    036-21004-002 Re v . B (0602) FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE SPLIT -SYSTEM AIR CONDITIONERS 14 SEER MODELS: FRCS024 THRU 060 (2 THRU 5 NOMINAL TONS) Due to continuo us product impr ovement, specifica tions are subjec t to change without notice . Visit us on the web at www .yo rk.com for the most up-to-date techni ...

  • York FRCS024 - page 2

    036-21004-002 Rev. B (0602 ) 2 Unitary Products Group Physical and Electr ical Dat a MODEL FRCS0241BD FRCS0301BD FRCS0361CD FRCS0421CE FRCS0481CE F RCS0601BF Unit Supply V oltage 208 / 230 - 1 – 60 Normal V oltage Range 1 187 to 252 Minimum Circuit Ampacity 12.1 14.9 18.1 17.8 20.6 31.8 Max Overcurrent Device Amps 2 20 20 25 30 35 50 Compressor T ...

  • York FRCS024 - page 3

    036-21004-002 Rev. B (0602) Unitary Products Group 3 - = Not applicable COOLING CAP ACITY - Wi th Air Handler Coils UNIT MODEL AIR HANDLER COIL 1 MODEL COOLING MODEL ELECTRIC 2 HEA T KW W RA TED CFM NET MBH SEER W/O TXV SEER + TXV 3 EER TOT AL SENS. 1 PH 14 SEER AC WITH N-AH / G2FD FRCS0241BD N1AHB0806 2,5,8,10 17 G2FD036S17 800 25.2 18.1 - 14.00 1 ...

  • York FRCS024 - page 4

    036-21004-002 Rev. B (0602 ) 4 Unitary Products Group COOLING CAP ACITY - Upflow , Downflow , & Horizont al Furnaces and Coils UNIT MODEL FURNACE** COIL MODEL COOLING CFM RANGE (MIN.-MAX.) W RA TED CFM NET MBH SEER + TXV W/O TDR SEER + TXV 1 + TDR* EER TOT AL S EN S. FRCS0241BD 700 900 14 G1F A036S1 4 800 25.0 18.0 13.85 - 12.30 17,21 G1F A036S ...

  • York FRCS024 - page 5

    036-21004-002 Rev. B (0602) Unitary Products Group 5 * Requires a 2FD Blower Time Delay unless a standard furnace is equipped with one. ** Refer to Quick Selection Chart for specific furnace match-up. FRCS0601BF 1650 2150 21,24 G1F A060S21,24 1900 53.5 37.1 - 13.25 12.00 24 G2FD060S24 1 900 53.5 37.1 - 13.25 12.00 24 G2FD061H24 2050 54.5 39.1 - 13. ...

  • York FRCS024 - page 6

    036-21004-002 Rev. B (0602 ) 6 Unitary Products Group 1. For condensing unit only . Does not include ef fe ct of evaporator motor power or heat. 2. Performance based on 1 5° superheat and 1 5° sub-cooling at condensing unit. a. Increa se capacit y 1% for e ach 2° in crease in sub-cool ing. b. Decrease capacity 1% for eac h 2° decrease in sub-co ...

  • York FRCS024 - page 7

    036-21004-002 Rev. B (0602) Unitary Products Group 7 TYPICAL INST ALLA TION TYPICAL FIELD WIRING MINIMUM 18” SERVICE ACCESS CLEARANCE ON ONE SIDE 60” OVERHEAD CLEARANCE 10” CLEARANCE COIL AREA WEA THERPROOF DISCONNECT SWITCH THERMOST A T TO FURNACE OR AIR HANDLER TERMINAL BLOCK NEC CLASS 1 WIRING NEC CLASS 2 WIRING TO INDOOR COIL SEAL OPENING ...

  • York FRCS024 - page 8

    036-21004-002 Rev. B (0602 ) 8 Unitary Products Group Multipliers for determining th e performance with other indoor sections . COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. FRCS0241BD INDOOR COIL MODEL NO. F2RP/F2FP036 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 1 100 1250 1350 ID DB 85 80 75 70 85 80 75 70 85 80 75 70 ID WB 72 67 62 57 72 6 ...

