Manual Maxtor 91024D4

71 pages 0.86 mb
Download

Go to site of 71

Summary
  • Maxtor 91024D4 - page 1

    H AR D D R IVE P R ODU C T M AN U A L DiamondMax ™ Plus 5120 92048D8, 91792D7, 91536D6 91280D5, 91024D4, 90750D3 ...

  • Maxtor 91024D4 - page 2

    DiamondMax ™ Plus 5120 92048D8, 91792D7, 91536D6, 91280D5, 91024D4 and 90750D3 All material contained herein Copyright © 1999 Maxtor Corporation. DiamondMax™, DiamondMax™ 4320, DiamondMax™ Plus 2500, DiamondMax™ Plus 5120 and MaxFax™ are trademarks of Maxtor Corporation. No Quibble ® Service is a registered trademark of Maxtor Corpora ...

  • Maxtor 91024D4 - page 3

    Revisions Manual No. 1410 V E R. O N C EN O I T C E SN O I T P I R C S E D E T A D AC 7 5 3 9 7l l A. e s a e l e r l a i t i n I 9 9 / 0 2 / 3 0 ...

  • Maxtor 91024D4 - page 4

    Before Y ou Begin Thank you for your interest in the Maxtor DiamondMax™ Plus 5120 AT hard disk drives. This manual provides technical information for OEM engineers and systems integrators regarding the installation and use of DiamondMax hard drives. Drive repair should be performed only at an authorized repair center. For repair information, cont ...

  • Maxtor 91024D4 - page 5

    DIAMONDMAX PLUS 5120 PRODUCT MANUAL i Contents Section 1 — Introduction Maxtor Corporation 1 - 1 Products 1 - 1 Support 1 - 1 Manual Organization 1 - 1 Abbreviations 1 - 1 Conventions 1 - 2 Key Words 1 - 2 Numbering 1 - 2 Signal Conventions 1 - 2 Section 2 — Product Description The DiamondMax ™ Plus 5120 Product Features 2 - 2 Functional/Inte ...

  • Maxtor 91024D4 - page 6

    DIAMONDMAX PLUS 5120 PRODUCT MANUAL ii Section 3 — Product Specifications Models and Capacities 3 - 1 Drive Configuration 3 - 1 Performance Specifications 3 - 1 Physical Dimensions 3 - 2 Power Requirements 3 - 3 Power Mode Definitions 3 - 3 Spin-up 3 - 3 Seek 3 - 3 Read/Write 3 - 3 Idle 3 - 3 Standby 3 - 3 Sleep 3 - 3 EPA Energy Star Compliance 3 ...

  • Maxtor 91024D4 - page 7

    DIAMONDMAX PLUS 5120 PRODUCT MANUAL iii Ultra Direct Memory Access (UDMA) 4 - 5 OS Requirements for Large Capacity Hard Drives 4 - 5 Hard Drive Identification 4 - 6 Identifying IDE Devices on the Interface 4 - 6 Jumper Settings 4 - 6 Systems Using Cable Select 4 - 6 Relationship to Other IDE Devices 4 - 6 Mounting Drive in System 4 - 7 Attaching In ...

  • Maxtor 91024D4 - page 8

    DIAMONDMAX PLUS 5120 PRODUCT MANUAL iv Device Control Register 6 - 5 Digital Input Register 6 - 5 Reset and Interrupt Handling 6 - 6 Section 7 — Interface Commands Command Summary 7 - 1 Read Commands 7 - 2 Read Sector(s) 7 - 2 Read Verify Sector(s) 7 - 2 Read Sector Buffer 7 - 2 Read DMA 7 - 3 Read Multiple 7 - 3 Set Multiple 7 - 3 Write Commands ...

