    Honeywell H1008 Automatic Humidity Contr ol with HumidiCalc+  Softwar e Copyright © 1998 Honeywell Inc. • All Rights Reserved Rev 1.0 May 27, 1998 ...

  • Honeywell H1008 - page 2

    Rev 2. 0 63-7048 1998 Hone yw ell Inc. Page 2 of 22  Automatic Humidity Control The Honey well H1008 Automatic Humidity Control with HumidiCalc+  Software is the world’s most advance d stand-alone humidity control. Simple to install, easy to troubleshoot, it is designed to save the installing contractor time, while maximizing benefits to th ...

  • Honeywell H1008 - page 3

    Rev 2. 0 63-7048 1998 Hone yw ell Inc. Page 3 of 22  Defining a Comfortable Humidity Level Much research has been conducted on what combination of temperature and humidity creates the most comfortable indoor environment. The 1997 ASHRAE Fundamentals Handbook 1 defines how comfort is perceived as a function of temperature and humidity . Figure 2 ...

  • Honeywell H1008 - page 4

    Rev 2. 0 63-7048 1998 Hone yw ell Inc. Page 4 of 22 The messag e to take away from all this is: If you are in the business of trying to provide a comfortable indoor environment, controlling a humidifier by sensing re lative humidity may not result in optimum control. Especially poor performance may result when the temperature in the living space ex ...

  • Honeywell H1008 - page 5

    Rev 2. 0 63-7048 1998 Hone yw ell Inc. Page 5 of 22 Figure 3 illustrates why condensation occurs: Figure 3 – Tem p erature Profile of Double Pane Window Figure 3 shows the temperature profile through a ty pical double pane window. I f it is 70  F inside and 0  F outside, depending on the insulating value of the window, the temperature at th ...

  • Honeywell H1008 - page 6

    Rev 2. 0 63-7048 1998 Hone yw ell Inc. Page 6 of 22  Outdoor T emperature Compensating Hu midity Controls Honey well, with the Perfec t Climate Comfort Center  , was the first to introduce an electronic humidity control sy stem for the reside ntial market designe d to automatically adjust humidity levels based on outdoor temperature. This sys ...

  • Honeywell H1008 - page 7

    Rev 2. 0 63-7048 1998 Hone yw ell Inc. Page 7 of 22 The AutoTrac  control does not have the ability to provide true de wpoint control. This may result in overhumidification a t times when the temperature is g reater than norma l conditions and underhumidification if the temperature is less than normal conditions. For example, i f during night se ...

  • Honeywell H1008 - page 8

    Rev 2. 0 63-7048 1998 Hone yw ell Inc. Page 8 of 22  H1008 Automatic Hum idity Control w ith HumidiCalc+  - The T echnical Approach We found that there is more than a casual relationship between furnace run time and outdoor temperature. I n fact, in a single stage heating sy stem, in steady state, the percentag e of burner on-time (% on) is l ...

  • Honeywell H1008 - page 9

    Rev 2. 0 63-7048 1998 Hone yw ell Inc. Page 9 of 22 oversize). In this case the furnace will only be running 50% of the time at the ASHRAE design temperature of –16  F. Next, we looked at the insulation values of windows, and found that naturally, there is a relationship between the temperature of the inside surface of the window and the outdo ...

  • Honeywell H1008 - page 10

    Rev 2. 0 63-7048 1998 Hone yw ell Inc. Page 10 of 22 adjusting a single input value, we can achieve a control point that satisfied every one of the thousands of combinations of the variables. Voila  . By adjusting a single knob setting we can provide a solution for the entire range of five input variables. Figure 7 shows the operational characte ...

  • Honeywell H1008 - page 11

    Rev 2. 0 63-7048 1998 Hone yw ell Inc. Page 11 of 22 Nobody has more knowledge about heating loads than Honey well, the world leader in temperature control. More furnaces are controlled by Honey well thermostat s than any other, so nobody understands the science of temperature control better than we do. I n order for the prediction of outdoor tempe ...

  • Honeywell H1008 - page 12

    Rev 2. 0 63-7048 1998 Hone yw ell Inc. Page 12 of 22 -20 -10 0 10 20 30 40 50 60 70 80 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 0 5 10 15 20 25 30 35 40 Furnace Cy cles Humidifier C ycles Outdoor Temp. Dewpoint W indow Te m p. Temp. Setpoint Room Tem p. Time (hrs ) Tem p er atu r e ( o F) Dig itia l O u tp ut Figure 8 – Software Simulation o ...

  • Honeywell H1008 - page 13

    Rev 2. 0 63-7048 1998 Hone yw ell Inc. Page 13 of 22 -20 -10 0 10 20 30 40 50 60 70 80 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 0 5 10 15 20 25 30 35 40 Furna c e Cycles Humidifier C ycles Outdoor Tem p. Dewpoin t W indow Temp . Temp. Setpoint Indoor Tem p. Time (hrs ) Tem p er atu r e ( o F) Dig itia l O u tp ut Figure 9 – H1008 Autom atic ...

  • Honeywell H1008 - page 14

    Rev 2. 0 63-7048 1998 Hone yw ell Inc. Page 14 of 22 -20 -10 0 10 20 30 40 50 60 70 80 00:0 0:00 01:0 0:00 02:0 0:00 03:0 0:00 04:0 0:00 05:0 0:00 06:0 0:00 07 :00:00.0 08:0 0:00 09:0 0:00 10:0 0:00 11:0 0:00 12:0 0:00 13:0 0:00 14 :00:00.0 15:0 0:00 16:0 0:00 17 :00:00.0 18:0 0:00 19:0 0:00 20:0 0:00 21:0 0:00 22:0 0:00 23:0 0:00 24:0 0:00 0 5 10 ...

