Manual Sub-Zero DO30-2B/G-TH DO30CE/B/TH

106 pages 5.36 mb
Download

Go to site of 106

Summary
  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 1

    W olf Design Guide ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 2

    Features and specications ar e subject to change at any time without notice. Visit wolfappliance.com/specs for the most up-to-date information. IMPORT ANT NOTE: Throughout this guide, dimensions may vary by ± 1 / 8 " (3) . Dimensions in parentheses ar e millimeters unless otherwise specied. Contents 3 Ovens and W arming Drawers 38 Cookt ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 3

    wolfappliance.com | 3 L Series Ovens Since their introduction a few short years ago, W olf L series electric ovens have taken the culinary world by storm—and not just for their stylish cobalt blue interior and 10 cooking modes. Thanks to a W olf innovation called dual convec- tion, the L series delivers faster , mor e consistent results for bakin ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 4

    4 | W olf Customer Care 800.222.7820 L Series Ovens 30" SINGLE OVEN WOLF BUIL T -IN OVENS 24" (610) BEHIND FRAME 27 1 / 2 " (699) 28 3 / 16 " (716) 29 7 / 8 " (759) 3" (76) 20 3 / 4 " (527) 26 1 / 16 " (662) CONDUIT CHANNEL 9 5 / 8 " (244) 8 7 / 8 " (225) 3" (76) OPEN O VEN DOOR 24" (610) ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 5

    wolfappliance.com | 5 WOLF BUIL T -IN OVENS SPECIFICA TIONS INTERIOR CAP ACITY CU FT (L) 30" Oven 4.5 (127) 36" Oven 4.4 (125) INTERIOR DIMENSIONS WHD 30" Oven 25" (635) 16 1 / 2 " (419) 19" (483) 36" Oven 30" (762) 13 1 / 4 " (337) 19" (483) 50" (1270) 29 7 / 8 " (759) 24" (610) BEHI ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 6

    6 | W olf Customer Care 800.222.7820 E Series Ovens Stainless models now feature a r edesigned stainless steel touch-action control panel, helping to cr eate great meals with ease, as well as adding a striking design feature to the kitchen. Smart technology gives the E series ten cooking modes, with W olf ’ s innovative dual convection in single ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 7

    wolfappliance.com | 7 WOLF BUIL T -IN OVENS RANGES / RANGETOPS OVENS / WARMING DRA WERS OUTDOOR GRILLS VENTILA TION COOKTOPS E Series Ovens SINGLE OVEN 23 3 / 4 " (603) BEHIND FRAME 27 7 / 8 " (708) 29 7 / 8 " (759) CONDUIT CHANNEL 27 1 / 8 " (689) 2 7 / 8 " (73) *1" (25) for professional and transitional models and 1 ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 8

    8 | W olf Customer Care 800.222.7820 WOLF BUIL T -IN OVENS RANGES / RANGETOPS VENTILA TION COOKTOPS OVENS / WARMING DRA WERS OUTDOOR GRILLS Planning Information The oven can be installed in a standard or ush inset application. If a cooktop is being installed above an oven, a minimum of 1 / 4 " (6) is requir ed between units. Location of the ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 9

    wolfappliance.com | 9 30" L and E Series Single Oven ST ANDARD INST ALLA TION E FRONT VIEW SIDE VIEW NOTE: Location of electrical supply within opening may require additional cabinet depth. Dashed line represents profile of unit . 27 1 / 4 " (692) OPENING HEIGHT 24" (610) OPENING DEPTH 28 1 / 2 " (724) OPENING WIDTH 4 3 / 4 &quo ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 10

    10 | W olf Customer Care 800.222.7820 WOLF BUIL T -IN OVENS E FRONT VIEW SIDE VIEW NOTE: Location of electrical supply within opening may require additional cabinet depth. Dashed line represents profile of unit . 24 1 / 16 " (611) OPENING HEIGHT 24" (610) OPENING DEPTH 34 1 / 2 " (876) OPENING WIDTH 7 3 / 4 " (197) TYPICAL T OP ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 11

    wolfappliance.com | 11 WOLF BUIL T -IN OVENS E FRONT VIEW SIDE VIEW NOTE: Location of electrical supply within opening may require additional cabinet depth. Dashed line represents profile of unit . 49 3 / 4 " (1264) OPENING HEIGHT 24" (610) OPENING DEPTH 28 1 / 2 " (724) OPENING WIDTH 17" (432) TYPICAL T OP VIEW E E 5" (127 ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 12

    12 | W olf Customer Care 800.222.7820 WOLF BUIL T -IN OVENS E FRONT VIEW SIDE VIEW *W ill be visible and should be finished to match cabinetr y. **1" (25) for professional and transitional models and 1 1 / 4 " (32) for contemporary model. NOTE: Location of electrical supply within opening may require additional cabinet depth. Dashed line ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 13

    wolfappliance.com | 13 WOLF BUIL T -IN OVENS 30" E Series Double Oven FLUSH INSET INST ALLA TION E FRONT VIEW SIDE VIEW *W ill be visible and should be finished to match cabinetr y. **1" (25) for professional and transitional models and 1 1 / 4 " (32) for contemporary model. NOTE: Location of electrical supply within opening may requ ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 14

    14 | W olf Customer Care 800.222.7820 WOLF BUIL T -IN OVENS 30" E Series Single Oven ST ANDARD INST ALLA TION WITH CONVECTION STEAM OVEN E 24" (610) OPENING DEPTH FRONT VIEW SIDE VIEW NOTE: Minimum base support for steam oven 100 lbs (45 kg) and E series oven 250 lb s (113 kg ) . Electrical supply for steam oven must be located in adjacen ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 15

    wolfappliance.com | 15 WOLF BUIL T -IN OVENS 30" E Series Single Oven FLUSH INSET INST ALLA TION WITH CONVECTION STEAM OVEN E FRONT VIEW SIDE VIEW 30 3 / 8 " (772) FLUSH INSET WIDTH *W ill be visible and should be finished to match cabinetr y. **1" (25) for professional and transitional models and 1 1 / 4 " (32) for contemporary ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 16

