Manual Raritan Engineering Crown Head II

16 pages 0.37 mb
Download

Go to site of 16

Summary
  • Raritan Engineering Crown Head II - page 1

    crown head II ™ ELECTRIC MARINE TOILET OPERATION, MAINTENANCE, and INSTALLATION INSTRUCTIONS Manufactured after June 2002 THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND FOLLOWED DURING BOTH INSTALLATION AND OPERATION. WARNING: Raritan Engineering Company, Inc. recommends that a qualified person or electrician install this product. ...

  • Raritan Engineering Crown Head II - page 2

    • Push Button Switch (#164000) Press and hold switch until all waste is cleared from bowl. NOTE: Push Button Switch flushing is shown. Refer to manuals included with Toilet Control (TC12W), Raritime Solid State Timer with Solenoid (#RTC), or Flush Control (#SWF100) for operation Instructions. • No special toilet paper is required. • Water sho ...

  • Raritan Engineering Crown Head II - page 3

    MAINTENANCE Cleaning Instructions IMPORTANT: Do not use cleaners that contain ammonia, ethyl acetate, phosphoric acid or concentrated chlorine bleach. These will cause damage to the toilet. Using C.P. (#1PCP22), a bio-enzymatic toilet bowl cleaner (available from Raritan Engineering), will keep the bowl clean and fresh smelling. Recommend Visual In ...

  • Raritan Engineering Crown Head II - page 4

    WINTERIZING IMPORTANT • Improper winter lay up is a major cause of marine toilet failure. • Use only nontoxic antifreeze. • Flush toilet several times to clear waste from system. • Dispose of all antifreeze in accordance with local and federal regulations. • Winterize holding tanks, plumbing, treatment systems (MSD’s), etc. independentl ...

  • Raritan Engineering Crown Head II - page 5

    Pressurized Fresh Water Model Parts Required • 1 1/2" (38mm) I.D. hose, approximately 3 feet (1m) long • Two buckets • Nontoxic antifreeze approximately 1 quart (1 liter) Steps 1. Close discharge seacock 2. Shut off intake water at source. 3. Turn off power to unit. 4. Disconnect and drain discharge hose. 5. Disconnect intake hoses from ...

  • Raritan Engineering Crown Head II - page 6

    INSTALLATION Parts Included All Toilets Toilet Bowl (Household or Marine) Seat and Cover Discharge pump assembly Heavy Duty Push Button Switch (#164000) Mounting pads Lower Motor Cover Sea Water Model Remote Intake Pump 3/4" Hose Barb straight fitting 3/4" Hose Barb - 90° elbow fitting Plug Fitting In-Line Strainer with fittings 3/4" ...

  • Raritan Engineering Crown Head II - page 7

    SPECIFICATIONS Base Depth: 10 7/8" (27.6cm) Height: 17 3/8" (44.1cm) Household 17" (43.2cm) Marine Base Width: 10 1/2" (26.8cm) Bowl Width: 14 3/8" (36.6cm) Household 13" (33cm) Marine Bowl Depth: 19 1/4" (48.9cm) Household 16 3/4" (42.6cm) Marine Plumbing Maximum suction of Intake pump (Maximum height above ...

  • Raritan Engineering Crown Head II - page 8

    Mounting T oilet Mounting surface must be flat and solid. IMPORTANT: Do not mount where it may be subject to shower spray or other sources of external water. 1. Install seat on toilet. 2. Place toilet where it will be located. Make sure there is room to route hoses. Make sure seat will open properly. 3. Mark location of toilet base mounting holes o ...

  • Raritan Engineering Crown Head II - page 9

    Mounting Atmospheric Vacuum Breaker (Pressurized Freshwater Model only) 1. Install fittings as shown. 2. Locate mounting area that is a minimum of 6" (15.3cm) above toilet. 3. Secure where top is in horizontal position. Mounting In-Line Strainer (Seawater Models Only) Make sure strainer bowl is tight. 1. Locate strainer where it will be access ...

  • Raritan Engineering Crown Head II - page 10

    INSTALLATION PLUMBING WARNING: Hazard of Flooding Toilets mounted at or below the waterline must have a vented loop installed in the discharge line. The top of the vented loop must be a minimum of 4" (10cm) above the waterline at the boats greatest angle of heel (see vented loop manufacturer’s instructions). Sea Water Models must also have a ...

