    METROLOGIC INSTRUMENTS, INC. MS1690 Focus ® Series Area Imaging Bar Code Scanner Installation and User's Guide ...

  • Honeywell MS1690 Focus - page 2

    Copyright © 2008 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any for m or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Cop yright Act of 1976. Trademarks Metrologic is a registered trademark ...

  • Honeywell MS1690 Focus - page 3

    ii T ABLE OF C ONTENTS Introduction Product Overview ............................................................................................. 1 Scanner and Accessori es ................................................................................. 2 Scanner Comp onents ........................................................................ ...

  • Honeywell MS1690 Focus - page 4

    iii T ABLE OF C ONTENTS Configurati on Modes .......................................................................................... 32 Upgrading the Flash ROM Firmware .................................................................. 33 Scanner and Cable T erminations Scanner Pinout Connecti ons ................................................ ...

  • Honeywell MS1690 Focus - page 5

    1 I NTRODUCTION Product Overvie w Metrologic's MS1690 Focus ® series of high performance hand-h eld area imaging bar code scanners utilizes high-resoluti on CMOS imaging sensors for superior image quality. Omnipl anar, Inc.’s SwiftDecoder ® software, for provides reliable decoding of both 1D and 2D bar code s ymbologies. Sharp images can b ...

  • Honeywell MS1690 Focus - page 6

    2 I NTRODUCTION Scanner and Accessories B ASI C K IT Part # Description MS1690 Area Imaging Bar Code Scanner 00-02544 MetroSelect ® Single-Line Conf iguration Guide* 00-02281 Supplemental Configuration G uide* 00-02098 MS1690 Series Area Imaging Bar Code Scanner Installation and User’s Guide* * Available on the Metrologic website - www.metrologi ...

  • Honeywell MS1690 Focus - page 7

    3 I NTRODUCTION Scanner and Accessories O PTIONAL A CCESSORIES Part # Description 53-53213x-N-3 USB Full Speed Cable, Locking Plus-Po wer™ Type A, 2.7 m (9 ft.) coiled cord, lo ng strain relief, black 53-53214x-N-3 USB Full Speed Cable, Locking Plus-Po wer™ Type A, 4.5 m (15 ft.) coiled cord, lo ng strain relief, black This cable is for use wit ...

  • Honeywell MS1690 Focus - page 8

    4 I NTRODUCTION Scanner Components Figure 1. Scanner Components Item Description 1 Yellow LED See Visual Indicators (on page 17) 2 White LED See Visual Indicators (on page 17) 3 Blue LED See Visual Indicators (on pag e 17) 4 Speaker See Audible Indica tors (on page 16) 5 Trigger 6 Red Window LED Aperture 7 Cable Release See The PowerLink Cabl e (on ...

  • Honeywell MS1690 Focus - page 9

    5 I NTRODUCTION The PowerLink Cable Connecting Important: If the PowerLink cable is not fully ‘latched’ the unit can power intermittently. Figure 2. Figure 3. Disconnecting Before removing the cable from the scanner, Metrologic recommends that the power on the host system is off and the power supply has been disco nnected from the PowerLink cab ...

  • Honeywell MS1690 Focus - page 10

    6 I NTRODUCTION Labels Each scanner has a label loc ated on the underside of the hea d. This label provides the unit’s model number, date of manufacture, serial number, CE and caution information. The follo wing figur e gives an example of the lab el and its location. Figure 5. Label Sample and Location Caution: To maintain compliance with applic ...

  • Honeywell MS1690 Focus - page 11

    7 I NSTALLING THE S CANNER TO THE H OST S YSTEM RS232 MS1690-14 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the MS1690. There will be an audible click when the connector lock engages. 3. Connect the 9-pin D-type connector of the communication cable to the proper COM port of the host ...

  • Honeywell MS1690 Focus - page 12

    8 I NSTALLING THE S CANNER TO THE H OST S YSTEM Keyboard Wedge MS1690-47 1. Turn off the host device. 2. Plug the 10-pin RJ45 male end of the PowerLink cable into 10-pi n socket on the MS1690. There will be an audible click when the connector lock engag es. 3. Disconnect the keyboard from the host device. 4. Connect the “Y” ends of the communic ...