    16 | W olf Customer Care 800.222.7820 WOLF BUIL T -IN OVENS 30" E Series Single Oven FLUSH INSET INST ALLA TION WITH CONVECTION STEAM OVEN AND W ARMING DRA WER E E 30 3 / 8 " (772) FLUSH INSET WIDTH FRONT VIEW SIDE VIEW 10 5 / 8 " (270) FLUSH INSET HEIGHT W ARMING DRA WER *W ill be visible and should be finished to match cabinetr y. ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 17

    wolfappliance.com | 17 RANGES / RANGETOPS OVENS / WARMING DRA WERS OUTDOOR GRILLS VENTILA TION COOKTOPS WOLF BUIL T -IN OVENS 30" E Series Single Oven FLUSH INSET INST ALLA TION WITH DRA WER MICROW A VE AND WARMING DRA WER E E E 28 1 / 8 " (714) FLUSH INSET HEIGHT 15 3 / 8 " (391) FLUSH INSET HEIGHT 10 5 / 8 " (270) FLUSH INSET ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 18

    18 | W olf Customer Care 800.222.7820 WOLF BUIL T -IN OVENS 30" E Series Single Oven FLUSH INSET INST ALLA TION WITH MICROW A VE AND WARMING DRA WER E E E E 25" (635) FLUSH INSET DEPTH FINISHED CLEA TS* 1" (25) OR 1 1 / 4 " (32)** T OP VIEW *W ill be visible and should be finished to match cabinetr y. **1" (25) for professi ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 19

    wolfappliance.com | 19 WOLF BUIL T -IN OVENS RANGES / RANGETOPS OVENS / WARMING DRA WERS OUTDOOR GRILLS VENTILA TION COOKTOPS ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 20

    20 | W olf Customer Care 800.222.7820 Convection Steam Oven The legacy of the “combination oven” goes back decades, to innovative chefs in America and Europe who embraced the combination of air movement with superheated steam to achieve superior results—fr om breads and r oasts to delicate shes, seafood and vegetables. W olf combines the b ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 21

    wolfappliance.com | 21 WOLF CONVECTION STEAM OVEN RANGES / RANGETOPS OVENS / WARMING DRA WERS OUTDOOR GRILLS VENTILA TION COOKTOPS 17 7 / 8 " (454) 21 3 / 16 " (538) 23 1 / 2 " (597) 29 7 / 8 " (759) WITH TRIM 14 3 / 16 " (360) 1" (25) OPEN O VEN DOOR 2 13 / 16 " (71) 21 1 / 2 " (546) BEHIND FRAME SPECIFICA T ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 22

    22 | W olf Customer Care 800.222.7820 WOLF CONVECTION STEAM OVEN RANGES / RANGETOPS VENTILA TION COOKTOPS OVENS / WARMING DRA WERS OUTDOOR GRILLS Planning Information The convection steam oven can be installed with or without side trim in a standard or ush inset application. A minimum base support of 100 lbs (45 kg) is requir ed. The electrical ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 23

    wolfappliance.com | 23 WOLF CONVECTION STEAM OVEN RANGES / RANGETOPS OVENS / WARMING DRA WERS OUTDOOR GRILLS VENTILA TION COOKTOPS FRONT VIEW SIDE VIEW NOTE: Con v ection steam ov en with or without trim requires the same opening dimensions . Electrical supply must be located in adjacent cabinet within 3' (.9 m) of opening. Dashed line represe ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 24

    24 | W olf Customer Care 800.222.7820 WOLF CONVECTION STEAM OVEN RANGES / RANGETOPS VENTILA TION COOKTOPS OVENS / WARMING DRA WERS OUTDOOR GRILLS Convection Steam Oven FLUSH INSET INST ALLA TION W FLUSH INSET WIDTH FRONT VIEW SIDE VIEW FINISHED CLEA TS* 23" (584) FLUSH INSET DEPTH 1" (25) *W ill be visible and should be finished to match ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 25

    wolfappliance.com | 25 Microwave Ovens As true cooking instruments, W olf microwave ovens have features that make fast meals better meals. Drawer micr o- wave ovens can be conveniently located undercounter , in a corner or below an oven. They can be installed in a standard or ush inset application. W olf also offers both a roomy , powerful stand ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 26

    26 | W olf Customer Care 800.222.7820 WOLF MICROWA VE OVENS RANGES / RANGETOPS VENTILA TION COOKTOPS OVENS / WARMING DRA WERS OUTDOOR GRILLS 21 7 / 8 " (556) BEHIND FRAME 15 1 / 8 " (384) 23 5 / 8 " (600) 21 5 / 8 " (549) POWER CORD CHANNEL 1 1 / 4 " (32) 4 5 / 8 " (118) 1 3 / 4 " (45) 14 5 / 8 " (372) 16 1 / ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 27

    wolfappliance.com | 27 WOLF MICROWA VE OVENS RANGES / RANGETOPS OVENS / WARMING DRA WERS OUTDOOR GRILLS VENTILA TION COOKTOPS E SERIES TRIM 13 3 / 8 " (340) FREE- ST ANDING 24" (610) FREEST ANDING 18 1 / 4 " (464) WITH TRIM 18" (457) BEHIND TRIM *1 1 / 4 " (32) for contemporary E series trim only . 1" (25) OR 1 1 / 4 & ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 28

