  • Crown 29PT9467S - page 1

    ■ Cast iron sectional heat exchanger and push nipples ■ Vertical flue design ■ Easily assembled with short individual draw rods ■ Optional tankless heater for domestic hot water ■ T op or rear vent connections ■ Side clean out plates ■ Optional Return T emperature Control (RTC) ■ Sizes from 342,000 to 1,852,000 BTU/hr output Heat e ...

  • Crown 29PT9467S - page 2

    1. Opti mum f or la rge i nstal latio ns – Av ailabl e in t en siz es fro m 342, 000 to 1,852, 000 BT U/hr o utput. 2. Gas, oil or co mbina tion gas/o il fi red – Custom er ’s prefe rence in the choic e of fuels for e conomy and a vailab ility may be an im portan t part of th e purc hase d ecisio n. 3. Hot water or s team – The Se ries 2 4 ...

  • Crown 29PT9467S - page 3

    Standard Equipment All Boilers – Sections unassembled, flush insulated jacket, burner mounting plate, burner adapter plate, rear flue damper (top outlet optional), flue canopy , rear observation port cover , target wall (V -903A), and miscellaneous plugs, bushings and fittings. Steam T rim – 15 PSI safety valve, L404A pressuretrol, gauge gl ...

  • Crown 29PT9467S - page 4

    Series 24 Dimensions (in inches) SAFETY/RELIEF VAL VE ‘F’ O.D. COLLAR (STD. REAR OUTLET) 3 ‘C’ ‘A ’ 4 ‘D’ INSULATED JACKET COMBINATION LABEL RATING LABEL � HIGH PRESSURE LIMI T CONTROL/MR � HIGH PRESSURE LIMI T CONTROL/MR NWL 57 MM#67 LWCO LOWEST PERMISSIBLE W A TER LEVEL PLATE (STEAM ON LY) FLOOR FRONT VIEW (STEAM) LEFT SIDE VI ...

  • Crown 29PT9467S - page 5

    Burn er M ounti ng P late s and Ada pter Pla tes FRONT VIEW SIDE VIEWS 4” STANDARD IDENTIFICATION NUMBER ‘A’ DIA HOLE ‘B’ DIA BOLT CIRCLE ‘C’ (REF) 4 8 8” EXTENDED CAST IRON BURNER MOUNTING PLA TES ST ANDARD BURNER ADAPTER PLA TE I.D. ‘A ’ ‘B’ ‘C’ BOILER MODEL P ART NO. NO. DIA. DIA. REF . 24-03 THRU 24-05 330400 920 4-3 ...

  • Crown 29PT9467S - page 6

    Series 24 Minimum Piping Recommendations – W ater Boiler Recommendation 1 is used when the load is constant and not varied due to mixing or multiple zones. Use when: ■ system return water is not less than 135° F for prolonged periods of time ■ system flow does not impact flow through the boiler DRAIN V AL VE (SEE NOTE 4) 24-03 THRU 24-1 1 ...

  • Crown 29PT9467S - page 7

    Re com me nda ti on 3 is use d w hen the re tur n w ate r te mpe rat ure go es belo w 1 35° F f or pro lon ged per iod s o f tim e. This is also pr ima ry- sec ond ary pip ing , b ut inc lud es t he add iti on of a 3- way va lve , r etu rn wate r s ens or and boi ler -mo unte d R TC Re tur n T em pera tur e C ont rol . RETURN PIPING SIZE (IN) SUPP ...

  • Crown 29PT9467S - page 8

    Series 24 Specifications BURNER HEA TING WA TER BOILER W EIGH T NET I=B=R RA TING INPUT SURFACE NET PRES SURE CONTE NT w/ WA TER GROSS (SQ. FT .) FIREBOX IN (GAL.) (LBS.) VENT BOILER HORSE- OUTPUT SQ. FT . MBH MBH OIL GAS VOLUME FIREBOX DIA. MODEL POWER (MBH) STEAM STEAM WA TER (GPH) (MBH) STEAM W A TER (CU. FT .) (“W.C.”) STEAM W A TER STEAM ...

Manufacturer Crown Category Boiler

Documents that we receive from a manufacturer of a Crown 29PT9467S can be divided into several groups. They are, among others:
- Crown technical drawings
- 29PT9467S manuals
- Crown product data sheets
- information booklets
- or energy labels Crown 29PT9467S
All of them are important, but the most important information from the point of view of use of the device are in the user manual Crown 29PT9467S.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Crown 29PT9467S, service manual, brief instructions and user manuals Crown 29PT9467S. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Crown 29PT9467S.

Similar manuals

A complete manual for the device Crown 29PT9467S, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Crown 29PT9467S by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Crown 29PT9467S.

A complete Crown manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Crown 29PT9467S - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Crown 29PT9467S, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Crown 29PT9467S, that we can find in the current document
3. Tips how to use the basic functions of the device Crown 29PT9467S - which should help us in our first steps of using Crown 29PT9467S
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Crown 29PT9467S
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Crown 29PT9467S in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Crown 29PT9467S?

Use the form below

If you did not solve your problem by using a manual Crown 29PT9467S, ask a question using the form below. If a user had a similar problem with Crown 29PT9467S it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)