  • Honeywell MS1690 Focus - page 13

    9 I NSTALLING THE S CANNER TO THE H OST S YSTEM Stand Alone Keyboard MS1690-47 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the MS1690. There will be an audible click when the connector lock engages. 3. Plug the other end of the communication cable into the host’s keyboard po rt. 4 ...

  • Honeywell MS1690 Focus - page 14

    10 I NSTALLING THE S CANNER TO THE H OST S YSTEM IBM MS1690-11 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the MVC cable into the 10-pin socket on the MS1690. There will be an audible click when the connector lock engages 3. Connect the other end of the MVC cable to the host device. 4. Turn on the host device. 5. The MS1690 wil ...

  • Honeywell MS1690 Focus - page 15

    11 I NSTALLING THE S CANNER TO THE H OST S YSTEM Integrated USB: Full Speed MS1690-40 Low Speed MS1690-38 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the USB cable into the 10-pin socket on the MS1690. There will be an audible click when the connector lock engag es. 3. Plug the USB type A end of the USB cable into the host’s ...

  • Honeywell MS1690 Focus - page 16

    12 S TAND K ITS Stand Components, MLPN 46-00147 Figure 11. Stand Components Item Description Qty. a. Stand Base Qty. 1 b. Flexible Shaft Qty. 1 c. F lexible Shaft Cover Qty. 1 d. Scanner Cradle Qty. 1 e. ¼" – 20 x 3/8" Flat Head Philli ps, 100° Undercut Qty. 2 f. #8 Round Head Wood Screw Qty. 2 ...

  • Honeywell MS1690 Focus - page 17

    13 S TAND K ITS Hard Mounting the Stand (Optional) Metrologic provides two #8 wood scre ws for securing the stand base to the counter top. The following figure provides th e pilot hole dimensions for sec uring the stand base. Figure 12. Stand Base Hole Pattern (Not to Scale) ...

  • Honeywell MS1690 Focus - page 18

    14 S TAND K ITS Assembling the Stand Figure 13. Assembling the Stand ...

  • Honeywell MS1690 Focus - page 19

    15 S CANNER O PERATION Two Default Modes of Op eration* Multi-Trigger, Out of Stand 1. The IR detects an object in the IR activation range and automatically turns on linear illumination. 2. Aim the scanner’s line of light over the bar code. 3. Pull the trigger to initiate scanning. The scanner’s light output will start to flash as it attempts t ...

  • Honeywell MS1690 Focus - page 20

    16 S CANNER O PERATION Audible Indicators When the MS1690 is in operation, the scan ner provides audible fee dback. These sounds indicate the status of the scanner. Eight settings are availa ble for the tone of the beep (normal, 6 alternate ton es and no tone). To change the tone, refer to the MetroSelect Si ngle-Line Configur ation Guide, MLPN 00- ...

  • Honeywell MS1690 Focus - page 21

    17 S CANNER O PERATION Visual Indicators The MS1690 has three LED indic ators (yellow, white and blue) located on the top of the scanner. When the scanner is on, the flashing or stationary activity of the LEDs indicates the status of the current scan and the scanner. No LEDs are Illuminated The LEDs will not be illuminat ed if the scanner is not re ...

  • Honeywell MS1690 Focus - page 22

    18 S CANNER O PERATION Failure Modes Long Razzberry Tone – During Power Up Failed to initialize or configure the sc anner. If the scanner does not respond after reprogramming, return the scanner for repair. Short Razzberry Tone – During Scanning An Invalid bar code has been scanne d when in configuratio n mode. ...

  • Honeywell MS1690 Focus - page 23

    19 S CANNER O PERATION Depth of Field by Minimum Bar Code Element Width M INIMUM B AR C ODE E LEMENT W IDTH 1D PDF A B C D E F G mm .132 .19 .254 .33 .533 .254 .381 mils 5.2 7.5 10.4 13 21 10 15.9 Figure 16. Depth of Field by Minimum Bar Code E lement Width Specifications are subjec t to change without notice. ...

