    MODEL S: SUF 60 thru 120 SUF 100 thru 250 SUF 130 thru 500 SERIES 100, 101 and 104. 500 T ennessee W altz Parkway Ashland City , TN 37015 PRINTED IN THE U . S .A. 051 1 198152-003 SERVICING SHOULD ONL Y BE PERFORMED BY A QUALIFIED SERVICE AGENT Service Handbook COMMERCIAL GAS HIGH EFFICIENCY W A TER HEA TERS ...

  • State Industries SUF 130 THRU 500 - page 2

    ...

  • State Industries SUF 130 THRU 500 - page 3

    1 Servicing should only be performed by a Qualied Service Agent T ABLE OF CONTENTS INTRODUCTION ...................................................................... 2 QUALIFICA TIONS ..................................................................... 2 TOOLS REQUIRED .................................................................... 3 GENE ...

  • State Industries SUF 130 THRU 500 - page 4

    2 Servicing should only be performed by a Qualied Service Agent INTRODUCTION The service handbook is designed to aid in servicing and troubleshooting State W ater Heaters Ultra Force SUF commercial water heaters in the field. No duplication or reproduction of this book may be made without the express written authorization of the State W ater Hea ...

  • State Industries SUF 130 THRU 500 - page 5

    3 Servicing should only be performed by a Qualied Service Agent T OOLS REQUIRED • ELECTRICAL MUL TIMETER CAP ABLE OF MEASURING CONTINUITY/ OHMS, AC & DC VOL TS, AMPERES, MICROAMPERES, MILLIVOL TS, and FREQUENCY (Hz) • UEi Model DL289 or equivalent • DIGIT AL MANOMETER + 60" W . C. in .01" increments Note: A digital manomet ...

  • State Industries SUF 130 THRU 500 - page 6

    4 Servicing should only be performed by a Qualied Service Agent GENERAL INFORMA TION INST ALLA TION REQUIREMENTS FOR THE COMMONWEAL TH OF MASSACHUSETTS For all side wall terminated, horizontally vented power vent, direct vent, and power direct vent gas fueled water heaters installed in every dwelling, building or structure used in whole or in pa ...

  • State Industries SUF 130 THRU 500 - page 7

    5 Servicing should only be performed by a Qualied Service Agent INST ALLA TION QUICK TIPS – SUF 120 AND 150 GAS PRESSURE ADJUSTMENT PROCEDURE: GAS PRESSURE SUF 120 AND 150 MODELS Main line gas pressure to the water heater for natural gas should be between a maximum of 10.5" w .c. (2.59 kPa) for natural gas, 14.0" w .c. (3.45 kPa) for ...

  • State Industries SUF 130 THRU 500 - page 8

    6 Servicing should only be performed by a Qualied Service Agent Compare result to the de‑rated input required for the elevation at the installation location. Should it be necessary to adjust the gas pressure to the burner , to obtain the full input rate, the steps below should be followed: 3. Remove the pressure regulator cover screw and adjus ...

  • State Industries SUF 130 THRU 500 - page 9

    7 Servicing should only be performed by a Qualied Service Agent INST ALLA TION QUICK TIPS – SUF 199 AND 250 GAS PRESSURE ADJUSTMENT PROCEDURE: GAS PRESSURE SUF 199 AND 250 MODELS IMPORT ANT NOTE THE SUF 199 AND 250 MODELS INCORPORA TE A NEW GAS CONTROL, WHICH OPERA TES A T A MANIFOLD PRESSURE OF 0" w.c. (0 kPa) FOR BOTH NA TURAL AND PROP ...

  • State Industries SUF 130 THRU 500 - page 10

    8 Servicing should only be performed by a Qualied Service Agent INST ALLA TION QUICK TIPS – SUF 300, 400, 500 GAS PRESSURE ADJUSTMENT PROCEDURE: GAS PRESSURE SUF 300, 400, 500 A minimum dynamic gas supply pressure of 5.2" w.c. (1.29 kPa) for Natural Gas and 1 1" w.c. (2.74 kPa) for LP Gas is required before making any adjustment to t ...