  • Maxtor 91024D4 - page 9

    DIAMONDMAX PLUS 5120 PRODUCT MANUAL v Figures Figure Title Page 2 - 1 PCBA Jumper Location and Configuration 2 - 6 3 - 1 Outline and Mounting Dimensions 3 - 2 4 - 1 Multi-pack Shipping Container 4 - 2 4 - 2 Single-pack Shipping Container (Option A) 4 - 3 4 - 3 Single-pack Shipping Container (Option B) 4 - 3 4 - 4 Master, Slave and Cable Select Sett ...

  • Maxtor 91024D4 - page 10

    DIAMONDMAX PLUS 5120 – INTRODUCTION 1 – 9 SECTION 1 Introduction Maxtor Corporation Maxtor Corporation has been providing high-quality computer storage products since 1982. Along the way, we’ve seen many changes in data storage needs. Not long ago, only a handful of specific users needed more than a couple hundred megabytes of storage. Today, ...

  • Maxtor 91024D4 - page 11

    DIAMONDMAX PLUS 5120 – INTRODUCTION 1 – 10 Conventions If there is a conflict between text and tables, the table shall be accepted as being correct. Key Words The names of abbreviations, commands, fields and acronyms used as signal names are in all uppercase type (e.g., IDENTIFY DRIVE). Fields containing only one bit are usually referred to as ...

  • Maxtor 91024D4 - page 12

    PRODUCT DESCRIPTION 2 – 1 SECTION 2 Product Description Maxtor DiamondMax™ Plus 5120 AT disk drives are 1-inch high, 3.5-inch diameter random access storage devices which incorporate an on-board ATA-4/Ultra DMA controller. High capacity is achieved by a balanced combination of high areal recording density and the latest data encoding and servo ...

  • Maxtor 91024D4 - page 13

    PRODUCT DESCRIPTION 2 – 2 Product Features Functional / Interface Maxtor DiamondMax™ Plus 5120 hard drives contain all necessary mechanical and electronic parts to interpret control signals and commands from an AT-compatible host computer. See Section 3 Product Specifications, for complete drive specifications. Zone Density Recording The disk c ...

  • Maxtor 91024D4 - page 14

    PRODUCT DESCRIPTION 2 – 3 Logical Block Addressing The Logical Block Address (LBA) mode can only be utilized in systems that support this form of translation. The cylinder, head and sector geometry of the drive, as presented to the host, differs from the actual physical geometry. The host AT computer may access a drive of set parameters: number o ...

  • Maxtor 91024D4 - page 15

    PRODUCT DESCRIPTION 2 – 4 Cache Management Buffer Segmentation The data buffer is organized into two segments: the data buffer and the micro controller scratch pad. The data buffer is dynamically allocated for read and write data depending on the commands received. A variable number of read and write buffers may exist at the same time. Read-Ahead ...

  • Maxtor 91024D4 - page 16

    PRODUCT DESCRIPTION 2 – 5 Major HDA Components Drive Mechanism A brush-less DC direct drive motor rotates the spindle at 7,200 RPM (±0.1%). The dynamically balanced motor/spindle assembly ensures minimal mechanical run-out to the disks. A dynamic brake provides a fast stop to the spindle motor upon power removal. The speed tolerance includes mot ...

  • Maxtor 91024D4 - page 17

    PRODUCT DESCRIPTION 2 – 6 N O I T A R U G I F N O C R E P M U J0 5 J8 4 J6 4 J4 4 J2 4 J e v a l S / r e t s a M * m e t s y s e v i r d e l g n i s n i e v i r d y l n O * m e t s y s e v i r d l a u d n i e v i r d r e t s a M m e t s y s e v i r d l a u d n i e v i r d e v a l S C C O t c e l e S e l b a C * d e l b a s i D d e l b a n E O C n ...

  • Maxtor 91024D4 - page 18

    PRODUCT SPECIFICATIONS 3 – 1 SECTION 3 Product Specifications Models and Capacities Performance Specifications L E D O M8 D 8 4 0 2 97 D 2 9 7 1 96 D 6 3 5 1 95 D 0 8 2 1 94 D 4 2 0 1 93 D 0 5 7 0 9 e c a f r e t n I / r e l l o r t n o C d e t a r g e t n I A M D a r t l U / 4 - A T A d o h t e M g n i d o c n E 7 1 / 6 1 L L R 4 R P E e v a e l ...