  • Honeywell H1008 - page 15

    Rev 2. 0 63-7048 1998 Hone yw ell Inc. Page 15 of 22  Making th e Best of a Duct Mou nted Hu midity Control One of the things we learned early on in this development was that a return air duct is not the best place to mount a humidistat that controls only by relative humidity . There are two major factors th at can dramaticall y affect t he accu ...

  • Honeywell H1008 - page 16

    Rev 2. 0 63-7048 1998 Hone yw ell Inc. Page 16 of 22 -20 -10 0 10 20 30 40 50 60 70 80 90 100 08: 00:00 08:30:00 .0 09: 00:00 09: 30:00 10: 00:00 10: 30:00 11: 00:00 11: 30:00 12: 00:00 12:30:00 .0 13: 00:00 13: 30:00 14:00:00 .0 0 5 10 15 20 25 30 35 40 Dewpoin t Fur nace Cycles (W ) Humidifie r Cycles Fan Cy cles (G) Duct RH Room Temp. Duct Temp. ...

  • Honeywell H1008 - page 17

    Rev 2. 0 63-7048 1998 Hone yw ell Inc. Page 17 of 22 2. Humidity Control Located Too Close to By pass Duct A second problem that can occur in many installations is a result of the humidity control being located too close to the by pass duct. We alway s recommend mounting the humidity control as far upstream from the by pass duct as possible (> 2 ...

  • Honeywell H1008 - page 18

    Rev 2. 0 63-7048 1998 Hone yw ell Inc. Page 18 of 22 dewpoint increases slightly in response to the humidifier cy cles. During this period the relativ e humidity sensed in the duct is as low as 13 %. Because t he H1008 controls based on dewpoint, it is able to cy cle intermittently during the temperature re covery pe riod when the relative humidity ...

  • Honeywell H1008 - page 19

    Rev 2. 0 63-7048 1998 Hone yw ell Inc. Page 19 of 22 While the humidifier was on during the entire recovery period starting at 4:15 a.m., the sensed RH ranged from 20 to 30 %. The continuous operation of the humidifier caused the dewpoint in the house to exceed the window temperature for over two hours. Contrast this performance with the performanc ...

  • Honeywell H1008 - page 20

    Rev 2. 0 63-7048 1998 Hone yw ell Inc. Page 20 of 22 a ¾” diamete r hole to be cut in the duct. Drilling this hole with a uni-bit is a snap. Simply drill the hole, place the control on the duct, and secure it with self- tapping screws. Figure 14 – H1008 Sensors This method of mounting gr eatly improves the sealing of the return air duct. Build ...

  • Honeywell H1008 - page 21

    Rev 2. 0 63-7048 1998 Hone yw ell Inc. Page 21 of 22 Log ic to determine if the fan is running is determined from the equipment inputs so a current sensing relay is never required, providing additional savings to the contractor on jobs that would normally require one. 4. Automatic Configuration and Diagnostics Unlike AutoTrac  , the H1008 does n ...

  • Honeywell H1008 - page 22

    Rev 2. 0 63-7048 1998 Hone yw ell Inc. Page 22 of 22  Direct Comparison Chart – Honeywell H1008 Automatic Humidity Control w ith HumidiCalc+  Software vs. AutoTrac  Honeywell H1008 AutoTrac Installat ion Outdoor Sens or Not required for si ngle stage f urnaces. Recom mended f or heat pum ps and multi-stage f urnaces. Required for all ins ...

  • Honeywell H1008 - page 23

    ...

  • Honeywell H1008 - page 24

    2 XXXXXXXXXX XX-XXXX Honeywell Europe S.A. 3 Avenue du Bourget 1140 Brussels Belgium Honeywell Asia Pacific Inc. Room 3213-3225 Sun Hung Kai Centre No. 30 Harbour Road Wanchai Hong Kong Home and Building Control Honeywell Limited-Honeywell Limitée 155 Gordon Baker Road North York, Ontario M2H 3N7 Honeywell Latin American Region 480 Sawgrass Corpor ...

Manufacturer Honeywell Category Dehumidifier

Documents that we receive from a manufacturer of a Honeywell H1008 can be divided into several groups. They are, among others:
- Honeywell technical drawings
- H1008 manuals
- Honeywell product data sheets
- information booklets
- or energy labels Honeywell H1008
All of them are important, but the most important information from the point of view of use of the device are in the user manual Honeywell H1008.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Honeywell H1008, service manual, brief instructions and user manuals Honeywell H1008. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Honeywell H1008.

Similar manuals

A complete manual for the device Honeywell H1008, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Honeywell H1008 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Honeywell H1008.

A complete Honeywell manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Honeywell H1008 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Honeywell H1008, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Honeywell H1008, that we can find in the current document
3. Tips how to use the basic functions of the device Honeywell H1008 - which should help us in our first steps of using Honeywell H1008
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Honeywell H1008
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Honeywell H1008 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Honeywell H1008?

Use the form below

If you did not solve your problem by using a manual Honeywell H1008, ask a question using the form below. If a user had a similar problem with Honeywell H1008 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)