  • State Industries SUF 130 THRU 500 - page 11

    9 Servicing should only be performed by a Qualied Service Agent INST ALLA TION QUICK TIPS – SUF 300, 400, 500 SEE MANUAL FOR COMPLETE INST ALLA TION INSTRUCTIONS & DET AILS ...

  • State Industries SUF 130 THRU 500 - page 12

    10 Servicing should only be performed by a Qualied Service Agent INST ALLA TION – VENTING CA TEGOR Y AND MA TERIALS UL TRA FORCE VENTING Category IV • Positive pressure in vent, above atmospheric. • These models will produce excessive condensate in vent. • V ent system must not be combined with any other appliances. • Flue gas temperat ...

  • State Industries SUF 130 THRU 500 - page 13

    11 Servicing should only be performed by a Qualied Service Agent VENTING T ABLES – SUF 120 ‑ 250 Maximum equivalent feet of intake and vent pipe using 3" PVC is 50 feet (15.2 m). Equivalent feet must include any 90° elbows (two 45° elbows equal one 90° elbow). Three inch diameter 90° elbows are equivalent to 5' (1.5 m) of pipe. ...

  • State Industries SUF 130 THRU 500 - page 14

    12 Servicing should only be performed by a Qualied Service Agent CONCENTRIC VENTING Concentric venting allows for a single wall penetration. For multiple water heater installation using this vent practice any additional vents of this type may be located 12" on centerline to either side of the first vent or 12" on centerline vertically ...

  • State Industries SUF 130 THRU 500 - page 15

    13 Servicing should only be performed by a Qualied Service Agent VENT CONDENSA TION Failure to properly install the drain line on the condensate elbow will result in a water heater shut down and a “blocked exhaust” fault message. The average dew point of natural gas flue products is 127°F . Propane flue products is 1 19°F . With 70°F ambi ...

  • State Industries SUF 130 THRU 500 - page 16

    14 Servicing should only be performed by a Qualied Service Agent VENTING – ALL MODELS – SINGLE PIPE DIRECT VENT – USING OUTSIDE AIR TERMINA TION CLEARANCES SIDEW ALL POWER VENT V X VENT TERMINAL AIR SUPPL Y INLE TA RE A WHERE TERMINAL IS NO T PERMITTED v v A G V FIXED CLOSED FIXED CLOSED OPERABLE OPERABLE V C B B B B F B V V A J V H M X X ...

  • State Industries SUF 130 THRU 500 - page 17

    15 Servicing should only be performed by a Qualied Service Agent VENTING – ALL MODELS – TWO PIPE DIRECT VENT – USING OUTSIDE AIR TERMINA TION CLEARANCES SIDEW ALL DIRECT VENT V X VENT TERMINAL AIR SUPPL Y INLE TA RE A WHERE TERMINAL IS NO T PERMITTED v v A G V FIXED CLOSED FIXED CLOSED OPERABLE OPERABLE V C B B B B F B V V A J V H M X X V ...

  • State Industries SUF 130 THRU 500 - page 18

    16 Servicing should only be performed by a Qualied Service Agent VENT TERMINA TION – DIRECT VENT – ALL MODELS WHEN LOCA TING THE TERMINALS ON A SIDEW ALL, THE FOLLOWING SPECIFICA TIONS PERT AINING TO TERMINAL LOCA TION MUST BE FOLLOWED. 1. The intake vent terminal and the exhaust vent terminal must terminate on the same exterior wall and mus ...

  • State Industries SUF 130 THRU 500 - page 19

    17 Servicing should only be performed by a Qualied Service Agent DIRECT VENTING – ALL MODELS The air intake provided on the unit contains a mesh screen to prevent large particles from entering the unit. WHEN THE UNIT IS TO BE SET UP AS A DIRECT VENT , THE BALANCE PLA TE AND MESH SCREEN MUST BE REMOVED BEFORE GLUING PIPE TO THE CONNECT OR. THE ...

  • State Industries SUF 130 THRU 500 - page 20

    18 Servicing should only be performed by a Qualied Service Agent CONTROL OVERVIEW Interaction with the water heater controller is through an LCD display called the Universal Interface Module (UIM) . This screen is also referred to as the “desktop” or “desktop menu” . Up and down buttons and three operation buttons allow navigation throug ...