  • Maxtor 91024D4 - page 19

    PRODUCT SPECIFICATIONS 3 – 2 Physical Dimensions 1 .028 max [25.9 mm] .25 ± .0 1 1 .1 22 ± .02 [28.4 mm] 1 .638 ± .005 [41 .61 mm] 1 .625 ± .02 4.000 ± .0 1 [1 0 1 .6 mm] 1 .75 ± .02 5.787 max [1 46.6 mm] 6 x 6-32 UNC T ap 4 x 6-32 UNC T ap 4.00 ± .0 1 [1 02.1 mm] 3.75 ± .0 1 [95.25 mm] Figure 3 - 1 Outline and Mounting Dimensions R E T E ...

  • Maxtor 91024D4 - page 20

    PRODUCT SPECIFICATIONS 3 – 3 Power Requirements Power Mode Definitions Spin-up The drive is spinning up following initial application of power and has not yet reached full speed. Seek A random access operation by the disk drive. Read/Write Data is being read from or written to the drive. Idle The drive is spinning, the actuator is parked and powe ...

  • Maxtor 91024D4 - page 21

    PRODUCT SPECIFICATIONS 3 – 4 Reliability Specifications Annual Return Rate < 1.5% Annual Return Rate (ARR) indicates the average against products shipped. ARR includes all reasons for returns (failures, handling damage, NDF), but does not include inventory credit returns. Quality Acceptance Rate < 500 DPPM The quality acceptance rate indica ...

  • Maxtor 91024D4 - page 22

    PRODUCT SPECIFICATIONS 3 – 5 EMC/EMI Radiated Electromagnetic Field Emissions - EMC Compliance The hard disk drive mechanism is designed as a subassembly for installation into a suitable enclosure and is therefore not subject to Subpart J of Part 15 of FCC Rules (47CFR15) or the Canadian Department of Communications Radio Interference Regulations ...

  • Maxtor 91024D4 - page 23

    INSTALLATION 4 – 12 SECTION 4 Handling and Installation Pre-formatted Drive This Maxtor hard drive has been formatted at the factory. Do not use a low-level formatting program. Important Notice There are a number of system BIOS’s currently in use which do not support hard drives with more than 4095 cylinders (2.1 gigabytes). This section contai ...

  • Maxtor 91024D4 - page 24

    INSTALLATION 4 – 13 Unpacking and Inspection Retain any packing material for reuse. Inspect the shipping container for evidence of damage in transit. Notify the carrier immediately in case of damage to the shipping container. As they are removed, inspect drives for evidence of shipping damage or loose hardware. If a drive is damaged (and no conta ...

  • Maxtor 91024D4 - page 25

    INSTALLATION 4 – 14 Figure 4 - 2 Single Pack Shipping Container (Option A) Figure 4 - 3 Single Pack Shipping Container (Option B) Repacking If a Maxtor drive requires return, repack it using Maxtor packing materials, including the antistatic bag. Physical Installation Recommended Mounting Configuration The DiamondMax™ Plus 5120 drive design all ...

  • Maxtor 91024D4 - page 26

    INSTALLATION 4 – 15 1 Before Y ou Begin IMPORTANT – PLEASE READ! Please read this Installation Sheet completely before installing the Maxtor hard drive. It gives general information for installing a Maxtor hard drive in a typical computer system. If you don’t understand the installation steps, have a qualified computer technician install the ...

  • Maxtor 91024D4 - page 27

    INSTALLATION 4 – 16 3 Hard Drive Identification IDE stands for Integrated Drive Electronics and EIDE is Enhanced IDE. The IDE or EIDE interface is designed to support two devices – typically hard drives – on a single ribbon cable through one 40 pin connector on the mother board or interface card. Some mother boards and interface cards may hav ...