    28 | W olf Customer Care 800.222.7820 Planning Information DRAWER MICROW A VE W olf drawer microwave ovens can be installed in a standard or ush inset application. The cabinet must be able to sup- port 125 lbs (57 kg) . Finish the edges of the opening. They may be visible when the drawer is open. For ush inset installations, a minimum 1 / 8 & ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 29

    wolfappliance.com | 29 WOLF MICROWA VE OVENS RANGES / RANGETOPS OVENS / WARMING DRA WERS OUTDOOR GRILLS VENTILA TION COOKTOPS Drawer Microwave Oven ST ANDARD INST ALLA TION E FRONT VIEW SIDE VIEW 22" (559) OPENING DEPTH NOTE: All dr aw er micr owave ove ns require the same opening dimensions . Dashed line represents profile of unit . 14 3 / 4 ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 30

    30 | W olf Customer Care 800.222.7820 WOLF MICROWA VE OVENS RANGES / RANGETOPS VENTILA TION COOKTOPS OVENS / WARMING DRA WERS OUTDOOR GRILLS Drawer Microwave Oven FLUSH INSET INST ALLA TION E W FLUSH INSET WIDTH FRONT VIEW SIDE VIEW FINISHED CLEA TS* 23 1 / 4 " (591) FLUSH INSET DEPTH 1 1 / 4 " (32) *W ill be visible and should be finishe ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 31

    wolfappliance.com | 31 WOLF MICROWA VE OVENS RANGES / RANGETOPS OVENS / WARMING DRA WERS OUTDOOR GRILLS VENTILA TION COOKTOPS E FRONT VIEW SIDE VIEW 20 1 / 8 " (511) OPENING DEPTH NOTE: Dashed line represents profile of unit. T OP VIEW 18 7 / 8 " (479) OPENING HEIGHT W OPENING WIDTH BASE SUPPO RT Convection Microwave Oven INST ALLA TION W ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 32

    32 | W olf Customer Care 800.222.7820 WOLF MICROWA VE OVENS RANGES / RANGETOPS VENTILA TION COOKTOPS OVENS / WARMING DRA WERS OUTDOOR GRILLS Standard Micr owave Oven INST ALLA TION WITH TRIM E FRONT VIEW SIDE VIEW 20" (508) OPENING DEPTH NOTE: Dashed line represents profile of unit. W OPENING WIDTH T OP VIEW 17" (432) OPENING HEIGHT BASE ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 33

    wolfappliance.com | 33 W arming Drawers W olf warming drawers are designed to take care of pr e- pared foods until it’ s time to serve them. Y ou can adjust the temperature, keeping moist foods moist and crisp foods crisp. W arming drawers are ideal for pr oong dough. Drawer fronts ar e available to match the look of W olf ovens, sealed burner ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 34

    34 | W olf Customer Care 800.222.7820 22 3 / 4 " (578) 28 1 / 4 " (718) 9" (229) 10 3 / 8 " (264) 3 / 4 " (19) 3 / 4 " ( 19) A B W WIDTH 21 1 / 2 " (546) OPEN DRA WER DIMENSIONS WOLF WARMING DRA WERS W arming Drawers DRAWER FRONT OPTIONS W olf warming drawer fronts allow for many design options, but the warming dr ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 35

    wolfappliance.com | 35 WOLF WARMING DRA WERS RANGES / RANGETOPS OVENS / WARMING DRA WERS OUTDOOR GRILLS VENTILA TION COOKTOPS Planning Information The warming drawer must be installed with a W olf drawer front, avail able thr ough an authorized W olf dealer . For local dealer information, visit the nd a showroom section of our website, wolfappli ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 36

    36 | W olf Customer Care 800.222.7820 WOLF WARMING DRA WERS W arming Drawer ST ANDARD INST ALLA TION E FRONT VIEW SIDE VIEW 23" (584) OPENING DEPTH NOTE: Location of electrical supply within opening may require additional cabinet depth. Dashed line represents profile of unit . 9 1 / 8 " (232) OPENING HEIGHT 28 5 / 8 " (727) OPENING W ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 37

    wolfappliance.com | 37 W arming Drawer FLUSH INSET INST ALLA TION 30 3 / 8 " (772) FLUSH INSET WIDTH FRONT VIEW SIDE VIEW *W ill be visible and should be finished to match cabinetr y. **1" (25) for professional and transitional models and 1 1 / 4 " (32) for contemporary model. Custom front panel depth is dependent on panel thickness. ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 38

    ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 39

    wolfappliance.com | 39 Induction Cooktops Ultrafast. Exceptionally ener gy efcient. Induction cooking has been popular among European chefs and homeowners for decades. Now W olf leads the way in bringing this remarkable technology to North American kitchens. Its secret is magnetism. Electr omagnetic elements cause iron and magnetic stainless coo ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 40

    40 | W olf Customer Care 800.222.7820 WOLF INDUCTION COOKTOPS Induction Cooktops 15" TRANSITIONAL 2 1 / 2 " (64) 1 1 / 4 " (32) 7 / 8 " (22) ALL SIDES 21" (533) 15" (381) CONDUIT 2 1 / 2 " (64) 30" (762) 1 1 / 4 " (32) 7 / 8 " (2 2) ALL SIDES 21" (533) CONDUIT 36" (914) 2 1 / 2 " (64) ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 41

    wolfappliance.com | 41 WOLF ELECTRIC COOKTOPS Electric Cooktops Behind that sophisticated, minimalist exterior (available either with stainless steel trim or in our trimless design) there lurks a high-performance cooking instrument fairly beg- ging to be put through its paces. All the elements featur e a true simmer setting that hold sauces and ste ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 42