  • Raritan Engineering Crown Head II - page 11

    Intake Lines Pressurized Freshwater Models Install a shut off valve in intake line before water solenoid valve. 1 . Connect hose from pressurized freshwater source to a shut off valve. 2. Connect hose from shut off valve to inlet port of water solenoid valve. NOTE: To avoid malfunction of water solenoid due to debris in water, installation of Fresh ...

  • Raritan Engineering Crown Head II - page 12

    WIRING WIRING WARNING: Hazard of Shock and Fire • Always use proper wire, wire connectors and fuse/circuit breaker. See Specification Chart on page 7. • Secure wire properly. • Do not connect other appliances to toilet circuit. • Make sure power is off before proceeding. NOTE: Figures shown with installation of Push Button Switch (#164000). ...

  • Raritan Engineering Crown Head II - page 13

    Problem Possible Cause A1. Clogged or restricted discharge line. A2. Too many bends or ells in discharge line. A3. Clogged holding tank or vented loops. A4. Mineral buildup in hoses and fittings. A5. Low voltage. A6. Damage to pump wall. A7. Full holding tank. B1. Head not level. B2. Restriction in line to Intake Pump or clogged strainer. B3. Intak ...

  • Raritan Engineering Crown Head II - page 14

    Part # Description 1118 Lockwasher (4) 1222AW 90 Degree discharge (opt.) 1222B Straight discharge 1226B 1/4" - 20 S/S Hex Nut (4) 1234 Bowl Gasket 1236AW Bowl Spud Assembly 1236E Bowl Elbow 1237W Marine-size Bowl Assembly (White) (Not shown) 1238A Marine-size Seat and Cover (White) (Not shown) 1244AW Household-style Bowl Assembly, (Bone) inclu ...

  • Raritan Engineering Crown Head II - page 15

    C2M* CH55 CH92 1341 1222AW CH57 CH59 1234 CH38 1226B 1236E 1236AW 1237W, 1244AW, 1244W C246, 247 F149VT C250 CH26 CH18W CH121 CH120 F149VT CH119MW CH27 C290 1222B CH58 CH51 1118 M30 M31 161107 C253 CROWN HEAD II - EXPLODED PARTS VIEW CR1 CH34 RNI PLA14 CWPS*A PLA14 CH15DD 162410 162425 162100W 162200W 162415 162425 F162VT M23A F144 162425 162405 16 ...

  • Raritan Engineering Crown Head II - page 16

    530 Orange Street, Millville, NJ 08332 USA Telephone: 856-825-4900 FAX: 856-825-4409 www.raritaneng.com Southern Office and Plant: 3101 SW Second Avenue, Fort Lauderdale, FL 33315 USA Telephone: 954-525-0378 FAX: 954-764-4370 L339 0407kgs Specifications Subject to Change Without Notice Printed in U.S.A. LIMITED WARRANTY Raritan Engineering Company ...

Manufacturer Raritan Engineering Category Marine Sanitation System

Documents that we receive from a manufacturer of a Raritan Engineering Crown Head II can be divided into several groups. They are, among others:
- Raritan Engineering technical drawings
- Crown Head II manuals
- Raritan Engineering product data sheets
- information booklets
- or energy labels Raritan Engineering Crown Head II
All of them are important, but the most important information from the point of view of use of the device are in the user manual Raritan Engineering Crown Head II.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Raritan Engineering Crown Head II, service manual, brief instructions and user manuals Raritan Engineering Crown Head II. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Raritan Engineering Crown Head II.

A complete manual for the device Raritan Engineering Crown Head II, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Raritan Engineering Crown Head II by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Raritan Engineering Crown Head II.

A complete Raritan Engineering manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Raritan Engineering Crown Head II - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Raritan Engineering Crown Head II, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Raritan Engineering Crown Head II, that we can find in the current document
3. Tips how to use the basic functions of the device Raritan Engineering Crown Head II - which should help us in our first steps of using Raritan Engineering Crown Head II
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Raritan Engineering Crown Head II
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Raritan Engineering Crown Head II in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Raritan Engineering Crown Head II?

Use the form below

If you did not solve your problem by using a manual Raritan Engineering Crown Head II, ask a question using the form below. If a user had a similar problem with Raritan Engineering Crown Head II it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)