Manual Finisar 10GBASE-LRM X2

10 pages 0.25 mb
Download

Go to site of 10

Summary
  • Finisar 10GBASE-LRM X2 - page 1

    © Finisar Corporation – October 2008 Rev B Page 1 Product Specification RoHS-6 Compliant 10GBASE-LRM X2 Transponder FTLX1341E2 PRODUCT FEATURES  Hot pluggable X2 MSA form factor  Total power consumption: 4.0 W maximum  RoHS-6 compliant (lead-free)  Temperature range 0°C to 70°C  Transmission distance up to 220m *  Uncooled 13 ...

  • Finisar 10GBASE-LRM X2 - page 2

    FTLX1341E2 Product Sp ecification – October 2008 © Finisar Corporation – October 2008 Rev B Page 2 I. Pin Description Signal Name Level I/O Pin No. Description Management and Monitori ng Por ts MDIO Open Drain (output) 1.2V CMOS (input) I/O 17 Management Data I/O. Re quires external 10 - 22 k Ω pull-up to th e APS on host. MDC 1.2 V CMOS I 1 ...

  • Finisar 10GBASE-LRM X2 - page 3

    FTLX1341E2 Product Sp ecification – October 2008 © Finisar Corporation – October 2008 Rev B Page 3 Receive Functions Reserved Reserved O O 38 39 Reserved For Future Use Reserved For Future Use RX LANE 0+ RX LANE 0– O O 41 42 Module XAUI Out put Lane 0+ Module XAUI Out put Lane 0– RX LANE 1+ RX LANE 1– O O 44 45 Module XAUI Out put Lane 1 ...

  • Finisar 10GBASE-LRM X2 - page 4

    FTLX1341E2 Product Sp ecification – October 2008 © Finisar Corporation – October 2008 Rev B Page 4 Electrical Pad Layout Figure 1- X2 Transpond er Electrical Pad Layout II. Absolute Maximum Ratings Limit Values Parameter Symbol min. max. Unit Sto rage Temp erat ure 1) T S -40 85 °C Supply Voltage +5.0 V V 5 0 6 V Supply Voltage +3.3 V V 3 0 4 ...

  • Finisar 10GBASE-LRM X2 - page 5

    FTLX1341E2 Product Sp ecification – October 2008 © Finisar Corporation – October 2008 Rev B Page 5 III. Electrical Characteristics Recommended Operating Conditions Values Parameter Symbol min. typ. max. Unit Operating Case Temperature 1) T C 0 70 °C Transponder Total Power Consum ption P 4 W Supply Voltage +5.0 V V CC5 4.75 5.0 5.25 V Supply ...

  • Finisar 10GBASE-LRM X2 - page 6

    FTLX1341E2 Product Sp ecification – October 2008 © Finisar Corporation – October 2008 Rev B Page 6 Electrical AC Characteristics ( V CC5 = 4.75 V to 5.25 V, V CC3 = 3.14 V t o 3.47 V , V CC aps = 1.152 V to 1.248 V, T C = 0°C to 70°C) Values Parameter Symbol min. typ. max. Unit XAUI Input AC Cha racteristics (TX LANE[0..3]) Baud Rate Etherne ...

  • Finisar 10GBASE-LRM X2 - page 7

    FTLX1341E2 Product Sp ecification – October 2008 © Finisar Corporation – October 2008 Rev B Page 7 Optical Specifications Parameter Symbol Min Typ Max Unit Ref. Transmitter Optical Modulation Amplitude (OMA) P OMA -4.5 +1.5 dBm Average Launc h Power P AVE -6.5 +0.5 dBm Peak Launch Power P MAX +3 dBm Optical Wavelengt h λ 1260 1 355 nm λ rms ...

  • Finisar 10GBASE-LRM X2 - page 8

    FTLX1341E2 Product Sp ecification – October 2008 © Finisar Corporation – October 2008 Rev B Page 8 Environmental Performance Operating case temperature: 0°C to +70°C Operating humidity: 0% -95% RH non-condensing Fibers and Connectors The transponder has SC receptacles for both Tx and Rx. The transponder is designed f or multim ode SC cables, ...

  • Finisar 10GBASE-LRM X2 - page 9

    FTLX1341E2 Product Sp ecification – October 2008 © Finisar Corporation – October 2008 Rev B Page 9 Eye Safety Finisar FTLX1341E2 transponders are Class 1 Laser Products. They are certified per the following standards: Feature Agency Standard Certificate Number Laser Eye Safety FDA/CDRH CDRH 21 CFR 1040 and Laser Notice 50 9210176-77 Laser Eye ...

  • Finisar 10GBASE-LRM X2 - page 10

    FTLX1341E2 Product Sp ecification – October 2008 © Finisar Corporation – October 2008 Rev B Page 10 Package Outline Figure 3-X2 Mechanical D i mensi ons IX. References The following references are provided for info rmational purposes only. The parameters and operational behavior outlined in this specification describe the com plete functionali ...

Manufacturer Finisar Category Network Card

Documents that we receive from a manufacturer of a Finisar 10GBASE-LRM X2 can be divided into several groups. They are, among others:
- Finisar technical drawings
- 10GBASE-LRM X2 manuals
- Finisar product data sheets
- information booklets
- or energy labels Finisar 10GBASE-LRM X2
All of them are important, but the most important information from the point of view of use of the device are in the user manual Finisar 10GBASE-LRM X2.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Finisar 10GBASE-LRM X2, service manual, brief instructions and user manuals Finisar 10GBASE-LRM X2. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Finisar 10GBASE-LRM X2.

A complete manual for the device Finisar 10GBASE-LRM X2, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Finisar 10GBASE-LRM X2 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Finisar 10GBASE-LRM X2.

A complete Finisar manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Finisar 10GBASE-LRM X2 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Finisar 10GBASE-LRM X2, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Finisar 10GBASE-LRM X2, that we can find in the current document
3. Tips how to use the basic functions of the device Finisar 10GBASE-LRM X2 - which should help us in our first steps of using Finisar 10GBASE-LRM X2
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Finisar 10GBASE-LRM X2
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Finisar 10GBASE-LRM X2 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Finisar 10GBASE-LRM X2?

Use the form below

If you did not solve your problem by using a manual Finisar 10GBASE-LRM X2, ask a question using the form below. If a user had a similar problem with Finisar 10GBASE-LRM X2 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)