    42 | W olf Customer Care 800.222.7820 WOLF ELECTRIC COOKTOPS Electric Cooktops 15" TRANSITIONAL HEA TING ZONES 15" ELECTRIC COOKTOP WA TTS 10" (254) T riple 900 / 1800 / 2500 6 1 / 2 " (165) Single 1200 30" ELECTRIC COOKTOP WA TTS 10" (254) T riple 900 / 1800 / 2500 10" (254) T riple (CT30E-208/S) 900 / 1800 / 230 ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 43

    wolfappliance.com | 43 WOLF INDUCTION AND ELECTRIC COOKTOPS Planning Information A minimum height clearance of 6 1 / 4 " (159) is required fr om the top of the countertop to any combustible surface directly below the cooktop. Contemporary induction and electric cooktops can be mounted ush with the top of the countertop, or as a frame- less ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 44

    44 | W olf Customer Care 800.222.7820 15" Cooktop ST ANDARD INST ALLA TION WOLF INDUCTION AND ELECTRIC COOKTOPS 13 1 / 2 " (343) 19 1 / 2 " (495) 2 1 / 2 " (64) min 2 1 / 2 " (64) min FRONT VIEW SIDE VIEW COUNTERT OP CUT -OUT NO TE : S haded ar ea ab ove co untertop indica tes minimum cl ea ra nc e to combus tibl e surf ace ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 45

    wolfappliance.com | 45 COUNTERT OP CUT -OUT 10" (254) 4 1 / 2 " (114) E 3 1 / 2 " (89) FRONT VIEW SIDE VIEW NO TE : S haded ar ea ab ove co untertop indica tes minimum cl ea ra nc e to combus tibl e surf aces , combus tibl e mate ri al s cannot be locate d wi thin t his ar ea . El ec tr ical supp ly location on ly applies to installa ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 46

    46 | W olf Customer Care 800.222.7820 30" and 36" Cooktops FLUSH INST ALLA TION WOLF INDUCTION AND ELECTRIC COOKTOPS A RECESS 21 1 / 8 " (537) RECESS 1 9 / 16 " (40) min W CUT -OUT WIDTH COUNTERT OP CUT -OUT 19 1 / 2 " (495) 2 1 / 2 " (64) min 2 1 / 2 " (64) min 10" (254) 4 1 / 2 " (114) E 3 1 / 2 " ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 47

    wolfappliance.com | 47 WOLF GAS COOKTOPS RANGES / RANGETOPS OVENS / WARMING DRA WERS OUTDOOR GRILLS VENTILA TION COOKTOPS Gas Cooktops Like their built-in oven counterparts, the new generation of W olf gas cooktops features three new looks—transi- tional, professional, and contemporary . New performance enhancements make delicious results even mo ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 48

    48 | W olf Customer Care 800.222.7820 WOLF GAS COOKTOPS RANGES / RANGETOPS VENTILA TION COOKTOPS OVENS / WARMING DRA WERS OUTDOOR GRILLS Gas Cooktops 30" TRANSITIONAL 36" TRANSITIONAL 30" (762) 7 / 8 " (22) ALL SIDES 21" (533) 4" (102) 36" (914) 7 / 8 " (22) ALL SIDES 4" (102) 21" (533) 30" PRO ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 49

    wolfappliance.com | 49 WOLF GAS COOKTOPS RANGES / RANGETOPS OVENS / WARMING DRA WERS OUTDOOR GRILLS VENTILA TION COOKTOPS Planning Information A minimum height clearance of 5 1 / 2 " (140) is required fr om the top of the countertop to any combustible surface directly below the cooktop. If a cooktop is installed above an oven, a minimum of 1 / ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 50

    50 | W olf Customer Care 800.222.7820 WOLF GAS COOKTOPS RANGES / RANGETOPS VENTILA TION COOKTOPS OVENS / WARMING DRA WERS OUTDOOR GRILLS Gas Cooktop ST ANDARD INST ALLA TION 10" (254) 4" (102) 3 1 / 2 " (89) FRONT VIEW SIDE VIEW COUNTERT OP CUT -OUT NO TE : S haded ar ea ab ove co untertop indica tes minimum cl ea ra nc e to combus t ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 51

    wolfappliance.com | 51 RANGES / RANGETOPS OVENS / WARMING DRA WERS OUTDOOR GRILLS VENTILA TION COOKTOPS WOLF INTEGRA TED MODULES Integrated Modules Passion for cooking reaches new dimensions with our 15" integrated modules. Seven models cover the gamut of cooking, from searing to deep frying to induction. Combine modules à la carte–style to ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 52

    52 | W olf Customer Care 800.222.7820 7 / 8 " (22) ALL SIDES 4" (102) 21" (533) 15" (381) 21" (533) 15" (381) 6 1 / 4 " ( 159) 1 / 2 " ( 13) SIDES 1" (25) FRONT / BA CK 1 / 2 " (13) SIDES 1" (25) FRONT / BA CK 7 1 / 2 " ( 191) 6" (152) DRAIN OUTLET 21" (533) 15" (381) 7 1 / ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 53

    wolfappliance.com | 53 RANGES / RANGETOPS OVENS / WARMING DRA WERS OUTDOOR GRILLS VENTILA TION COOKTOPS Planning Information When multiple cooktops or modules are installed side by side, the countertop cut-out dimension is determined by adding the width of each product plus 1 / 4 " (6) for each ller strip, then subtracting 1" (25) . Re ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 54