  • State Industries SUF 130 THRU 500 - page 21

    19 Servicing should only be performed by a Qualied Service Agent The table of status icons describes graphically operational details of the water heater . Below is a legend of all the status icons: Status Icon Description The temperature of the water in the tank has fallen and the water heater will now initialize a new heating cycle. The tempera ...

  • State Industries SUF 130 THRU 500 - page 22

    20 Servicing should only be performed by a Qualied Service Agent ADJUSTING T ANK TEMPERA TURE – OPERA TING SET POINT – DIFFERENTIAL The Operating Set Point of this water heater determines the regulated temperature for the water in the tank. This parameter is adjusted in the desktop T emperature menu. Items in this menu allow you to monitor d ...

  • State Industries SUF 130 THRU 500 - page 23

    21 Servicing should only be performed by a Qualied Service Agent ACTION: Press Change then use the UP and DOWN buttons to change the temperature Set Point. DISPLA Y : Note: This procedure can also be used to change the Differential . The tank Upper and Lower T emperatures are not user changeable. They are determined by the temperature probes on ...

  • State Industries SUF 130 THRU 500 - page 24

    22 Servicing should only be performed by a Qualied Service Agent CHANGING THE DISPLA Y UNITS The desktop menu has the option of selecting between degrees Fahrenheit and degrees Celsius for temperature displays. This can be found in the “Display Settings” menu. Also in this menu, you may adjust how the back-light operates and the contrast of ...

  • State Industries SUF 130 THRU 500 - page 25

    23 Servicing should only be performed by a Qualied Service Agent ACTION: Press Update to accept the change or Cancel to reject it. DISPLA Y : ...

  • State Industries SUF 130 THRU 500 - page 26

    24 Servicing should only be performed by a Qualied Service Agent F AUL T AND W ARNING CONDITIONS – ADV ANCED DIAGNOSTIC INFORMA TION This water heater control has the ability to monitor almost all aspects of the water heater ’s operation. In the event of an undesirable or unsafe condition that occurs, the water heater control will detect thi ...

  • State Industries SUF 130 THRU 500 - page 27

    25 Servicing should only be performed by a Qualied Service Agent ACCESS T O THE CURRENT F AUL T OR W ARNING When a fault or warning has been detected by the control it will automatically be displayed on the screen and the back light will blink. If you choose to leave the current fault or warning by pressing the Back key , you can always return t ...

  • State Industries SUF 130 THRU 500 - page 28

    26 Servicing should only be performed by a Qualied Service Agent F AUL T CODES All faults, warnings, and errors are given in plain English text. Some have a Code alpha/numeric value assigned. Please read the full English text and not the alpha/numeric value when calling for assistance. Following is a complete list of all faults, warnings, and er ...

  • State Industries SUF 130 THRU 500 - page 29

    27 Servicing should only be performed by a Qualied Service Agent VIEWING THE F AUL T HIST OR Y – VIEWING INFORMA TION ABOUT THE HEA TER The controller for this water heater will store a history of ten of the last Fault and W arning conditions that occurred. This is stored in the Fault History . The information about the fault or warning will i ...

  • State Industries SUF 130 THRU 500 - page 30

    28 Servicing should only be performed by a Qualied Service Agent CONTROL SEQUENCE (TYPICAL ALL MODELS) TYPICAL SEQUENCE 1. When the control is powered it should display “waiting for connection” and “UIM v2.06”*. The manufacturer and unit model will be next. The next display will include water temperature, temperature setting and heater s ...

  • State Industries SUF 130 THRU 500 - page 31

    29 Servicing should only be performed by a Qualied Service Agent CONTROL SEQUENCE FLOW CHART ...

  • State Industries SUF 130 THRU 500 - page 32

    30 Servicing should only be performed by a Qualied Service Agent CONTROLS – CENTRAL CONTROL BOARD – CCB The Central Control Board or CCB is contained in the housing shown below . Access to the board and the wiring harness plugs can be accomplished by removing two Phillips screws holding the cover . Remove these screws to release cover The CC ...