  • Maxtor 91024D4 - page 28

    INSTALLATION 4 – 17 4 Mounting Drive in System Turn the computer OFF, disconnect the power cord and remove the cover. Refer to the computer user’s manual for information on removing the cover. Each system manufacturer uses different types of cases, including desktop, mini-tower, full tower and other special configurations. As a result, there ar ...

  • Maxtor 91024D4 - page 29

    INSTALLATION 4 – 18 5 Attaching Interface and Power Cables In order for the computer to recognize that the Maxtor hard drive is in the system, the power cable and IDE interface cable must be properly connected. 1 Attach an available IDE interface connector to J1 on the Maxtor hard drive. The striped or colored edge of the IDE interface cable indi ...

  • Maxtor 91024D4 - page 30

    INSTALLATION 4 – 19 7 System Setup The following procedures are designed for systems using the DOS 5.0 (or higher), Windows 95 and Windows 98 operating systems. For other operating systems (e.g., Windows NT, OS2, UNIX, LINUX and Novell NetWare), refer to the operating system user’s manual for the BIOS setting and other installation requirements ...

  • Maxtor 91024D4 - page 31

    INSTALLATION 4 – 20 Set the Cylinder, Head and Sector values with the values listed on the drive label. The drive label is located on the top cover of the drive. The fields LZone (Landing Zone) and WPcom (Write Pre-comp) are not used by the Maxtor hard drive. These fields may be set to 0 or by the values assigned by the BIOS. Note : Each BIOS man ...

  • Maxtor 91024D4 - page 32

    INSTALLATION 4 – 21 3 If the BIOS was set to AUTO DETECT, follow the instructions in Section 7 to prepare the hard drive using the MaxBlast installation software. If other BIOS settings were used, access the system BIOS SETUP program and set the parameters to a User Definable Type with 4,092 cylinders, 16 heads and 63 sectors per track for the Ma ...

  • Maxtor 91024D4 - page 33

    AT INTERFACE DESCRIPTION 5 – 22 SECTION 5 AT Interface Description Interface Connector All DiamondMax™ Plus 5120 AT drives have a 4 0- pin ATA interface connector mounted on the PCBA. The drive may connect directly to the host; or it can also accommodate a cable connection (max cable length: 18 inches). Figure 5 - 1 Data Connector Pin Descripti ...

  • Maxtor 91024D4 - page 34

    AT INTERFACE DESCRIPTION 5 – 23 Pin Description Table PIN NAME PIN I/O SIGNAL NAME SIGNAL DESCRIPTION RESET - 01 I Host Reset Reset signal from the host system. Active during power up and inactive after. DD0 17 I/O Host Data Bus 16 bit bi-directional data bus between host and drive. Lower 8 bits used for register and ECC byte transfers. All 16 bi ...

  • Maxtor 91024D4 - page 35

    AT INTERFACE DESCRIPTION 5 – 24 TIMING PARAMETERS MODE 0 MODE 1 MODE 2 MODE 3 MODE 4 t0 Cycle Time (min) 600 ns 383 ns 240 ns 180 ns 120 ns t1 Address valid to DIOR-/DIOW- setup (min) 70 ns 50 ns 30 ns 30 ns 25 ns t2 DIOR-/DIOW- 16-bit (min) 165 ns 125 ns 100 ns 80 ns 70 ns t2i DIOR-/DIOW- recovery time (min) 70 ns 25 ns t3 DIOW- data setup (min) ...

  • Maxtor 91024D4 - page 36

    AT INTERFACE DESCRIPTION 5 – 25 DMA Timing TIMING PARAMETERS MODE 0 MODE 1 MODE 2 t0 Cycle Time (min) 480 ns 150 ns 120 ns tC DMACK to DMARQ delay tD DIOR-/DIOW- (min) 215 ns 80 ns 70 ns tE DIOR- data access (min) 150 ns 60 ns tF DIOR- data hold (min) 5 ns 5 ns 5 ns tG DIOR-/DIOW- data setup (min) 100 ns 30 ns 20 ns tH DIOW- data hold (min) 20 ns ...