  • Honeywell MS1690 Focus - page 24

    20 S CANNER O PERATION IR Activation Range The MS1690 has a built in obj ect detection sensor that instantly turns on the scanner when an object is presented with in the scanner’s IR activatio n Area. Figure 17. IR Activation Area Specifications are subjec t to change without notice . ...

  • Honeywell MS1690 Focus - page 25

    21 T ROUBLESHOOTING G UIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-Me tro or 1- 800-436-3876 to pres erve the limited warranty terms. All Interfaces MS1690 Series Troubleshooting Gui de Symptoms Possible Causes Solution No power is being supplied to the scanner. Check transformer, outlet a ...

  • Honeywell MS1690 Focus - page 26

    22 T ROUBLESHOOTING G UIDE Symptoms Possible Causes Solution The unit powers up, but does not beep when bar code is scanned. The beeper is disabled and no tone is selected. Enable the beeper and select a tone. The unit powers up, but does not scan and/or beep. The bar code symbology tryi ng to be scanned is not enabled. UPC/EAN, Code 39, interleave ...

  • Honeywell MS1690 Focus - page 27

    23 T ROUBLESHOOTING G UIDE Symptoms Possible Causes Solution The print quality of the bar code is suspect. Check print mode. The type of printer could be the problem. Change print settings (i.e. change to econo mode or high speed) . The aspect ratio of the bar code is out of tolerance. Check print mode. The type of printer could be the problem. Cha ...

  • Honeywell MS1690 Focus - page 28

    24 T ROUBLESHOOTING G UIDE Symptoms Possible Causes Solution The unit is transmitting each character twi ce. The configuration is not set correctly. Increase interscan code delay setting. Adjust whether the F0 break is transmitted. It may be necessary to try this in both settings. Alpha characters show as lower case. The computer is in Caps Lock mo ...

  • Honeywell MS1690 Focus - page 29

    25 D ESIGN S PECIFICATIONS MS1690 D ESIGN S PECIFICATIONS O PERATIONAL Light Source: LED 645 nm Pulse Duration: 1 ms to 8 ms Maximum Output of an Osram LED: Maximum 85 mA emits 3,120 mlm Depth of Scan Field: 0 mm – 254 mm (0" – 10") for 0.330 mm (13 mil) Bar Code at Default Setting 49 mm W x 19 mm H (1.9” W x 0. 8” H) at 20 mm (0. ...

  • Honeywell MS1690 Focus - page 30

    26 D ESIGN S PECIFICATIONS MS1690 D ESIGN S PECIFICATIONS E LECTRICAL Input Voltage: 5.0VDC ± 0.25V Peak = 2 W (Typical) Operating = 1.65 W (Typical) Power: Idle / Standby = 800 mW (Typical) Peak = 400 mA (Typical) Operation = 330 mA (Typical) Current: Idle / Standby = 160 mA (Typical) DC Transformer: Class 2; 5.2VDC @ 1 A For Regulatory Complianc ...

  • Honeywell MS1690 Focus - page 31

    27 A PPLICATIONS AND P ROTOCOLS The model number on each scann er includes the scanner number a nd factory default communications proto col. S CANNER V ERSION I DENTIFIER C OMMUNICATION P ROTOCOL ( S ) 11 IBM 468X/469X, RS232-TXD, RXD, RT S, CTS 14 RS232 (TX, RX, RTS, CTS, DTR) 38 Low Speed USB 40 Full-speed USB MS1690 - 47 Keyboard Wedge, Stand-Al ...

  • Honeywell MS1690 Focus - page 32

    28 D EFAULT S ETTINGS – C OMMUNICATION P ARAMETER S Many functions of the scanner can be “config ured” – that is, enabled or disabled. The scanner is shipped from the factor y c onfigured to a set of default conditions. The default parameter of the scanner has an asterisk (*) in the charts on the following pages. If an asterisk is not in th ...

  • Honeywell MS1690 Focus - page 33

    29 D EFAULT S ETTINGS – C OMMUNICATION P ARAMETER S PARAMETER DEFAULT RS232 IBM 46XX KBW USB Maxicode 9 9 9 9 Aztec 9 9 9 9 Postals 9 9 9 9 Mod 43 Check on Code 39 9 9 9 9 MSI-Plessy 10/10 Check Digit 9 9 9 9 MSI- Pless y Mod 10 Ch eck D igit * 9 9 9 9 Paraf Support ITF 9 9 9 9 ITF Symbol Lengths Variable 9 9 9 9 Symbol Length Lock None 9 9 9 9 B ...

