Manual New Buck Corporation DV23ZC

33 pages 0.7 mb
Download

Go to site of 33

Summary
  • New Buck Corporation DV23ZC - page 1

    OPERA TIONS MANUAL FOR THE MODEL DV23ZC DIRECT VENT ZERO CLEARANCE GAS FIREPLACE APPROVED FOR MOBILE HOME INSTALLATION W ARNING: If the following information in this manual is not followed exactly, a fire or explosion may result causing property dam age, personal injury, or loss of life. -DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAP ORS AND ...

  • New Buck Corporation DV23ZC - page 2

    ...

  • New Buck Corporation DV23ZC - page 3

    T ABLE OF CONTENTS Introduction .................................................................................................................. ........ 3 Specifications ................................................................................................................ ....... 3 Installation ......................................... ...

  • New Buck Corporation DV23ZC - page 4

    2 ...

  • New Buck Corporation DV23ZC - page 5

    INTRODUCTION This instruction manual will help you obtain a safe, efficient, dependable installation for your appliance and vent system. Please read and understand these instructions before begi nning your installation. The model DV23ZC is a sealed combustion, air circ ulating gas appliance designed for residential and mobile home applications. The ...

  • New Buck Corporation DV23ZC - page 6

    NOTE: Installation and repair should be perfor med by a qualified service person. The appliance should be inspected annually by a qualified professional se rvice person. More frequent inspections and cleanings may be required due to excessive lint from carpeting, bedding material, pet hair, etc. It is imperative that the c ontrol compartment, burne ...

  • New Buck Corporation DV23ZC - page 7

    GENERAL INFORMA TION LOCATION AND CLEARANCE Make sure your installation location provides adequate co mbustion and ventilation air. In selecting the location, the aes thetic and functi onal uses of the applianc e are primary concerns. However, vent system routing to the exterior and access to the fuel supply are also im portant. Consideration shoul ...

  • New Buck Corporation DV23ZC - page 8

    INST ALLA TION Figure 1 6 ...

  • New Buck Corporation DV23ZC - page 9

    IN TE RIO R V ER TIC AL INSTALLATION WITH A MAXI MUM 4 2' R I SE. NOTE: INTERIOR HORIZONTAL MI NI MUM I NST ALLAT I ON NOTE: Figure 2 NOTE : You may replace or cover this piece of m aterial with a more decorative non-combustible material when the unit is installed. SUPPLIED BY MANUFACTURER SUPPLIED BY MANUFACTURER * * * 7 ...

  • New Buck Corporation DV23ZC - page 10

    8 INST ALLA TION GENERAL INFORMATION Remove the shipping carton. Make sure the unit is not damaged. Lift the top louver and remove three (3) nuts at the upp er left, right, and cente r of the glass frame. Also, open louver at bottom and remove the three (3) nuts. Se t the door aside and pr otect from inadvertent damage. Retain nuts for reassembly. ...

  • New Buck Corporation DV23ZC - page 11

    INST ALLA TION EXTERIOR VENT LOCATIONS and RES TRICTIONS M V K A V B V C B O P E N A B L E FIXED CLOSED FIXED CLOSED V E V V F OPENABLE B V A J B D L B A H I V A G INSIDE CORNER DETAIL V = VENT TERMINAL A = AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTED TERMINATION BOX, LOCATION CHART A. Clearance abov e grade, veranda, porch, deck, or bal ...

  • New Buck Corporation DV23ZC - page 12

    INST ALLA TION NOTE: Direct-Vent (Balanced Flue) applia nces are sensitive to vent co nfigurations. Although this appliance may operate in some in stallations that fall outside th is vent requirement chart, we cannot ensure its performance. Figure 3 18' 12' 0' 6' MINIMUM - MAXIMUM VENT REQU IREMENTS * MINIMUM DISTANCE FROM BEND ...

  • New Buck Corporation DV23ZC - page 13

    INST ALLA TION VENT ASSEMBLY There are two basic types of installations a pproved with your m odel DV23ZC appliance. These are: Horizontal termination (See Figure 5) Vertical termination (See Figure 10) When planning your installation, refe r to Figure 3 to ensure the length of your vent falls into the limits specified in Figu re 3. Al so consult p ...

  • New Buck Corporation DV23ZC - page 14

    INST ALLA TION HORIZONTAL TERMINATION (continued) NOTE:  The horizontal run of vent must be level, or have a 1/4-inch rise for every 1 foot of run toward the termination. Never allow the ve nt to run downward. This could cause high temperatures and may present the possibility of a fire.  A 2" clearance (airspace) MUST be maintained on al ...