  • Maxtor 91024D4 - page 37

    AT INTERFACE DESCRIPTION 5 – 26 Ultra DMA Timing TIMING PARAMETERS (all times in nanoseconds) MODE 0 MODE 1 MODE 2 MIN MAX MIN MAX MIN MAX t CYC Cycle Time (from STROBE edge to STROBE edge) 114 75 55 t2 CYC Two cycle time (from rising edge to next rising edge or from falling edge to next falling edge of STROBE ) 235 156 117 t DS Data setup time ( ...

  • Maxtor 91024D4 - page 38

    AT INTERFACE DESCRIPTION 5 – 27 Figure 5 - 5 Sustained Ultra DMA Data In Burst t DVH DSTROBE at device DD(15:0) at device DSTROBE at host DD(15:0) at host t DVH t CYC t CYC t DVS t DVS t DH t DS t DH t DS t 2CYC t DH t DVH t 2CYC DMARQ (device) DMACK- (host) STOP (host) HDMARDY- (host) DSTROBE (device) DD(15:0) (device) t SR t RFS t RP Figure 5 - ...

  • Maxtor 91024D4 - page 39

    AT INTERFACE DESCRIPTION 5 – 28 t AZ t IORDYZ CRC DMARQ (device) DMACK- (host) STOP (host) HDMARDY- (host) DSTROBE (device) DD(15:0) DA0, DA1, DA2, CS0-, CS1- t ACK t LI t MLI t DVS t LI t ACK t ACK t ZAH t DVH t SS t LI Figure 5 - 7 Device Terminating an Ultra DMA Data In Burst t DVH CRC t AZ DMARQ (device) DMACK- (host) STOP (host) HDMARDY- (ho ...

  • Maxtor 91024D4 - page 40

    AT INTERFACE DESCRIPTION 5 – 29 t DH t DS t DVH HSTROBE at host DD(15:0) at host HSTROBE at device DD(15:0) at device t DVH t CY C t CYC t DVS t DVS t DS t DH t 2CYC t DH t DVH t 2CYC DMARQ (device) DMACK- (host) STOP (host) DDMARDY- (device) HSTROBE (host) DD(15:0) (host) DA0, DA1, DA2, CS0-, CS1- t UI t ACK t ENV t ZIORDY t LI t DVS t DVH t ACK ...

  • Maxtor 91024D4 - page 41

    AT INTERFACE DESCRIPTION 5 – 30 DMARQ (device) DMACK- (host) STOP (host) DDMARDY- (device) HSTROBE (host) DD(15:0) (host) t SR t RFS t RP Figure 5 - 11 Device Pausing an Ultra DMA Data Out Burst DMARQ (device) DMACK- (host) STOP (host) DDMARDY- (device) HSTROBE (host) DD(15:0) (host) DA0, DA1, DA2, CS0-, CS1- t ACK t LI t MLI t DVS t LI t LI t AC ...

  • Maxtor 91024D4 - page 42

    AT INTERFACE DESCRIPTION 5 – 31 DMARQ (device) DMACK- (host) STOP (host) DDMARDY- (device) HSTROBE (host) DD(15:0) (host) DA0, DA1, DA2, CS0-, CS1- t ACK t MLI t DVS t LI t LI t ACK CRC t DVH t ACK t IORDYZ t MLI t RP t RFS Figure 5 - 13 Device Terminating an Ultra DMA Data Out Burst ...

  • Maxtor 91024D4 - page 43

    HOST SOFTWARE INTERFACE 6 – 1 SECTION 6 Host Software Interface The host communicates with the drive through a set of controller registers accessed via the host’s I/O ports. These registers divide into two groups: the Task File, used for passing commands and command parameters and the Control/Diagnostic registers. Task File Registers The Task F ...