  • Honeywell MS1690 Focus - page 34

    30 D EFAULT S ETTINGS – C OMMUNICATION P ARAMETER S PARAMETER DEFAULT RS232 IBM 46XX KBW USB Transmit lead zero on UPC-E 9 9 9 9 Transmit UPC-A number system * 9 9 9 9 Transmit UPC-A Manufacturer ID# * 9 9 9 9 Transmit UPC-A Item ID# * 9 9 9 9 Transmit Codabar Start/Stop C haracters 9 9 9 9 CLSI Editing (Enabl e) 9 9 9 9 Transmit Mod 43 Check dig ...

  • Honeywell MS1690 Focus - page 35

    31 D EFAULT S ETTINGS – C OMMUNICATION P ARAMETER S PARAMETER DEFAULT RS232 IBM 46XX KB W USB XON/XOFF Handshaking 9 ACK/NAK 9 Two Digit Supplements 9 9 9 9 Five Digit Supplements 9 9 9 9 Bookland 9 9 9 9 977 (2 digit) Supplemental Requirement 9 9 9 9 Supplements are not Required * 9 9 9 9 Two Digit Redundancy * 9 9 9 9 Five digit Redundancy 9 9 ...

  • Honeywell MS1690 Focus - page 36

    32 C ONFIGURATION M ODES The MS1690 Series has three modes of confi guration. • Bar Codes The MS1690 can be configur ed by scanning the bar codes include d in the Metrologic Single-Line Co nfiguration Guide ( MLPN 00-02544). This manual can be downloaded for FREE from Metrologic’s website (www.metrologic.com). • MetroSet 2 This user-friendly ...

  • Honeywell MS1690 Focus - page 37

    33 U PGRADING THE F LASH ROM F IRMWARE The MS1690 Focus is part of Metrologic's line of scann ers with flash upgradeable firmware. The upgrade process requir es a new firmware file supplied to the customer by a customer service representative  and Metrologic's MetroSet 2 software  . A personal computer running Windo ws 95 or grea ...

  • Honeywell MS1690 Focus - page 38

    34 S CANNER AND C ABLE T ERMINATIONS Scanner Pinout Connections MS1690-14, RS232 Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 RTS Output 5 CTS Input 6 DTR Input 7 Reserved 8 Reserved 9 +5VDC The MS1690 scanner interfaces terminate to a 10-pin, RJ45 Female Socket. The serial # label indic ates the interface enabled when the ...

  • Honeywell MS1690 Focus - page 39

    35 S CANNER AND C ABLE T ERMINATIONS Scanner Pinout Connections MS1690-38, Low Speed USB Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 RTS Output 5 CTS Input 6 USB D+ 7 V USB 8 USB D- 9 +5VDC 10 Shield Ground MS1690-40, Full Speed USB Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 RTS Output 5 CTS Inpu ...

  • Honeywell MS1690 Focus - page 40

    36 S CANNER AND C ABLE T ERMINATIONS Cable Connector Configurations (Host End) “Standard” PowerLink Cable 53-53000-3 Coiled Pin Function 1 Shield Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 DTR Input/Light Pen Source 5 Power/Signal Ground 6 Reserved 7 CTS Input 8 RTS Output 9 +5VDC Stand Alone Keyboard Po werLink Cable 53-53020-3 Pin ...

  • Honeywell MS1690 Focus - page 41

    37 S CANNER AND C ABLE T ERMINATIONS Cable Connector Configurations (Host End) Keyboard Wedge Po werLink Cable 53-53002-3 Coiled Pin Function 1 Keyboard Clock 2 Keyboard Data 3 No Connect 4 Power Ground 5 +5 VDC Pin Function 1 PC Data 2 No Connect 3 Power Ground 4 +5 VDC 5 PC Clock 6 No Connect Metrologic will supply an adap ter cable with a 5-pin ...