    54 | W olf Customer Care 800.222.7820 Planning Information Refer to the illustrations on the following pages for instal- lation of integrated modules. For induction and electric modules, refer to the pr evious cooktop sections. ELECTRICAL When multiple cooktops or modules are installed side by side, each must have its own separate electrical supply ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 55

    wolfappliance.com | 55 Planning Information GAS SUPPL Y A gas supply line of 3 / 4 " (19) rigid pipe must be provided to the gas module. If local codes permit, a certied, 3' (.9 m) long, 1 / 2 " (13) or 3 / 4 " (19) ID exible metal appliance connector is recommended to connect the units 1 / 2 " NPT female inlet to the ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 56

    56 | W olf Customer Care 800.222.7820 Grill Module ST ANDARD INST ALLA TION WOLF INTEGRA TED MODULES 13 1 / 2 " (343) 19 1 / 2 " (495) 2 1 / 2 " (64) min 2 1 / 2 " (64) min FRONT VIEW SIDE VIEW COUNTERT OP CUT -OUT NO TE : S haded ar ea ab ove co untertop indica tes minimum cl ea ra nc e to combus tibl e surf aces , combus tibl ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 57

    wolfappliance.com | 57 Steamer Module ST ANDARD INST ALLA TION WOLF INTEGRA TED MODULES NO TE : S haded ar ea ab ove co untertop indica tes minimum cl ea ra nc e to combus tibl e surf aces , combus tibl e mate ri al s cannot be locate d wi thin t his ar ea . FRONT VIEW SIDE VIEW COUNTERT OP CUT -OUT 13" (330) 18" (457) 7" (178) E 30& ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 58

    58 | W olf Customer Care 800.222.7820 FRONT VIEW SIDE VIEW COUNTERT OP CUT -OUT NO TE : S haded ar ea ab ove co untertop indica tes minimum cl ea ra nc e to combus tibl e surf aces , combus tibl e mate ri al s cannot be locate d wi thin t his ar ea . 13" (330) 18" (457) 7" (178) E 30" (762) 7 5 / 8 " (194) 6" (152) 12 ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 59

    wolfappliance.com | 59 Gas and Multi-Function Cooktops ST ANDARD INST ALLA TION WOLF INTEGRA TED MODULES RANGES / RANGETOPS OVENS / WARMING DRA WERS OUTDOOR GRILLS VENTILA TION COOKTOPS FRONT VIEW SIDE VIEW COUNTERT OP CUT -OUT NO TE : S haded ar ea ab ove co untertop indica tes minimum cl ea ra nc e to combus tibl e surf aces , combus tibl e mate ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 60

    ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 61

    wolfappliance.com | 61 Dual Fuel Ranges Discover a new world of cooking—the best of two worlds, actually—with a W olf dual fuel range. T opside, gas cooking in all its glory , with the ne control of dual-stacked, sealed burners and options that include the remarkable French top. Below , that marvel of culinary technology , the W olf convec- ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 62

    62 | W olf Customer Care 800.222.7820 Dual Fuel Ranges 30" RANGE 36" RANGE WOLF DUAL FUEL RANGES 48" RANGE 60 1 / 8 " (1527) 9 1 / 4 " (235) 36 7 / 8 " (937)* 45 7 / 8 " (1165) 55 7 / 8 " (1419) 40 7 / 8 " (1038) 47" (1194) 26 1 / 8 " (664) 25" (635) 24 1 / 8 " (613) 27 1 / 2 " ( ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 63

    wolfappliance.com | 63 Planning Information When installing against a combustible surface, a minimum 10" (254) riser is requir ed for a 36" dual fuel range with charbroiler or griddle and all 48" and 60" models. Follow all minimum clearances to combustible surfaces shown in the illustration on the following page. It is recommend ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 64

    64 | W olf Customer Care 800.222.7820 WOLF DUAL FUEL RANGES RANGES / RANGETOPS VENTILA TION COOKTOPS OVENS / WARMING DRA WERS OUTDOOR GRILLS Dual Fuel Range INST ALLA TION FRONT VIEW SIDE VIEW *W ithout ventilation hood, 36 " (914) minimum clearance countertop to combustible materials, 44 " (118) for charbroiler . NO TE : S haded ar ea ab ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 65

    wolfappliance.com | 65 Gas Ranges Our gas ranges offer the same function, durability and exhilarating performance our ranges have become famous for . Now add the ne contr ol of dual-stacked, sealed burners for gas cooking with superior results. Choose from a multitude of sizes and features to t your cooking style. Standard featur es include a ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 66

    66 | W olf Customer Care 800.222.7820 60 1 / 8 " (1527) 43 3 / 8 " (1102) 25 3 / 8 " (645) 27 " (686) 9 1 / 4 " (235) 28 3 / 8 " (721) *37" (940) MIN TO 38" (965) MAX. 2 1 / 2 " (64) 37" (940)* 36" (914) 37" (940)* 46" (1 168) 56" (1 422) 41" ( 104 1) WOLF GAS RANGES Gas Ran ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 67

    wolfappliance.com | 67 WOLF GAS RANGES RANGES / RANGETOPS OVENS / WARMING DRA WERS OUTDOOR GRILLS VENTILA TION COOKTOPS Planning Information When installing against a combustible surface, a minimum 20" (508) riser is requir ed. Follow all minimum clearances to combustible surfaces shown in the illustration on the fol- lowing page. BURNER RA TI ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 68

    68 | W olf Customer Care 800.222.7820 WOLF GAS RANGES Gas Range INST ALLA TION 12" (305) GAS 5" (127) 2" (51) 7 3 / 4 " (1 97) 5 3 / 4 " (146) 12" (305) 10" (254) FRONT VIEW SIDE VIEW *W ithout ventilation hood, 42 " (1067) minimum clearance countertop to combustible materials, charbroiler and GR488 require n ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 69

    wolfappliance.com | 69 WOLF SEALED BURNER RANGETOPS Sealed Burner Rangetops W olf sealed bur ner rangetops incorporate all the gas cooking features of a W olf dual fuel range. Customize your rangetop with your preferr ed combination of burners (from four to six), infrared griddle or charbr oiler , or the r emarkable French top. Compar ed with conve ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 70