  • Maxtor 91024D4 - page 44

    HOST SOFTWARE INTERFACE 6 – 2 Sector Count Register Holds the number of sectors to be sent during a Read or Write command, and the number of sectors per track during a Format command. A value of zero in this register implies a transfer of 256 sectors. A multi- sector operation decrements the Sector Count register. If an error occurs during such a ...

  • Maxtor 91024D4 - page 45

    HOST SOFTWARE INTERFACE 6 – 3 Command Register Contains code for the command to be performed. Additional command information should be written to the task file before the Command register is loaded. When this register is written, the BUSY bit in the Status register sets, and interrupt request to the host clears; invalid commands abort. (Detailed ...

  • Maxtor 91024D4 - page 46

    HOST SOFTWARE INTERFACE 6 – 4 COMMAND NAME COMMAND CODE PARAMETERS USED b7 b6 b5 b4 b3 b2 b1 b0 F SC SN C SDH Recalibrate 0 0 0 1 xxxx N N N N D Read Sector(s) 0 0 1 0 0 0 L x N Y Y Y Y Read DMA 1 1 0 0 1 0 0 x N Y Y Y Y Write Sector(s) 0 0 1 1 0 0 L x N Y Y Y Y Write DMA 1 1 0 0 1 0 1 x N Y Y Y Y Write Verify Sector(s) 0 0 1 1 1 1 0 0 N Y Y Y Y ...

  • Maxtor 91024D4 - page 47

    HOST SOFTWARE INTERFACE 6 – 5 Control Diagnostic Registers These I/O port addresses reference three Control/Diagnostic registers: I/O PORT READ WRITE 3F6h Alternate Status Fixed Disk Control 3F7h Digital Input Not used Alternate Status Register Contains the same information as the Status register in the Task File. However, this register may be re ...

  • Maxtor 91024D4 - page 48

    HOST SOFTWARE INTERFACE 6 – 6 Reset and Interrupt Handling Reset Handling One of three different conditions may cause a reset: power on, hardware reset or software reset. All three cause the interface processor to initialize itself and the Task File registers of the interface. A reset also causes a set of the Busy bit in the Status register. The ...

  • Maxtor 91024D4 - page 49

    INTERFACE COMMANDS 7 – 1 SECTION 7 Interface Commands The following section describes the commands (and any parameters necessary to execute them), as well as Status and Error register bits affected. Read Commands Read Sector(s) Read Verify Sector(s) Read Sector Buffer Read DMA Multi-word DMA Ultra DMA Read Multiple Set Multiple Write Commands Wri ...

  • Maxtor 91024D4 - page 50

    INTERFACE COMMANDS 7 – 2 Read Commands Read Sector(s) Reads from 1 to 256 sectors, as specified in the Command Block, beginning at the specified sector. (A sector count of 0 requests 256 sectors.) Immediately after the Command register is written, the drive sets the BSY bit and begins execution of the command. If the drive is not already on the d ...

  • Maxtor 91024D4 - page 51

    INTERFACE COMMANDS 7 – 3 Read DMA Multi-word DMA Identical to the Read Sector(s) command, except that 1. The host initializes a slave-DMA channel prior to issuing the command, 2. Data transfers are qualified by DMARQ and are performed by the slave-DMA channel and 3. The drive issues only one interrupt per command to indicate that data transfer ha ...

  • Maxtor 91024D4 - page 52

    INTERFACE COMMANDS 7 – 4 Set Multiple Mode Enables the controller to perform Read and Write Multiple operations, and establishes the block count for these commands. Before issuing this command, the Sector Count register should be loaded with the number of sectors per block. The drives support block sizes of 2, 4, 8 and 16 sectors. When this comma ...

  • Maxtor 91024D4 - page 53

    INTERFACE COMMANDS 7 – 5 Write Multiple Performs similarly to the Write Sector(s) command, except that: 1. The controller sets BSY immediately upon receipt of the command, 2. Data transfers are multiple sector blocks and 3. The Long bit and Retry bit is not valid. Command execution differs from Write Sector(s) because: 1. Several sectors transfer ...

