER WIRE BLACK/WHITE RECEIVER Check to see that all connections are tight, including gro ...

  • Emerson CF980MAB 00 - page 10

    2. Place the glass onto the light kit assembly aligning the three flat areas on the top flange of the glass with the three pins on the inside of the assembly (Figure 19). Then turn the glass clockwise until it stops turning. 3. Your ceiling fan is now installed and wire to be controlled by your remote control system. 10 50-WA TT MR-16, GU-10 HALOGE ...

  • Emerson CF980MAB 00 - page 11

    11 Setting Oper a ting F requency of W all Contr ol and R eceiv er (Figur e 20) Your wall control and receiver have code switches which must be set in one of 16 possible code combi- nations. The four levers (numbered 1, 2, 3, and 4) on the switches are factory-set in the ON (up) position. Change the switch settings as follows: 1. Slide the four swi ...

  • Emerson CF980MAB 00 - page 12

    12 AIRFLOW DIRECTION BUTTON LIGHT BUTTON FA N SPEED BUTTONS F AN OFF BUTTON RED INDICA TOR LIGHT FAN OFF LOW MED HI LIGHT REV Figure 23 T rouble Shooting W all Contr ol Fan/Light Fails to Operate • Check that the wall switch for the ceiling fan is in the “ON” position. • Check that the battery is good (red indicator light should light when ...

  • Emerson CF980MAB 00 - page 13

    13 INSTRUCTION T O THE USER (if device contains a digital device) This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interfer- ence in a residential installation. This equipment generates, us ...

  • Emerson CF980MAB 00 - page 14

    T rouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers. 2. Loose power line connections to the fan, or loose 2. Check line power connections to fan and switch wire switch wire connections in the switch housing. connections in the s ...

  • Emerson CF980MAB 00 - page 15

    15 R epair Par ts 9 HI HI MED MED LOW LOW F A N O F F R E V R E V L I G H T 1 5 6 7 3 2 10 4 8 11 16 17 19 18 23 14 20 21 12 13 15 24 22 ...

  • Emerson CF980MAB 00 - page 16

    Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant • St. Louis, MO 63136 Part No. F40BP73530000 Printed in China 10/07 Form No. BP7353 R epair Par ts Listing Part Numbers Key Model No. Model No. No. Description CF980MBX 00 CF980MAB 00 * Hanger Pack, Consisting of: 761655-67 761655-67 1 Hanger Bracket — — 2 Hanger Ball ? ...

メーカー Emerson カテゴリー Fan

Emerson CF980MAB 00のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- CF980MAB 00の取扱説明書
- Emersonの製品カード
- パンフレット
- またはEmerson CF980MAB 00の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Emerson CF980MAB 00の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Emerson CF980MAB 00の取り付け説明書、サービスマニュアル、簡易説明書、またはEmerson CF980MAB 00のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Emerson CF980MAB 00の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Emerson CF980MAB 00デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがEmerson CF980MAB 00を使用するのを助ける技術的文書のことです。説明書は通常、全てのEmerson CF980MAB 00ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Emersonの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Emerson CF980MAB 00の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははEmerson CF980MAB 00の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Emerson CF980MAB 00に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Emerson CF980MAB 00デバイスの基本機能を使うにあたってのヒント。 Emerson CF980MAB 00のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Emerson CF980MAB 00に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるEmerson CF980MAB 00のメーカー/サービスへの連絡先に関する情報。

Emerson CF980MAB 00についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもEmerson CF980MAB 00の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがEmerson CF980MAB 00で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)