  • York FRCS024 - page 9

    036-21004-002 Rev. B (0602) Unitary Products Group 9 Multipliers for determining th e performance with other indoor sections . COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. FRCS0301BD INDOOR COIL MODEL NO. G1F A04 8S21, 24 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 800 1000 1200 ID DB 85 80 75 70 85 80 75 70 85 80 75 70 ID WB 72 67 62 57 72 ...

  • York FRCS024 - page 10

    036-21004-002 Rev. B (0602 ) 10 Unitary Products Group Multipliers for determining th e performance with other indoor sections . COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. FRCS0361 CD INDOOR COIL MODEL NO. G1F A04 8S21, 24 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 1000 1200 1400 ID DB 85 80 70 85 80 70 85 80 70 ID WB 72 67 57 72 67 57 72 ...

  • York FRCS024 - page 11

    036-21004-002 Rev. B (0602) Unitary Products Group 11 Multipliers for determining th e performance with other indoor sections . COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. FRCS0421CE INDOOR COIL MODEL NO. G1F A060S21,24 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 1300 1450 1550 ID DB 85 80 75 70 85 80 75 70 85 80 75 70 ID WB 72 67 62 57 72 ...

  • York FRCS024 - page 12

    036-21004-002 Rev. B (0602 ) 12 Unitary Products Group Multipliers for determining th e performance with other indoor sections . COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. FRCS0481 CE INDOOR COIL MODEL NO. G1F A06 0S21,24 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 1400 1600 1800 ID DB 85 80 70 85 80 70 85 80 70 ID WB 72 67 57 72 67 57 72 ...

  • York FRCS024 - page 13

    036-21004-002 Rev. B (0602) Unitary Products Group 13 Multipliers for determining th e performance with other indoor sections . COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. FRCS0601BF INDOOR COIL MODEL NO. G1F A06 0S21, 24 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 1600 1800 2000 ID DB 85 80 70 85 80 70 85 80 70 ID WB 72 67 57 72 67 57 72 6 ...

  • York FRCS024 - page 14

    036-21004-002 Rev. B (0602 ) 14 Unitary Products Group MA TCHING INDOOR COMPONEN TS G1UA 1/2 CASED UPFLOW G1HD HORIZONT AL DUCT G2FD* MUL TI-POSITION (UPFLOW , HORIZONT AL AND DOWNFLOW) * Available with factory installed horizontal drain p an. ADD-ON COILS - FOR FURNACE APPLICA TIONS G1NA UNCASED UPFLOW G1F A FULL CASED UPFLOW AIR HANDLERS - FOR NO ...

  • York FRCS024 - page 15

    036-21004-002 Rev. B (0602) Unitary Products Group 15 NOTES ...

  • York FRCS024 - page 16

    Subject to change without notice. Printed in U.S.A. 036-21004-002 Rev. B (0602) Copyright © by York International Corp. 2002. All rights reserved. Supersedes: 036-2100 4-002 Rev. A (0502) Unitary 5005 Norman Product Y ork OK Group Drive 73069 ...

Manufacturer York Category Air Conditioner

Documents that we receive from a manufacturer of a York FRCS024 can be divided into several groups. They are, among others:
- York technical drawings
- FRCS024 manuals
- York product data sheets
- information booklets
- or energy labels York FRCS024
All of them are important, but the most important information from the point of view of use of the device are in the user manual York FRCS024.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals York FRCS024, service manual, brief instructions and user manuals York FRCS024. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product York FRCS024.

Similar manuals

A complete manual for the device York FRCS024, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use York FRCS024 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of York FRCS024.

A complete York manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual York FRCS024 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the York FRCS024, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the York FRCS024, that we can find in the current document
3. Tips how to use the basic functions of the device York FRCS024 - which should help us in our first steps of using York FRCS024
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with York FRCS024
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of York FRCS024 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning York FRCS024?

Use the form below

If you did not solve your problem by using a manual York FRCS024, ask a question using the form below. If a user had a similar problem with York FRCS024 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)