  • State Industries SUF 130 THRU 500 - page 33

    31 Servicing should only be performed by a Qualied Service Agent This is the back of the UIM. ...

  • State Industries SUF 130 THRU 500 - page 34

    32 Servicing should only be performed by a Qualied Service Agent CONTROLS – GAS V AL VE SUF 120 The gas control valve on the SUF 120 has a built-in adjustable pressure regulator . The adjustment screw is accessed by removing the cap screw market regulator in the illustration. Inlet gas pressure may be read at the inlet pressure tap only if the ...

  • State Industries SUF 130 THRU 500 - page 35

    33 Servicing should only be performed by a Qualied Service Agent CONTROLS – GAS V AL VE SUF 199 AND 250 ADJUSTMENT PROCEDURE: GAS PRESSURE SUF 199 AND 250 MODELS IMPORT ANT NOTE THE SUF 199 AND 250 MODELS INCORPORA TE A NEW GAS CONTROL, WHICH OPERA TES A T A MANIFOLD PRESSURE OF 0" w.c. (0 kPa) FOR BOTH NA TURAL AND PROP ANE GAS. SEE THE ...

  • State Industries SUF 130 THRU 500 - page 36

    34 Servicing should only be performed by a Qualied Service Agent CONTROLS – GAS V AL VE SUF 199 AND 250 Pressure readings may be taken on the gas valve by connecting to the pressure ports on the valve. The manifold pressure on this valve is 0" WC (0 kPa) when the water heater is running. Refer to the gas pressure chart on page 4. Note: T ...

  • State Industries SUF 130 THRU 500 - page 37

    35 Servicing should only be performed by a Qualied Service Agent CONTROLS – GAS V AL VE, ORIFICE CHART – SUF 300/400 The gas control valve has a built-in field adjustable pressure regulator . The gas valve for the SUF Natural gas model is shown below . This is a 24V . solenoid operated gas valve. Low Gas Pressure Switch Refer to the replacem ...

  • State Industries SUF 130 THRU 500 - page 38

    36 Servicing should only be performed by a Qualied Service Agent CONTROLS – GAS V AL VE, ORIFICE CHART – SUF 500 The gas control valve has a built-in field adjustable pressure regulator . The regulator may be adjusted by removing the cap screw marked “regulator”. The adjustment screw is underneath. The gas valve for the SUF 500 Natural g ...

  • State Industries SUF 130 THRU 500 - page 39

    37 Servicing should only be performed by a Qualied Service Agent CONTROLS – PRESSURE SWITCHES – ALL MODELS All SUF models are provided with four pressure switches. These switches are essential to the safe and proper operation of the unit. The switches are wired to the central control board (CCB) individually and each is monitored individuall ...

  • State Industries SUF 130 THRU 500 - page 40

    38 Servicing should only be performed by a Qualied Service Agent CONTROLS – PRESSURE SWITCHES – SUF 120 THROUGH 250 Note: Check the website www .statewaterheaters.com for T echnical Bulletin S023-06 “Air Pressure Switches” under “Literature/Service Handbooks” ...

  • State Industries SUF 130 THRU 500 - page 41

    39 Servicing should only be performed by a Qualied Service Agent CONTROLS – PRESSURE SWITCHES – SUF 300, 400, 500 Note: Check the website www .statewaterheaters.com for T echnical Bulletin S023-06 “Air Pressure Switches” under “Literature/Service Handbooks” ...

  • State Industries SUF 130 THRU 500 - page 42

    40 Servicing should only be performed by a Qualied Service Agent CONTROLS – CONNECTIONS, IGNITER, FLAME SENSOR, SIGHT GLASS, POWERED ANODES The connections for the hot surface igniter and the flame sense rod are shown below . Also shown is the burner sight glass. These features are typical for all models. Flame Sensor Hot Surface Igniter Mount ...

  • State Industries SUF 130 THRU 500 - page 43

    41 Servicing should only be performed by a Qualied Service Agent HOT SURF ACE IGNITER / FLAME SENSOR / CONTROL TIMING HOT SURF ACE IGNITER This water heater is equipped with an electric hot surface igniter . The igniter material is silicone carbide and should not be handled with bare hands because of possible damage to the igniter . The normal o ...