    70 | W olf Customer Care 800.222.7820 47 7 / 8 " (1216) 9 1 / 4 " (235) 17 1 / 2 " (445) 27 1 / 2 " (699) 12 1 / 2 " (318) 26 1 / 8 " (664) 28 1 / 2 " (724) 8 1 / 2 " (216) 7 1 / 2 " (191) 24 1 / 8 " (613) 8 1 / 2 " (216) Sealed Burner Rangetops 30" RANGETOP 48" RANGETOP BURNER RA TIN ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 71

    wolfappliance.com | 71 Planning Information The platform must be able to support 200 lbs (91 kg) for a 30" rangetop, 250 lbs (113 kg) for a 36" rangetop and 300 lbs (136 kg) for a 48" rangetop. The platform must include a cut-out for gas supply and electrical connections. When installing against a combustible surface, a minimum 5&quo ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 72

    72 | W olf Customer Care 800.222.7820 FRONT VIEW SIDE VIEW *W ithout ventilation hood, 36 " (914) minimum clearance countertop to combustible materials, 44 " (118) for charbroiler . NO TE : S haded ar ea ab ove co untertop indica tes minimum cl ea ra nc e to combus tibl e surf aces , combus tibl e mate ri al s cannot be locate d wi thin t ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 73

    ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 74

    74 | W olf Customer Care 800.222.7820 Outdoor Grills and Modules T aste what happens when a heritage of professional cooking moves from the kitchen to the patio. Like their indoor coun- terparts, W olf outdoor grills are precision instruments. Con- structed of heavy-duty stainless steel, the 30", 36", 42" and 54" grills have pow ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 75

    wolfappliance.com | 75 10 3 / 4 " (273) 30" (762) 27 3 / 4 " (705) 13" (330) W WIDTH MAX DOO R/ DRA WER CLEARANCE 22" (559) 24" (610) TO GRILL PLA TFORM 36 1 / 2 " (927) 27 3 / 4 " (705) 12" (305) 3" ( 76 ) 30" (762) HOOD CLOSED 12 1 / 2 " (318) TO GRILLING SURF AC E 27" (686) W WIDTH ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 76

    76 | W olf Customer Care 800.222.7820 WOLF OUTDOOR GRILLS Planning Information For portable applications, W olf grill carts are designed specically to t grill models OG30, OG36 and OG42 and the side burner . Model OG54 is designed for built-in appli- cations only . W olf outdoor grills and the bur ner module are designed for easy placement in ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 77

    wolfappliance.com | 77 20" (508) 3 / 4 " (19) 18 7 / 8 " (479) 30" (762) 28 5 / 8 " (727) 20 3 / 4 " (527) 11 5 / 16 " (287) 25 7 / 8 " (657) 3 / 4 " (19) 9 1 / 2 " (241) 30" (762) 27" (686) 20 3 / 4 " (527) 19" (483) A B 3 / 4 " (19) 1 1 / 4 " (32) WOLF OUTDOOR GRILLS ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 78

    78 | W olf Customer Care 800.222.7820 11 3 / 4 " (298) OPENING HEIGHT DOORS / DRA WERS OPENING WIDTH 24 1 / 4 " (616) OPENING DEPTH OPENING HEIGHT 6" (152) 1" (25) min GRILL OPENING 13 / 16 " (2 1) COUNTER TO P O VERHANG GRILL O VERLAP FRONT VIEW T OP VIEW W OPENING WIDTH NO TE : S haded ar ea abo ve co untertop indica tes ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 79

    wolfappliance.com | 79 WOLF OUTDOOR GRILLS 10" (254) OPENING HEIGHT 24 1 / 4 " (616) OPENING DEPTH 6" (152) MODULE OPENING 9 / 16 " (14) COUNTER TO P O VERHANG MODULE O VERLAP FRONT VIEW T OP VIEW 12" (305) OPENING NO TE : S haded ar ea abo ve co untertop indica tes minimum cl ea ra nc e to combus tibl e surf aces , combus ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 80

    ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 81

    wolfappliance.com | 81 Cooktop V entilation Hoods Behind the sculpted lines of W olf cooktop ventilation hoods, there’ s a lot of har d-nosed functional thinking. Brilliant halogen lighting illuminates your cooking surface. Powerful multi-speed blowers whisk away smoke and odors. Five-layer mesh lters can be removed easily for cleaning. W all- ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 82

    82 | W olf Customer Care 800.222.7820 6 7 / 8 " (175) 30 1 / 2 " (775) TO 48 1 / 2 " (1232) 19 1 / 8 " (486) 30" (762) 4 1 / 2 " (114) min 18" (457) 12" (305) 21" (533) 1 9 / 16 " (40) 6" (152) 18" (457) 12" (305) 19 1 / 8 " (486) 32 11 / 16 " (830) TO 50 7 / 8 " (1292) ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 83

    wolfappliance.com | 83 WOLF COOKTOP VENTILA TION Planning Information W olf cooktop ventilation hoods are recommended for use with W olf induction, electric and gas cooktops and inte- grated modules. These hoods have a telescopic chimney ue that accommodates ceiling heights from 8' (2.4 m) to 9' (2.7 m) . A ue extension to accommoda ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 84