  • Maxtor 91024D4 - page 54

    INTERFACE COMMANDS 7 – 6 Set Feature Commands Set Features Mode Enables or disables features supported by the drive. When the drive receives this command it: 1. Sets BSY, 2. Checks the contents of the Features register, 3. Clears BSY and 4. Generates an interrupt. If the value of the register is not a feature supported by the drive, the command i ...

  • Maxtor 91024D4 - page 55

    INTERFACE COMMANDS 7 – 7 Power Mode Commands Standby Immediate – 94h/E0h Spin down and do not change time out value. This command will spin the drive down and cause the drive to enter the STANDBY MODE immediately. If the drive is already spun down, the spin down sequence is not executed. Idle Immediate – 95h/E1h Spin up and do not change time ...

  • Maxtor 91024D4 - page 56

    INTERFACE COMMANDS 7 – 8 When enabling the Automatic Power Down sequence, the value placed in the Sector Count register is multiplied by five seconds to obtain the Time-out Interval value. If no drive commands are received from the host within the Time-out Interval, the drive automatically enters the STANDBY mode. The minimum value is 5 seconds. ...

  • Maxtor 91024D4 - page 57

    INTERFACE COMMANDS 7 – 9 Initialization Commands Identify Drive Allows the host to receive parameter information from the drive. When the command is received, the drive: 1. Sets BSY, 2. Stores the required parameter information in the sector buffer, 3. Sets the DRQ bit and 4. Generates an interrupt. The host may then read the information out of t ...

  • Maxtor 91024D4 - page 58

    INTERFACE COMMANDS 7 – 10 WORD CONTENT DESCRIPTION 50 Reserved 51 15-8 = PIO data transfer mode 7-0 = not used 52 15-8 = DMA data transfer mode 7-0 = not used 53 15 = reserved 2, 1 = the fields supported in words 88 are valid, 0 = the fields supported in words 88 are not valid 1, 1 = the fields reports in words 64-70 are valid, 0 = the fields rep ...

  • Maxtor 91024D4 - page 59

    INTERFACE COMMANDS 7 – 11 WORD CONTENT DESCRIPTION 83 Command sets supported. If words 82, 83 and 84 = 0000h or FFFFh command set notification not supported. 15 = shall be cleared to zero 14 = shall be set to one 13-1 = reserved 0, 1 = supports Download Microcode command 84 Command set extensions supported. If words 84, 85 and 86 = 0000h or FFFFh ...

  • Maxtor 91024D4 - page 60

    INTERFACE COMMANDS 7 – 12 Initialize Drive Parameters Enables the drive to operate as any logical drive type. The drive will always be in the translate mode because of Zone Density Recording, which varies the number of sectors per track depending on the zone. Through setting the Sector Count Register and Drive Head Register, this command lets the ...

  • Maxtor 91024D4 - page 61

    INTERFACE COMMANDS 7 – 13 Seek, Format and Diagnostic Commands Seek Initiates a seek to the track, and selects the head specified in the Command block. 1. Sets BSY in the Status register, 2. Initiates the Seek, 3. Resets BSY and 4. Generates an interrupt. The drive does not wait for the seek to complete before returning the interrupt. If a new co ...

  • Maxtor 91024D4 - page 62

    INTERFACE COMMANDS 7 – 14 S.M.A.R.T. Command Set Execute S.M.A.R.T. The Self-Monitoring Analysis and Reporting Technology (S.M.A.R.T.) command has been implemented to improve the data integrity and data availability of hard disk drives. In some cases, a S.M.A.R.T. capable device will predict an impending failure with sufficient time to allow user ...

  • Maxtor 91024D4 - page 63

    SERVICE AND SUPPORT 8 – 1 SECTION 8 Service and Support Service Policy Repairs to any DiamondMax™ Plus 5120 drive should be made only at an authorized Maxtor repair facility. Any unauthorized repairs or adjustments to the drive void the warranty. To consistently provide our customers with the best possible products and services, Maxtor develope ...