  • New Buck Corporation DV23ZC - page 15

    INST ALLA TION HORIZONTAL TERMINATION (continued) Note:  The four wood screws provided should be re placed with appropriate fasteners for stucco, brick, concrete, or other types of siding.  Venting termination shall not be rec essed in to a w all or sid ing. For structures with vinyl siding, a Vinyl Siding Standoff (Part 950) should be instal ...

  • New Buck Corporation DV23ZC - page 16

    INST ALLA TION VERTICAL TERMINATION 1. Set the gas appliance in th e desired location. Drop a plum b bob down from the ceiling to the position of the appliance flue exit, and ma rk the location where the vent will penetrate the ceiling. Drill a small hole at this point. Ne xt, drop a plumb bob from the roof to the hole previously drilled in the cei ...

  • New Buck Corporation DV23ZC - page 17

    INST ALLA TION VERTICAL TERMINATION (continued) 5. Slip the flashing over the Pipe Section(s) protru ding through the roof. S ecure the b ase of the Flashing to the roof with roofing nails. Ensure the roofing materials overlap the top edge of the Flashing as shown in Figure 12. Verify th at you have at least th e minim um clearance to combustibles ...

  • New Buck Corporation DV23ZC - page 18

    INST ALLA TION VERTICAL TERMINATION (continued) NOTES:  Use only 45 degree elbows. Use of 90 degree elbows is not allowed in ver tical terminations. The 45 degree elbows offer less restriction to the flow of flue ga ses and intake air.  For multi-story vertical in stallations, a Ceiling Firestop, (S im pson-Dura-Vent, Part 963) is required at ...

  • New Buck Corporation DV23ZC - page 19

    INST ALLA TION HIGH ALTITUDE This unit is approved in Canada for altitude from 0 to 2,000 ft. (0 to 600m) (Can 2.17-M90) with the main burner orifice supplied. For inst allations above 2,000 feet, follow current CAN/CGA-B149.1 and B149.2. In the USA refer to ANSI Z223.1 — latest edition, Appendix F, for resizing the orifice. At altitudes greater ...

  • New Buck Corporation DV23ZC - page 20

    INST ALLA TION GAS VALVE CONNECTION The gas control valve is locate d behind the lower grill. The control valve has a 3/8" NPT threaded inlet port. Secure all joints tightly using appropriate tools and sealing compound. Leak-check the installation with a soapy water so lution or el ectronic leak detec t or. DO NOT USE OPEN FLAME FOR LEAK TEST. ...

  • New Buck Corporation DV23ZC - page 21

    OPERA TION OPERA TING INSTRUCTIONS Before operating this appliance, proceed throug h the following checklist. 1. Read and understand these instructi ons before operating this appliance. 2. Check that there are no gas leaks. If you sm ell gas do not attempt to light this appliance. 3. Verify that log placement is correct. LIGHTING INSTRUCTIONS SIT - ...

  • New Buck Corporation DV23ZC - page 22

    LIGHTING INSTRUCTIONS 1. STOP! Read the safety information on page 19. 2. Make sure manual shutoff valve is fully open. 3. Turn off all electrical power to the appliance. Open access door. 4. Turn control knob clockwise ¬ to the “OFF” position. Figure 16 5. Wait five (5) minutes to clear out any ga s. Then sm ell for gas, including near the fl ...

  • New Buck Corporation DV23ZC - page 23

    NOTE: IF pilot goes out, repeat steps 4 through 10. Wait five (5) minutes before attempting to light pilot aga in. 9. Turn control knob counterclockwise « to “ON” position. 10. If using unit without wall therm ostat place “Auto/Off/Manual” switch into the “Manual” position. If using wall therm o stat place “Auto/Off/Manual” Switch ...

  • New Buck Corporation DV23ZC - page 24

    LOG INST ALLA TION 1. You must first unfold the left and right log support tabs. These tabs are folded down for shipping and must be unfolded before the rear l og is put into place. 2. Place the rear log #1 on the back side of the burner base, flat side toward the rear of the firebox. 3. Take the middle log #2, Grasp it by both ends with ember burn ...

  • New Buck Corporation DV23ZC - page 25

    OPERA TION PILOT AND FLAME Your appliance is equipped with a standing pilot to ensure proper burner i gnition. It is visible by looking over the top of the mi ddle log 6" from the right side. W hile igniting, the flame should impinge on the lighting port tube between the rear and mi ddle burner, which ignites the front and rear burner. When bu ...