    84 | W olf Customer Care 800.222.7820 Cooktop Low-Prole Hoods Behind the contemporary lines of the cooktop low-prole hoods, there’ s a lot of har d-nosed functional thinking. Bril- liant halogen lighting illuminates your cooking surface. Pow- erful multi-speed blowers whisk away smoke and odors. W all-mount and island hoods are constructed ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 85

    wolfappliance.com | 85 20 1 / 8 " (511) 3 1 / 8 " (79) 5 7 / 8 " (149) TO 18 3 / 8 " (467) 10 7 / 8 " (276) 9 7 / 8 " (251) 29 1 / 8 " (740) TO 41 1 / 2 " (1054) W WIDTH 17 3 / 4 " (451) 31" (788) TO 48 3 / 4 " (1238) 20 1 / 8 " (511) 3 1 / 8 " (79) 7 7 / 8 " (200) TO 25 1 / 2 &q ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 86

    86 | W olf Customer Care 800.222.7820 WOLF COOKTOP VENTILA TION Planning Information W olf cooktop low-prole hoods are r ecommended for use with W olf induction, electric and gas cooktops and inte- grated modules. These hoods have a telescopic chimney ue that accommodates ceiling heights from 8' (2.4 m) to 9' (2.7 m) with a nishe ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 87

    wolfappliance.com | 87 RANGES / RANGETOPS OVENS / WARMING DRA WERS OUTDOOR GRILLS VENTILA TION COOKTOPS WOLF COOKTOP VENTILA TION Downdraft V entilation Constructed of heavy duty stainless steel, the W olf down- draft rises from the countertop to whisk away odor and smoke into stainless steel, mesh lters and can be low- ered beneath the countert ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 88

    88 | W olf Customer Care 800.222.7820 WOLF COOKTOP VENTILA TION RANGES / RANGETOPS VENTILA TION COOKTOPS OVENS / WARMING DRA WERS OUTDOOR GRILLS 2" (51) 14" (356) 28 3 / 4 " (730) W DOWNDRAFT WIDTH A CHIMNEY WIDTH 6 3 / 4 " (172) 10" (254) 13" (330) 13" (330) 15" (381) 2 1 / 2 " (64) 2 3 / 8 " (60) ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 89

    wolfappliance.com | 89 WOLF COOKTOP VENTILA TION RANGES / RANGETOPS OVENS / WARMING DRA WERS OUTDOOR GRILLS VENTILA TION COOKTOPS Planning Information W olf downdrafts can be installed with most W olf cooktops, but are not compatible with contemporary induction and electric cooktops and the grill, steamer and fryer modules. Downdrafts can be instal ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 90

    90 | W olf Customer Care 800.222.7820 E FRONT VIEW SIDE VIEW *6 " (152) back from countertop cut-out when internal blower is rear mounted . NOTE: Inter nal bl ower 6" (152 ) ro und, side , re ar or bottom disc ha rg e. In-lin e an d re mote bl ower 10 " (254) ro und, re ar disc ha rg e. Cente rl in e indica tes cent er of downdr aft ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 91

    wolfappliance.com | 91 FRONT VIEW SIDE VIEW 19" (483) PLA TFORM DEPTH FRONT VIEW SIDE VIEW *6 " (152) back from countertop cut-out when internal blower is rear mounted . NOTE: Inter nal bl ower 6" (152 ) ro und, side , re ar or bottom disc ha rg e. In-lin e an d re mote bl ower 10 " (254) ro und, re ar disc ha rg e. Cente rl in ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 92

    ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 93

    wolfappliance.com | 93 WOLF PRO VENTILA TION Pro V entilation Hoods Professional heritage shines thr ough in W olf professional- style ventilation. Exteriors are heavy-duty , welded stainless steel, so nely hand-nished that they appear seamless. Pro wall and island hoods are available in a variety of widths. Stainless steel bafe lters a ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 94

    94 | W olf Customer Care 800.222.7820 Pro Hoods LOW-PROFILE W ALL HOOD 27" DEEP WALL HOOD 24" DEEP WALL HOOD 10" (254) 4" (102) 22" (559) 12" (305) W WIDTH 27" (686) 12" (305) 4" (102) 18" (457) W WIDTH WOLF PRO VENTILA TION RANGES / RANGETOPS VENTILA TION COOKTOPS OVENS / WARMING DRA WERS OUTDOOR G ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 95

    wolfappliance.com | 95 4" (102) 24" (610) 13 1 / 2 " (343) WIDTH MINUS 18" (457) 18" (457) W WIDTH 18" (457) 4" (102) 34" (864) 13" (330) WIDTH MINUS 18" (457) W WIDTH WIDTH MINUS 6" (152) 12" (305) 4" (102) 19 1 / 4 " (489) 22 1 / 2 " (572) 12" (305) 3" (76) 3&quo ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 96

    96 | W olf Customer Care 800.222.7820 WOLF PRO VENTILA TION Planning Information Pro ventilation hoods and liners ar e recommended for use with all W olf cooking appliances. Wall hoods should be at least as wide as the cooking surface, and island hoods should be lar ger by 3" (76) on each side. For optimal performance in wall hood applications ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 97

    wolfappliance.com | 97 WOLF PRO VENTILA TION Installation LOW-PROFILE, 24" AND 27" DEEP W ALL HOODS RANGES / RANGETOPS OVENS / WARMING DRA WERS OUTDOOR GRILLS VENTILA TION COOKTOPS E 6" (152) 5" (127) 30" (762) TO 36" (914) BO TTOM EDGE TO COUNTER TO P WALL CHIMNEY HOOD E 6" (152) 5" (127) 30" (762) TO 3 ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 98

