    50-765 PELLET ST OVE MERIDIAN SHERWOOD INDUSTRIES IS AN ENVIRONMENT ALL Y RESPONSIBLE COMP ANY . THIS MANUAL IS PRINTED ON RECYCLED P APER. PLEA SE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE O WNER ’S MANU AL Freestanding and Fireplace Insert PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET-BURNING ROOM HEATER. FAILURE ...

  • Enviro C-11153 - page 2

    T able of Contents Introduction........................................................................................... ..................3 Rating Label Location.....................................................................................3 P ellet Quality ................................................................................... ...

  • Enviro C-11153 - page 3

    3 Introduction * This manual is designed for the home owner in conjunction with the technical manual. * R ATING L ABEL L OCATION : Freestanding: The r ating label is located on the inside of the hopper lid. Insert: The r ating label is located on the hopper cover . P ELLET Q UALITY : Pellet quality is important, please read the following: Your envi ...

  • Enviro C-11153 - page 4

    4 Introduction I MPORTANT S AFETY D ATA : Please read this entire Owner’s Manual before installing or operating your ENVIRO Pellet Stove. Failure to follow these instructions may result in property damage, bodily injury or even death. Contact your local building or fire official to obtain a permit and any information on installation restrictions ...

  • Enviro C-11153 - page 5

    5 Introduction ASHES: Disposed ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be on a non-combustible floor on the ground, well away from all combustible materials pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispensed, they should be retained ...

  • Enviro C-11153 - page 6

    32 1 / 2 " (826mm) 24 7 / 8 " (632mm) 24 3 / 4 " (629mm) Specific a tions D IMENSIONS - F REESTANDING : Figure 1: Meridian Freestanding Dimensions. 23 3 / 4 " (604mm) 12 7 / 8 " (326mm) 22 7 / 8 " (583mm) 23 7 / 8 " (605mm) Figure 2: Meridian Fireplace Insert Dimensions. D IMENSIONS - F IREPLACE I NSERT : 6 ...

  • Enviro C-11153 - page 7

    7 Oper a ting Instructions C ONTROL B OARD F UNCTIONS : 1. AUGER TRIM: Used to change feed rates on LOW ONL Y for poorer quality fuels. Push the Auger T rim button until the number 1 and 5 lights appear on the Heat Level Indicator . This will incr ease the feed r ate to 4 seconds ON time Auger pulse. This is done only on LOW to allow the burning of ...

  • Enviro C-11153 - page 8

    Figure 4: Thermostat Switch in MANUAL poition. Figure 5: Thermostat Switch in HIGH/LOW poition.           1 2 3 4 5 6 7 8 9     ...

  • Enviro C-11153 - page 9

    9 Figure 8: Efficient Flame. Oper a ting Instructions HEA T LEVEL and F ans wil l drop down to the LOW setting for 30 minutes. If the thermostat contacts close within the 30 min, the HEA T LEVEL will return to the previous MANUAL setting. If the thermostat contacts remain open the stove automatically begins its shutdown routine. The stove will re-l ...

  • Enviro C-11153 - page 10

    2-3 Days / Weekly Semi-annually or 2 T ons of Fuel Burn Pot and Liner Exhaust V ent Ash Pan Fresh air Intake T ube Inside Firebox Blower Mechanisms Door Glass Heat exchanger tubes Heat exchanger tubes Behind firebox liners Ash pan and Door gaskets All Hinges Door Latch Post Season Clean-up TOOLS REQUIRED TO CLEAN UNIT • T orx T -20 Screwdriver ? ...

  • Enviro C-11153 - page 11

    FRESH AIR INTAKE (season) Inspect periodically to be sure that it is not clogged with any f oreign materials. EXHAUST VENT (season) This vent should be cleaned every y ear or after two (2) tons of pellets. W e recommend contacting your dealer for professional cleaning. T o clean the vent pipe, tap lightly on the pipe to dislodge an y loose ash. Ope ...

  • Enviro C-11153 - page 12

    EXHAUST PASSAGES (season) Removal of the firebox backing for bi- annual cleaning (refer to Figure 10): • Open the door by lifting the handle, remove the burn pot and burn pot l iner . • Lubricate all screws with penetrating oil. • Remo ve the four (4) screws that hold the brick liner retainers in place. Remove side brick liners by sliding the ...

  • Enviro C-11153 - page 13

    W arr anty Sherwood Industries Ltd. is the manufacturer of the Enviro line of heating products. At Sherwood Industries, our commitment to the highest level of quality and customer service is the most important thing we do. Each Enviro stove is built on a tradition of using only the finest materials and is backed by our Exclusive Lifetime Limited W ...

  • Enviro C-11153 - page 14

    W arr anty 14 6. Some minor expansion, contraction, or mov ement of certain parts and resulting noise, is normal and not a defect and, therefore, is not covered under this Limited W arranty . 7 . Misuse includes over-firing. Over -firing this appliance can cause serious damage and will nullify the Limited Warr anty . 8. The Limited W arranty will c ...

  • Enviro C-11153 - page 15

    15 NAME OF OWNER: _________________________________________ ADDRESS: _________________________________________ _________________________________________ _________________________________________ PHONE:___________________________________ NAME OF DEALER: _________________________________________ ADDRESS: _________________________________________ ____ ...

Manufacturer Enviro Category Stove

Documents that we receive from a manufacturer of a Enviro C-11153 can be divided into several groups. They are, among others:
- Enviro technical drawings
- C-11153 manuals
- Enviro product data sheets
- information booklets
- or energy labels Enviro C-11153
All of them are important, but the most important information from the point of view of use of the device are in the user manual Enviro C-11153.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Enviro C-11153, service manual, brief instructions and user manuals Enviro C-11153. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Enviro C-11153.

Similar manuals

A complete manual for the device Enviro C-11153, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Enviro C-11153 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Enviro C-11153.

A complete Enviro manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Enviro C-11153 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Enviro C-11153, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Enviro C-11153, that we can find in the current document
3. Tips how to use the basic functions of the device Enviro C-11153 - which should help us in our first steps of using Enviro C-11153
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Enviro C-11153
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Enviro C-11153 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Enviro C-11153?

Use the form below

If you did not solve your problem by using a manual Enviro C-11153, ask a question using the form below. If a user had a similar problem with Enviro C-11153 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)