  • Honeywell MS1690 Focus - page 42

    38 L IMITED W ARRANTY The MS1690 Focus ® series scanners are manu factured by Metrol ogic at its Blackw ood, New Jersey , U.S.A. facility and at its Suzhou , China facility. The MS16 90 series scanners have a fiv e (5) year limited warranty from the date of manufacture . Metrologic w arrants and represents th at all MS1690 series scanners are free ...

  • Honeywell MS1690 Focus - page 43

    39 R EGULATORY C OMPLIANCE Safety ITE Equipment IEC 60950-1, EN 60950-1 LED Class 1 LED Product: IEC 60825-1:1993+A1+A2, EN 60825-1:1994+A1+A2 Caution Use of controls or adj ustments or performan ce of procedures other than tho se specified herei n may result in h azardous radi ation exposur e. Under no circum stances sh ould the cust omer attempt ...

  • Honeywell MS1690 Focus - page 44

    40 R EGULATORY C OMPLIANCE EMC Emissions FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity CISPR 24, EN 55024 Changes or modifications not expressly approved by the party respo nsible for compliance could void the user’s authority to operate the equipment. Class A Devices The follo wing is applicabl e when the scann er cable is g reater in lengt ...

  • Honeywell MS1690 Focus - page 45

    41 R EGULATORY C OMPLIANCE EMC Changes or modifications not expressly approved by the party respo nsible for compliance could void the user’s authority to operate the equipment. Class B Devices The following is applicable w hen the scanner cable is les s than 3 meters (9.8 feet) in length w hen full y extended: Les instructions ci-de ssous s’ap ...

  • Honeywell MS1690 Focus - page 46

    42 P ATENTS This METROLOGIC product may be covered by, but not limited to, one or mo re of the following U.S. Patents: U.S. Patent No.: 7,086,595; 7,128,266; 7,213,76 2; 7,216,810; 7,225,988; 7,225, 989; No license right or sublicense is granted, either expressly or by implication, estoppel, or otherwise, under any METROLOGIC or third party intelle ...

  • Honeywell MS1690 Focus - page 47

    43 I NDEX A AC ................................. 2, 8–13, 29 Accessori es ................................... 2 Adapter .................................... 2, 42 Apertu re......................................... 5 Audible Indica tor .............. 19–20, 37 B Bar Code ................... 23– 26, 27, 36 Bar Code Element ..................... ...

  • Honeywell MS1690 Focus - page 48

    44 I NDEX M Maintenanc e .................................. 7 MetroSelect ..................... 18, 30, 36 MetroSet 2 .................................... 37 Mode of Oper ation ....................... 17 N Notice s ........................................ 44 P Patent .......................................... 49 PDF ................................ ...

  • Honeywell MS1690 Focus - page 49

    45 ...

  • Honeywell MS1690 Focus - page 50

    ...

  • Honeywell MS1690 Focus - page 51

    ...

  • Honeywell MS1690 Focus - page 52

    January 2008 Printed in USA 00 - 02098F ...

Manufacturer Honeywell Category Barcode readers

Documents that we receive from a manufacturer of a Honeywell MS1690 Focus can be divided into several groups. They are, among others:
- Honeywell technical drawings
- MS1690 Focus manuals
- Honeywell product data sheets
- information booklets
- or energy labels Honeywell MS1690 Focus
All of them are important, but the most important information from the point of view of use of the device are in the user manual Honeywell MS1690 Focus.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Honeywell MS1690 Focus, service manual, brief instructions and user manuals Honeywell MS1690 Focus. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Honeywell MS1690 Focus.

A complete manual for the device Honeywell MS1690 Focus, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Honeywell MS1690 Focus by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Honeywell MS1690 Focus.

A complete Honeywell manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Honeywell MS1690 Focus - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Honeywell MS1690 Focus, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Honeywell MS1690 Focus, that we can find in the current document
3. Tips how to use the basic functions of the device Honeywell MS1690 Focus - which should help us in our first steps of using Honeywell MS1690 Focus
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Honeywell MS1690 Focus
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Honeywell MS1690 Focus in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Honeywell MS1690 Focus?

Use the form below

If you did not solve your problem by using a manual Honeywell MS1690 Focus, ask a question using the form below. If a user had a similar problem with Honeywell MS1690 Focus it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)