  • New Buck Corporation DV23ZC - page 26

    OPTIONAL ROOM AIR BLOWER WIRING DIAGRAM CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTING WHEN SERVICING CONTROLS. WIRING ERRORS CA N CAUSE I MPROPER AND DANGEROUS OPERATION. VERIFY PROPE R OPERATION AFTER SERVICING. THE APPLIANCE, WHEN INSTALLED, MUST BE ELECTRI CALLY GROUNDED IN ACCORDANCE WITH LOCAL CODES, OR IN THE ABSENCE OF LOCAL CODES, WITH TH ...

  • New Buck Corporation DV23ZC - page 27

    ACCESSORIES OR OPTIONS This unit is equipped with a millivolt system which enables you to choose from many of the convenient options available. 1. Remote control with built in room therm ometer. 2. Wall Switch. 3. Wall Thermostat. O U T L T O I P I N O U T L T O I P I N VALVE PIEZO PILOT ROCKER SWITCH REMOTE CONTROL EYE Figure 21 25 ...

  • New Buck Corporation DV23ZC - page 28

    MAINTENANCE GENERAL MAINTENANCE Annual maintenance of the unit is required. We recommend that the fo llowing procedures be performed each year by your fireplace dealer. Clean all lint and dust build-up around the control valve and air shutter of the ventu ri. Inspect and clean with a vacuum cleaner around the vent uri for any spider webs or lint ac ...

  • New Buck Corporation DV23ZC - page 29

    SER VICING Repair and replacement work should onl y be done by a qualified service person. Always shut off the gas supply and make sure th at heater is cool before beginning any service operation. Always check for gas leaks after servicing. REPLACEMENT P AR TS A parts list with exploded view follows. Always include correct name, part number, and mo ...

  • New Buck Corporation DV23ZC - page 30

    REPLACEMENT P AR TS Figure 22 16 28 ...

  • New Buck Corporation DV23ZC - page 31

    ADDITIONAL REPLACEMENT P AR TS PART DESCRI PTION PART NUMBER *MOTOR PE SBR084 *RHEOSTAT PE BC204 *RHEOSTAT KNOB PE BC204A *THERMOSTAT 140 DEG. PE 400130 *THERMOSTAT WIRES PE 30JUMPER FRONT LOUVER ASSEMBLY T O P & B O T T O M P O D V 2 3 F G DOOR GLASS PG DV2341 DOOR GLASS GASKET TAD POLE (W/ADHESIVE) RP GT716B11 5 P I E C E L O G S E T P O 2 3 ...

  • New Buck Corporation DV23ZC - page 32

    W ARRANTY LIMITED FOUR YEAR WARRANTY FOR THE BUCK STOVE AND RELATED PR ODUCTS PLEASE READ THIS WARRANTY CAREFULLY This warranty covers your new heating unit, so long as it is owned by the original purchaser, including optional and standard accesso ries purch ased at the same tim e, subject to terms, limitations, and conditions herein set out.To m a ...

  • New Buck Corporation DV23ZC - page 33

    (D) All warranty repairs under this warranty must be performed by an authorized Buck Stove service representative. Repairs or attempted repairs by anyone other than an author- ized service representative are not covered under this warranty. In addition, these unauthorized repairs may result in additional malfunctions, the correction of which is not ...

Manufacturer New Buck Corporation Category Indoor Fireplace

Documents that we receive from a manufacturer of a New Buck Corporation DV23ZC can be divided into several groups. They are, among others:
- New Buck Corporation technical drawings
- DV23ZC manuals
- New Buck Corporation product data sheets
- information booklets
- or energy labels New Buck Corporation DV23ZC
All of them are important, but the most important information from the point of view of use of the device are in the user manual New Buck Corporation DV23ZC.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals New Buck Corporation DV23ZC, service manual, brief instructions and user manuals New Buck Corporation DV23ZC. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product New Buck Corporation DV23ZC.

A complete manual for the device New Buck Corporation DV23ZC, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use New Buck Corporation DV23ZC by users. Manuals are usually written by a technical writer, but in a language understandable to all users of New Buck Corporation DV23ZC.

A complete New Buck Corporation manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual New Buck Corporation DV23ZC - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the New Buck Corporation DV23ZC, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the New Buck Corporation DV23ZC, that we can find in the current document
3. Tips how to use the basic functions of the device New Buck Corporation DV23ZC - which should help us in our first steps of using New Buck Corporation DV23ZC
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with New Buck Corporation DV23ZC
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of New Buck Corporation DV23ZC in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning New Buck Corporation DV23ZC?

Use the form below

If you did not solve your problem by using a manual New Buck Corporation DV23ZC, ask a question using the form below. If a user had a similar problem with New Buck Corporation DV23ZC it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)