    98 | W olf Customer Care 800.222.7820 Blower Assemblies For W olf ventilation hoods and downdrafts that do not include a blower assembly , an internal, in-line or remote blower assembly must be selected to accommodate the cooking appliance, CFM requir ements and homeowner pref- erences. Internal, in-line and remote blowers ar e avail able through a ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 99

    wolfappliance.com | 99 WOLF VENTILA TION RECOMMENDA TIONS W olf Product CFM CFM MODEL COOKTOP HOOD DOWNDRAFT PRO HOOD COOKTOP / MODULE CT15I CT15E CT15G IG15* IS15* IF15* IM15 215 150 215 CT30I CT30IU* CT30E CT30EU* CG304 450 350 500 CT36I CT36IU* CT36E CT36EU* CG365 600 500 500 DUAL FUEL RANGE DF304 500 DF366 DF364C DF364G 900 DF486C DF486G DF484C ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 100

    100 | W olf Customer Care 800.222.7820 WOLF VENTILA TION RECOMMENDA TIONS W olf V entilation Blower Options BLOWER INTERNAL CFM 300* 450* 500 600 900 1200 COOKTOP HOOD CTWH30 • • • CTWH36 IH4227 • • • • COOKTOP LOW-PROFILE HOOD CTEWH36 CTEWH45 DOWNDRAFT DD30 DD36 DD45 • PRO LOW-PROFILE W ALL HOOD PW302210 PW362210 • PW422210 PW482 ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 101

    wolfappliance.com | 101 WOLF VENTILA TION RECOMMENDA TIONS W olf V entilation Blower Options BLOWER IN-LINE REMOTE CFM 600 1100 600 900 1200 1500 COOKTOP HOOD CTWH30 • • • • • • CTWH36 IH4227 • • • • • • COOKTOP LOW-PROFILE HOOD CTEWH36 CTEWH45 • • DOWNDRAFT DD30 DD36 DD45 • • • PRO LOW-PROFILE W ALL HOOD PW302210 ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 102

    102 | W olf Customer Care 800.222.7820 W olf Product Shipping W eight SHIPPING WEIGHT BUIL T -IN OVEN LB (KG) 30" L / E Series Single Oven 273 (124) 30" L / E Series Double Oven 466 (211) 36" L Series Single Oven 288 (131) MICROWA VE OVEN LB (KG) 24" Drawer Microwave 91 (41) 30" Drawer Microwave 96 (44) Convection Microwave ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 103

    wolfappliance.com | 103 W olf Product Shipping W eight SHIPPING WEIGHT DUAL FUEL RANGE LB (KG) 30" Range 325 (147) 36" Range 445–470 (202–213) 48" Range 665–750 (302–340) 60" Range 875–950 (397–431) GAS RANGE LB (KG) 30" Range 325 (147) 36" Range 445–470 (202–213) 48" Range 650–750 (295–340) 60 ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 104

    Wolf Appliance Residential Limited Warranty FOR RESIDENTIAL USE FULL TWO YEAR WARRANTY* For two years from the date of original installation, this Wolf Appliance product warranty covers all parts and labor to repair or replace, under normal residential use, any part of the product that proves to be defective in materials or workmanship. All service ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 105

    Wolf Appliance Outdoor Limited Warranty* FOR RESIDENTIAL USE FULL ONE YEAR WARRANTY** For one year from the date of original installation, this Wolf Appliance product warranty covers all parts and labor to repair or replace, under normal residential use, any part of the product that proves to be defective in materials or workmanship. All service pr ...

  • Sub-Zero DO30-2B/G-TH DO30CE/B/TH - page 106

    WOLF APPLIANCE, INC. P.O. BOX 44848 MADISON, WI 53744 WOLFAPPLIANCE.COM 800.222.7820 WDG 2/ 201 4 ...

Manufacturer Sub-Zero Category Oven

Documents that we receive from a manufacturer of a Sub-Zero DO30-2B/G-TH DO30CE/B/TH can be divided into several groups. They are, among others:
- Sub-Zero technical drawings
- DO30-2B/G-TH DO30CE/B/TH manuals
- Sub-Zero product data sheets
- information booklets
- or energy labels Sub-Zero DO30-2B/G-TH DO30CE/B/TH
All of them are important, but the most important information from the point of view of use of the device are in the user manual Sub-Zero DO30-2B/G-TH DO30CE/B/TH.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Sub-Zero DO30-2B/G-TH DO30CE/B/TH, service manual, brief instructions and user manuals Sub-Zero DO30-2B/G-TH DO30CE/B/TH. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Sub-Zero DO30-2B/G-TH DO30CE/B/TH.

A complete manual for the device Sub-Zero DO30-2B/G-TH DO30CE/B/TH, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Sub-Zero DO30-2B/G-TH DO30CE/B/TH by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Sub-Zero DO30-2B/G-TH DO30CE/B/TH.

A complete Sub-Zero manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Sub-Zero DO30-2B/G-TH DO30CE/B/TH - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Sub-Zero DO30-2B/G-TH DO30CE/B/TH, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Sub-Zero DO30-2B/G-TH DO30CE/B/TH, that we can find in the current document
3. Tips how to use the basic functions of the device Sub-Zero DO30-2B/G-TH DO30CE/B/TH - which should help us in our first steps of using Sub-Zero DO30-2B/G-TH DO30CE/B/TH
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Sub-Zero DO30-2B/G-TH DO30CE/B/TH
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Sub-Zero DO30-2B/G-TH DO30CE/B/TH in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Sub-Zero DO30-2B/G-TH DO30CE/B/TH?

Use the form below

If you did not solve your problem by using a manual Sub-Zero DO30-2B/G-TH DO30CE/B/TH, ask a question using the form below. If a user had a similar problem with Sub-Zero DO30-2B/G-TH DO30CE/B/TH it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)