  • State Industries SUF 130 THRU 500 - page 44

    42 Servicing should only be performed by a Qualied Service Agent BLOWER SPEED CONTROL SUF 199 AND 250 The input of the SUF 199 and SUF 250 is determined by blower . The input of the water heater may be determined by clocking the meter as shown on page 5 or by making sure the blower is receiving the proper signal. The blower rpm is controlled by ...

  • State Industries SUF 130 THRU 500 - page 45

    43 Servicing should only be performed by a Qualied Service Agent V ARIABLE FREQUENCY DRIVE – SUF 400 AND 500 The Ultra Force SUF 400 and 500 models have a variable frequency drive (VFD) that controls the rpm of the blower motor . The VFD receives a signal from the central control board that instructs the VFD to transmit the proper frequency to ...

  • State Industries SUF 130 THRU 500 - page 46

    44 Servicing should only be performed by a Qualied Service Agent V ARIABLE FREQUENCY DRIVE – BLOWER SPEED AND PRESSURE READINGS The instructions for the VFD are sent from the CCB to in the form of a DC current. The chart below lists the current readings, the frequency signal displayed by the VFD, and the pressure switch settings needed for the ...

  • State Industries SUF 130 THRU 500 - page 47

    45 Servicing should only be performed by a Qualied Service Agent WIRING DIAGRAM – SUF 120 ‑ 300 2 GREEN WHITE RED BLACK 1 1 2 BLACK 3 WHITE COMBUSTION BLOWER U PPER TEMPERATURE PROB E 1 RED (ECO) 4 RED (ECO) 2 BLACK 3 BLACK 1 BLACK120 VAC HOT 3 WHITE 120 VAC NEUTRAL 4 YEL 24 VAC 4 YEL 24 VAC LOWER TEMPERATURE PROBE HOT SURFACE IGNITER FLAME ...

  • State Industries SUF 130 THRU 500 - page 48

    46 Servicing should only be performed by a Qualied Service Agent WIRING DIAGRAM – SUF 400, 500 1 2 5 6 WHITE GREEN BLACK BLACK WHITE RED COMBUSTION BLOWER NOTE: COMBUSTION BLOWER MOTORS ON 400,000 & 500,000 Btu/hr MODELS ARE THREE PHASE (3Ø) MOTORS. BLACK, WHITE AND RED WIRES MUST BE WIRED AS SHOWN OR THE MOTOR WILL TURN BACKWARDS. THIS M ...

  • State Industries SUF 130 THRU 500 - page 49

    COMMERCIAL GAS HIGH EFFICIENCY W A TER HEA TERS 47 500 T ennessee Waltz Parkway Ashland City , TN 37015 www .statewaterheaters.com ...

Manufacturer State Industries Category Water Heater

Documents that we receive from a manufacturer of a State Industries SUF 130 THRU 500 can be divided into several groups. They are, among others:
- State Industries technical drawings
- SUF 130 THRU 500 manuals
- State Industries product data sheets
- information booklets
- or energy labels State Industries SUF 130 THRU 500
All of them are important, but the most important information from the point of view of use of the device are in the user manual State Industries SUF 130 THRU 500.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals State Industries SUF 130 THRU 500, service manual, brief instructions and user manuals State Industries SUF 130 THRU 500. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product State Industries SUF 130 THRU 500.

A complete manual for the device State Industries SUF 130 THRU 500, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use State Industries SUF 130 THRU 500 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of State Industries SUF 130 THRU 500.

A complete State Industries manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual State Industries SUF 130 THRU 500 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the State Industries SUF 130 THRU 500, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the State Industries SUF 130 THRU 500, that we can find in the current document
3. Tips how to use the basic functions of the device State Industries SUF 130 THRU 500 - which should help us in our first steps of using State Industries SUF 130 THRU 500
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with State Industries SUF 130 THRU 500
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of State Industries SUF 130 THRU 500 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning State Industries SUF 130 THRU 500?

Use the form below

If you did not solve your problem by using a manual State Industries SUF 130 THRU 500, ask a question using the form below. If a user had a similar problem with State Industries SUF 130 THRU 500 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)