  • Maxtor 91024D4 - page 64

    SERVICE AND SUPPORT 8 – 2 MaxFax ™ Service Use a touch-tone phone to order Technical Reference Sheets, Drive Specifications, Installation Sheets and other documents from our 24-hour automated fax retrieval system. Requested items are sent to your fax machine. U.S. and Canada Language support: English, Spanish Phone 800-2MAXTOR, listen for optio ...

  • Maxtor 91024D4 - page 65

    GLOSSARY GL – 1 GLOSSAR Y Glossary A ACCESS To obtain data from, or place data into, RAM, a register, or data storage device. ACCESS TIME The interval between the issuing of an access command and the instant that the target data may be read or written. Access time includes seek time, latency and controller overhead time. ADDRESS A number, general ...

  • Maxtor 91024D4 - page 66

    GLOSSARY GL – 2 CYLINDER On several disk surfaces sharing a common rotational axis, the aggregate of tracks at a given radial position. A set of disk tracks that are simultaneously under the set of read/ write heads. This three-dimensional storage volume can be accessed after a single seek. CYLINDER ZERO The outermost cylinder in a drive that can ...

  • Maxtor 91024D4 - page 67

    GLOSSARY GL – 3 FILE ALLOCATION TABLE (FAT) Allocates space on the disk for files, one cluster at a time; locks out unusable clusters; identifies unused (free) area; and lists a file’s location. With two FAT’s present, the second copy ensures consistency and protects against loss of data if one of the sectors on the first FAT is damaged. FLUX ...

  • Maxtor 91024D4 - page 68

    GLOSSARY GL – 4 LOGICAL ADDRESS A storage location address that may not relate directly to a physical location. Usually used to request information from a controller, which performs a logical to physical address conversion, and in turn, retrieves the data from a physical location in the mass storage peripheral. LOGICAL BLOCK ADDRESSING Defines th ...

  • Maxtor 91024D4 - page 69

    GLOSSARY GL – 5 R RANDOM ACCESS MEMORY (RAM) Memory designed so that any storage location can be accessed randomly, directly and individually. This is contrasted to sequential access devices such as tape drives. READ To access a storage location and obtain previously recorded data. To sense the presence of flux reversals on magnetic media. Usuall ...

  • Maxtor 91024D4 - page 70

    GLOSSARY GL – 6 T THIN-FILM HEAD A magnetic transducer manufactured by deposition of magnetic and electrical materials on a base material contrasted with prior art mechanical methods. Read/write heads whose read/write element is deposited using integrated circuit techniques rather than being manually wound. THIN-FILM MEDIA See plated thin film me ...

  • Maxtor 91024D4 - page 71

    M AXT OR C ORPORA TION 510 C OTT ONW OOD D RIVE M ILPIT AS ,C ALIFORNIA 95035 ...

Manufacturer Maxtor Category Computer Drive

Documents that we receive from a manufacturer of a Maxtor 91024D4 can be divided into several groups. They are, among others:
- Maxtor technical drawings
- 91024D4 manuals
- Maxtor product data sheets
- information booklets
- or energy labels Maxtor 91024D4
All of them are important, but the most important information from the point of view of use of the device are in the user manual Maxtor 91024D4.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Maxtor 91024D4, service manual, brief instructions and user manuals Maxtor 91024D4. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Maxtor 91024D4.

Similar manuals

A complete manual for the device Maxtor 91024D4, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Maxtor 91024D4 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Maxtor 91024D4.

A complete Maxtor manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Maxtor 91024D4 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Maxtor 91024D4, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Maxtor 91024D4, that we can find in the current document
3. Tips how to use the basic functions of the device Maxtor 91024D4 - which should help us in our first steps of using Maxtor 91024D4
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Maxtor 91024D4
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Maxtor 91024D4 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Maxtor 91024D4?

Use the form below

If you did not solve your problem by using a manual Maxtor 91024D4, ask a question using the form below. If a user had a similar problem with Maxtor 91024D4 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)